• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7613-0AB10-0CF0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7613-0AB10-0CF0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7613-0AB10-0CF0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7613-0AB10-0CF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, offering a compact and rugged all-in-one solution for process visualization and control.

    The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is designed for 24 V DC supply voltage. The fanless or low-noise design and industrial-grade components ensure reliable continuous operation.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust PC-based HMI platform is required. It is suitable for integration into control cabinets or machine panels and is commonly deployed in automotive production lines, chemical processing plants, and packaging machinery. Its compatibility with standard PC software and Siemens SIMATIC software makes it a flexible platform for both visualization and data acquisition applications.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 px (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Input Voltage 24 V DC
    Processor Intel Celeron
    Operating System Windows XP / Windows 2000
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM ports)
    IP Protection Rating IP65 (front panel)
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL
    Series/Product Family SIMATIC Panel PC 670

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly, possibly due to corrupted system files or a failed storage device.
    Check the hard disk or CompactFlash card for errors. Attempt system recovery or reinstall the operating system.
    Event ID: 1000
    Application fault — the HMI or SCADA application (e.g. WinCC) has crashed unexpectedly.
    Review the Windows Event Viewer for details. Reinstall or repair the affected application. Check for software version compatibility.
    Event ID: 7034
    Service terminated unexpectedly — a critical Windows service required by the HMI software has stopped.
    Restart the service via Windows Service Manager. If recurring, check for software conflicts or corrupted service files.
    WinCC Runtime Error
    WinCC Runtime has encountered a configuration or communication error and cannot start or maintain a connection to the PLC.
    Verify the project configuration, check network/communication settings, and ensure the PLC is reachable on the configured interface.
    Hardware Watchdog Timeout
    The system watchdog has triggered a reset due to the CPU becoming unresponsive, often caused by software hang or overload.
    Investigate running processes for high CPU usage. Optimize the HMI application and reduce background tasks.
    Display Driver Error
    The graphics driver has failed or become unresponsive, resulting in a blank or distorted display.
    Reinstall or update the display driver. If the display remains blank, check the backlight inverter and display cable connections.
    Network Communication Lost
    The Ethernet connection to the controller or network has been interrupted.
    Check Ethernet cable and switch/hub connections. Verify IP address configuration and ensure no IP conflicts exist on the network.
    Storage Device Failure
    The internal hard disk or CompactFlash storage device has failed or is reporting errors.
    Replace the internal storage device. Restore the system image from a backup. Consider using an industrial-grade CompactFlash card for improved reliability.

    Frequently Asked Questions

    What operating systems are supported by the SIMATIC Panel PC 670 (6AV7613-0AB10-0CF0)?

    The SIMATIC Panel PC 670 supports Windows XP Professional and Windows 2000, which are the operating systems validated by Siemens for use with this hardware platform and SIMATIC software.

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to run Siemens SIMATIC WinCC and other PC-based HMI software from the SIMATIC software family. Compatibility depends on the specific WinCC version and the installed operating system.

    What is the supply voltage for the 6AV7613-0AB10-0CF0?

    The unit operates on a 24 V DC supply voltage, which is standard for industrial panel PCs in the SIMATIC family.

    What is the front panel protection rating of this Panel PC?

    The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for use in industrial environments.

    Can the internal storage device be replaced or upgraded?

    Yes, the internal storage (hard disk or CompactFlash card) can be replaced. It is recommended to use industrial-grade storage media to ensure reliability in continuous operation environments.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power input connector. Verify that the power LED is illuminated. Test the backlight by observing the display in a darkened environment for a faint image.

    If power is confirmed but display is blank, replace the backlight inverter or the display unit. If no power LED, check fuses and the 24 V DC supply source.

    Touch screen does not respond or is inaccurate

    Check if the touch screen is physically damaged or contaminated. Verify that the touch screen driver is correctly installed in the operating system.

    Clean the touch screen surface. Recalibrate the touch screen using the Windows calibration utility. If unresponsive, reinstall the touch screen driver or replace the touch screen overlay.

    System fails to boot or continuously restarts

    Listen for hard disk activity during boot. Connect an external monitor if possible to observe BIOS or boot error messages. Check the Windows Event Log if the system partially boots.

    Replace the internal hard disk or CompactFlash card and restore the system image from a backup. Reseat RAM modules and check all internal connectors for secure contact.

    Loss of communication with PLC or network devices

    Check the Ethernet cable and verify link LEDs on the RJ45 port. Use the Windows network diagnostics to ping the target PLC or device. Verify IP address and subnet mask configuration.

    Replace the Ethernet cable if faulty. Reconfigure the IP address settings to match the network. If the onboard NIC is faulty, consider using a USB-to-Ethernet adapter as a temporary measure and arrange for hardware repair.

    WinCC Runtime application crashes or freezes

    Review the Windows Event Viewer for application error entries. Check CPU and RAM usage via Task Manager during normal operation. Verify that the WinCC project version is compatible with the installed runtime version.

    Increase virtual memory allocation if RAM usage is high. Reinstall or repair the WinCC Runtime installation. Ensure the project file is not corrupted by restoring from a known-good backup.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart