Siemens 6AV7613-0AA32-0CJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA32-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a high-performance computing platform with a robust, fanless or fan-cooled design suited for continuous operation on the factory floor.
The SIMATIC Panel PC 670 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen interface. It is equipped with an Intel Celeron or Pentium M processor, supports Windows XP Professional or Windows XP Embedded as the operating system, and provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial COM ports. The unit operates on a 24 V DC supply voltage and is built to meet industrial EMC and environmental standards, with a front panel protection rating of IP65.
The SIMATIC Panel PC 670 is widely used in automotive manufacturing, process industries, machine building, and packaging machinery where a full Windows-based PC environment is required at the operator station. Its rugged construction and industrial-grade components make it suitable for integration into control cabinets or machine panels where reliable, long-term visualization and data processing are essential. The unit supports SIMATIC WinCC, WinCC flexible, and other SCADA or HMI software packages.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Voltage Tolerance | 19.2 V DC to 28.8 V DC |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interfaces | 2x USB, 1x Ethernet RJ45 (10/100 Mbit/s), 2x COM (RS-232) |
| Operating System | Windows XP Professional / Windows XP Embedded |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cUL |
| Series | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if corrupted. - Event ID: 200
- 24 V DC supply voltage out of permissible range.
Measure supply voltage at the power connector. Ensure voltage is within 19.2 V DC to 28.8 V DC. Check power supply unit and wiring. - Event ID: 300
- Overtemperature condition detected inside the Panel PC.
Check ambient temperature and ensure it is within the 0 °C to +45 °C operating range. Clean air vents and verify cooling fan operation if fitted. - Event ID: 400
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen using the Windows control panel touchscreen calibration utility. If the issue persists, check the touchscreen controller connection or replace the touchscreen assembly. - Event ID: 500
- Ethernet communication failure or network interface not detected.
Check Ethernet cable and network switch connection. Verify network adapter settings in Windows Device Manager. Replace Ethernet cable or check RJ45 connector integrity. - Event ID: 600
- Hard disk or CompactFlash storage device not found or read error.
Reseat the storage device. Check for physical damage to the storage media. Replace the hard disk or CompactFlash card and restore the operating system image. - Event ID: 700
- USB device error or USB port not functioning.
Disconnect and reconnect the USB device. Try an alternate USB port. Check Windows Device Manager for driver conflicts and update or reinstall USB drivers as needed.
Frequently Asked Questions
What is the supply voltage for the 6AV7613-0AA32-0CJ0?
The unit operates on a 24 V DC supply voltage with a permissible range of 19.2 V DC to 28.8 V DC.
What operating system does the SIMATIC Panel PC 670 6AV7613-0AA32-0CJ0 support?
This Panel PC supports Windows XP Professional and Windows XP Embedded. It is compatible with SIMATIC WinCC and WinCC flexible HMI software.
What is the front panel protection rating of this unit?
The front panel of the 6AV7613-0AA32-0CJ0 carries an IP65 protection rating, making it resistant to dust and water jets. The rear of the unit is rated IP20.
What communication interfaces are available on this Panel PC?
The unit provides two USB ports, one Ethernet RJ45 port (10/100 Mbit/s), and two serial COM ports (RS-232).
Is the touchscreen on this Panel PC resistive or capacitive?
The 6AV7613-0AA32-0CJ0 uses a resistive touchscreen technology, which is operable with gloves and is well-suited for industrial environments.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify the voltage is within the 19.2 V to 28.8 V range. Inspect internal fuses and the backlight inverter board.
Restore supply voltage to within specification. Replace the backlight inverter or CCFL backlight lamp if the display remains dark but the PC is otherwise operational. Replace the internal power supply module if voltage is absent.
Panel PC fails to boot or gets stuck at POST screen
Attempt to boot from an external USB device to isolate whether the issue is with the internal storage. Check BIOS for detected storage devices and verify boot order settings.
Replace the internal hard disk or CompactFlash card and restore the operating system image from a Siemens recovery medium. Reseat RAM modules if POST fails before storage detection.
Touchscreen does not respond or registers incorrect touch positions
Verify that the touchscreen calibration has not been corrupted. Access the touchscreen calibration utility via the Windows control panel. Check the touchscreen controller cable connection internally.
Recalibrate the touchscreen using the Windows calibration tool. If calibration fails or touch remains unresponsive, inspect the internal ribbon cable connection to the touchscreen controller and replace the touchscreen assembly if damaged.
Ethernet communication is lost or the network adapter is not recognized
Check the Ethernet cable and connection to the network switch. Open Windows Device Manager and verify the network adapter is listed without errors. Check for IP address conflicts on the network.
Replace the Ethernet cable and verify switch port operation. Reinstall the network adapter driver from the Siemens recovery image. If the adapter is not detected in Device Manager, the onboard NIC may require board-level repair or replacement.
Unit overheats and shuts down unexpectedly
Check the ambient temperature around the Panel PC installation. Inspect air vents for dust blockage. If the unit has a cooling fan, verify it is spinning at normal speed.
Clean all air vents and heat sink fins with compressed air. Ensure the installation environment does not exceed 45 °C ambient temperature. Replace the cooling fan if it is not operating. Verify that the panel cutout provides adequate clearance for airflow as specified in the installation manual.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page