
Siemens 6AV7613-0AB10-0CE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AB10-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface applications, combining a built-in display with a full PC architecture running a Windows-based operating system. This unit is intended for use as a high-performance operator station in industrial automation environments.
The SIMATIC Panel PC 670 6AV7613-0AB10-0CE0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch-sensitive screen for operator interaction. The unit is built around an industrial-grade processor with onboard RAM and a compact flash or hard disk storage option, providing a stable computing platform for SCADA, visualization, and control applications. It supports communication via standard Ethernet (RJ45), serial interfaces (RS-232), and USB ports, and is designed for panel mounting with a protection rating of IP65 on the front face. The device is compatible with Siemens WinCC flexible and SIMATIC WinCC visualization software.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, food and beverage, and process industries where a robust, panel-mounted PC with integrated display is required. Its fanless or low-maintenance design options make it suitable for environments with dust, vibration, and temperature variations. The unit serves as a central operator interface in machine control cabinets and process control rooms, often integrated with Siemens S7 PLC systems via PROFIBUS or Industrial Ethernet.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet RJ45, RS-232, USB |
| Operating System | Windows XP Embedded / Windows CE (variant dependent) |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly, possibly due to corrupted system files or storage media failure.
Check compact flash card or hard disk integrity. Reinstall or restore the operating system image using the Siemens recovery tool. - Event ID: 200
- Watchdog timeout — the application software stopped responding within the watchdog monitoring interval.
Restart the Panel PC. Check the WinCC or visualization application for software hangs. Verify CPU load and available memory. - Event ID: 300
- Communication error — loss of connection to the PLC or network device via Ethernet or PROFIBUS.
Check network cable connections and switch/hub status. Verify IP address configuration and PLC communication settings in WinCC. - Event ID: 400
- Temperature warning — internal temperature has exceeded the recommended operating threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean any dust from ventilation slots and verify fan operation if applicable. - Event ID: 500
- Storage media error — read/write error detected on the compact flash card or hard disk.
Back up project data immediately. Replace the compact flash card or hard disk with a compatible unit and restore the system image. - Event ID: 600
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power connector. Ensure the power supply unit is rated for the Panel PC load and check wiring for voltage drop. - Event ID: 700
- Touchscreen calibration error — the touch input is misaligned or unresponsive after a system restart.
Run the touchscreen calibration utility from the Windows control panel or Siemens service menu. If the issue persists, check the touch controller ribbon cable connection.
Frequently Asked Questions
What is the supply voltage for the 6AV7613-0AB10-0CE0?
The SIMATIC Panel PC 670 6AV7613-0AB10-0CE0 operates on a 24 V DC supply voltage, which is the standard for Siemens industrial panel devices.
Which visualization software is compatible with this Panel PC?
This unit is compatible with Siemens SIMATIC WinCC and WinCC flexible visualization software. It can also run third-party SCADA applications supported by the installed Windows operating system.
What communication interfaces are available on this unit?
The 6AV7613-0AB10-0CE0 provides Ethernet (RJ45), RS-232 serial, and USB interfaces for connectivity to PLCs, networks, and peripheral devices.
What is the front panel protection rating of this device?
The front panel of the SIMATIC Panel PC 670 is rated IP65, making it resistant to dust ingress and water jets, suitable for panel-mounted installations in industrial environments.
Can this Panel PC communicate directly with Siemens S7 PLCs?
Yes, the Panel PC 670 can communicate with Siemens S7-300 and S7-400 PLCs via Industrial Ethernet using the S7 communication protocol configured within WinCC or WinCC flexible.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator is illuminated. Check internal fuse if accessible.
Ensure the supply voltage is within the 24 V DC tolerance range. Replace any blown internal fuse. If the backlight has failed, the display inverter or backlight lamp may require replacement.
Touchscreen does not respond or responds inaccurately
Determine whether the issue is a calibration problem or a hardware fault by observing if touch inputs are registered but offset, or completely absent.
Run the touchscreen calibration utility from the Windows control panel. If the screen is completely unresponsive, check the ribbon cable connection between the touch panel and the controller board. Replace the touch overlay if damaged.
Panel PC fails to boot or continuously restarts
Observe the boot sequence on the display. Check if the system reaches the BIOS/POST screen. A failure before the OS load indicates a storage media or BIOS issue.
Replace or reformat the compact flash card and restore the Siemens factory system image. If the unit fails at POST, reseat RAM modules and check for hardware faults on the motherboard.
Loss of communication with PLC or network
Check the Ethernet cable and port LED indicators on the Panel PC and the connected switch. Verify IP address settings and subnet configuration in Windows network settings.
Replace the Ethernet cable if damaged. Reconfigure the IP address to match the network subnet. Check firewall settings and WinCC communication channel configuration for correct PLC addressing.
System clock resets to default date and time after power cycle
This indicates that the CMOS battery on the motherboard is depleted and is no longer maintaining the real-time clock when power is removed.
Replace the CMOS coin cell battery (typically CR2032) on the Panel PC motherboard. After replacement, set the correct date and time in the BIOS and Windows system settings.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page



