Siemens 6AV7613-0AA32-0CG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA32-0CG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface applications, combining a high-performance computing platform with an integrated flat-panel display in a rugged, panel-mount enclosure. This unit is part of Siemens' SIMATIC HMI product line, intended for use as an operator station in industrial automation environments.
The SIMATIC Panel PC 670 6AV7613-0AA32-0CG0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology. The unit is built around an x86-compatible processor platform and supports standard PC interfaces including USB, serial (RS-232), and Ethernet ports for connectivity to PLCs and SCADA systems. It is designed to run Windows-based operating systems, enabling compatibility with standard SCADA and visualization software such as Siemens WinCC. The front panel carries an IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine tool industries where a robust, panel-integrated PC solution is required. It is suitable for use as a central operator interface on production lines, packaging machinery, and process control stations. Its industrial-grade construction and compatibility with Siemens automation software make it a practical choice for integration into existing Siemens-based control architectures.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Display Colors | 65,536 colors |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Front Panel Protection Rating | IP65 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Mounting | Panel mount |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card for integrity. Verify BIOS settings and re-seat storage media. Replace storage device if faulty. - Event ID: 200
- Fan failure or thermal management warning. Internal cooling fan not operating within specification.
Inspect and clean the cooling fan. Replace the fan unit if it is not spinning or is running below rated speed. Ensure ambient temperature is within specification. - Event ID: 300
- Ethernet communication link failure. No network connection detected on the onboard Ethernet interface.
Check Ethernet cable and switch/hub connection. Verify IP address configuration in the operating system. Replace Ethernet cable or check network adapter settings. - Event ID: 400
- Touchscreen calibration error. Touch input coordinates are misaligned or unresponsive.
Run the touchscreen calibration utility from the Windows control panel or Siemens HMI configuration tool. If unresponsive, check the touch controller ribbon cable connection internally. - Event ID: 500
- Power supply undervoltage detected. Supply voltage has dropped below the minimum operating threshold.
Measure the 24 V DC supply at the power input connector. Ensure the power supply unit can deliver sufficient current. Replace or adjust the external power supply as needed. - Event ID: 600
- Hard disk or storage media error. Read/write failure detected on the internal storage device.
Run a disk check utility (e.g., chkdsk) from the operating system. Back up data immediately. Replace the hard disk or CompactFlash card if errors persist. - Event ID: 700
- WinCC Runtime communication fault. Loss of communication between WinCC and the connected PLC or controller.
Verify PLC connection settings and communication driver configuration in WinCC. Check Ethernet or serial cable connections. Restart the WinCC Runtime application and confirm PLC is in RUN mode.
Frequently Asked Questions
What is the supply voltage for the 6AV7613-0AA32-0CG0?
The SIMATIC Panel PC 670 6AV7613-0AA32-0CG0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What operating system does this Panel PC support?
The SIMATIC Panel PC 670 is designed to run Windows-based operating systems, typically Windows XP Professional or Windows 2000, enabling compatibility with Siemens WinCC and other SCADA visualization software.
What is the display size and resolution of this unit?
The 6AV7613-0AA32-0CG0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
What is the front panel protection rating?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, providing full dust protection and resistance to water jets from any direction.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens WinCC visualization software and is commonly used as an operator station in Siemens-based automation systems.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power input connector. Verify that the internal backlight inverter is functioning and that the display cable is securely connected.
Ensure the 24 V DC supply is within tolerance. If the backlight is faulty, replace the backlight inverter or the display assembly. Re-seat all internal display connectors.
Touchscreen does not respond or registers incorrect touch positions
Attempt to recalibrate the touchscreen using the Windows calibration utility. Check for physical damage to the touch overlay or contamination on the screen surface.
Run the touchscreen calibration tool. Clean the screen surface. If calibration fails repeatedly, inspect the internal touch controller ribbon cable connection and replace the touch overlay if damaged.
Unit fails to boot or gets stuck at POST screen
Check the internal storage device (hard disk or CompactFlash card) for errors. Verify BIOS settings are correct and that the boot device is properly detected.
Run a disk integrity check. Re-seat or replace the storage media. If the BIOS battery (CMOS battery) is depleted, replace it to restore BIOS settings.
No Ethernet communication with PLC or network
Verify the Ethernet cable connection and check the link/activity LEDs on the RJ45 port. Confirm the IP address configuration in the operating system matches the network settings.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings. Update or reinstall the Ethernet adapter driver if the interface is not recognized by the operating system.
Panel PC overheating or shutting down unexpectedly
Check the ambient temperature around the unit and verify that ventilation slots are not blocked. Inspect the internal cooling fan for operation.
Ensure the installation environment is within the 0 °C to +45 °C operating temperature range. Clean dust from ventilation openings and replace the internal cooling fan if it is not functioning correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page