
Siemens 6AV7613-0AA32-0AH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA32-0AH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-resolution display with a robust industrial PC platform, offering a compact all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7613-0AA32-0AH0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors, providing clear visualization of process data. The unit is based on an x86-compatible processor architecture and runs Microsoft Windows operating systems, supporting standard industrial software including Siemens WinCC and other SCADA packages. It provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-485), enabling integration with a wide range of automation systems and field devices. The panel is designed for front-panel mounting with an IP65 protection rating on the front face, ensuring resistance to dust and water ingress in industrial environments.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, automotive production, and machine building applications where a robust, integrated HMI and PC platform is required. Its compatibility with standard Windows-based software and Siemens automation systems makes it suitable for integration into existing SIMATIC environments. The unit is commonly deployed in control cabinets and operator stations on production lines, packaging machinery, and plant-level visualization systems.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 64,000 colors |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front panel) |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232, RS-485 |
| Mounting | Panel mounting (front mount) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Microsoft Windows |
Common Error Codes & System Events
- Event ID: 100
- System startup failure or BIOS POST error detected during boot sequence
Check hardware connections, reseat memory modules, and verify that all internal components are properly seated. If the issue persists, replace the defective hardware component. - Event ID: 200
- Operating system boot failure or corrupted system partition
Boot from recovery media and perform a system restore or reinstall the operating system. Verify hard disk or CompactFlash card integrity. - Event ID: 300
- Ethernet communication link failure or network interface not detected
Check Ethernet cable connections and network switch configuration. Verify network adapter settings in Device Manager and update or reinstall network drivers if necessary. - Event ID: 400
- Touchscreen or input device not responding or calibration lost
Recalibrate the touchscreen via the Windows control panel or Siemens HMI configuration tool. If calibration fails, check the touchscreen controller connection internally. - Event ID: 500
- Internal temperature exceeded operating threshold
Check ambient temperature around the panel. Ensure ventilation slots are not blocked. Verify that the internal fan (if fitted) is operating correctly and clean any dust from ventilation areas. - Event ID: 600
- Power supply voltage out of tolerance or undervoltage detected
Measure the 24 V DC supply voltage at the panel connector. Ensure the power supply unit provides stable voltage within the specified tolerance range of 24 V DC (-15%/+20%). - Event ID: 700
- WinCC Runtime communication error with PLC or controller
Verify the PLC connection configuration in WinCC, check Ethernet or serial cable integrity, and confirm that the PLC is powered and running. Check firewall settings on the Panel PC.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7613-0AA32-0AH0?
The SIMATIC Panel PC 670 (6AV7613-0AA32-0AH0) operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.
What display size and resolution does this Panel PC have?
This unit features a 12.1-inch TFT LCD display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors, suitable for detailed process visualization.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other Windows-based SCADA and HMI software packages, as it operates on a standard Microsoft Windows operating system.
What is the front panel protection rating of this unit?
The front panel of the 6AV7613-0AA32-0AH0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial environments.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-485), enabling connectivity to PLCs, field devices, and corporate networks.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector with a multimeter. Check for blown internal fuses and verify that the power connector is fully seated.
Replace any blown fuses with the correct rating. If the supply voltage is within specification and the unit still does not power on, the internal power supply board may require replacement or repair.
Display is blank or backlight does not illuminate after boot
Check if the operating system is booting correctly by connecting an external monitor if possible. Verify the backlight inverter connection and check for any BIOS display output settings.
If the OS boots correctly but the display remains blank, the backlight inverter or the TFT panel itself may be faulty and should be replaced. Adjust display settings in the BIOS or Windows if the external monitor shows output.
Touchscreen input is inaccurate or not responding
Attempt to recalibrate the touchscreen using the Windows touchscreen calibration utility. Check Device Manager for touchscreen controller errors or missing drivers.
Recalibrate the touchscreen. If the controller is not detected, reinstall the touchscreen drivers. If the touchscreen remains unresponsive after driver reinstallation, the touchscreen overlay or controller board may need replacement.
Ethernet communication to PLC is intermittent or lost
Check the Ethernet cable for damage and verify the connection at both the Panel PC and the network switch. Use the Windows network diagnostics tool to check the adapter status and IP configuration.
Replace the Ethernet cable if damaged. Verify IP address settings and subnet configuration. If the network adapter is not detected, update or reinstall the network driver. Check for IP address conflicts on the network.
Panel PC runs slowly or WinCC Runtime performance is degraded
Check CPU and memory utilization in Windows Task Manager. Verify available disk space on the system drive. Check for background processes consuming excessive resources.
Close unnecessary background applications and disable non-essential startup programs. If the system drive (hard disk or CompactFlash) is nearly full, archive or delete old data. Consider defragmenting the hard disk or replacing an aging storage device.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page



