Siemens 6AV7613-0AA32-0AG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA32-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an industrial-grade processor platform running Microsoft Windows, with interfaces including USB ports, serial COM ports, and Ethernet for network connectivity. The unit is designed for front-panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress in industrial settings.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine visualization applications across industries such as automotive, food and beverage, chemical processing, and packaging. Its compatibility with Siemens SIMATIC WinCC and other SCADA software makes it a suitable platform for supervisory control and data acquisition tasks. The integrated PC architecture allows it to run standard industrial software alongside HMI applications simultaneously.
Technical Specifications
| Series | SIMATIC Panel PC 670 |
|---|---|
| Display Size | 12 inch |
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM ports) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Front panel mounting |
| Certifications | CE, UL |
| Operating System | Microsoft Windows XP Embedded |
Common Error Codes & System Events
- Event ID: 1000
- Application error – a software application has encountered an unexpected fault and terminated.
Check Windows Event Viewer for details. Reinstall or update the affected application. Ensure WinCC or HMI runtime software is correctly licensed and configured. - Event ID: 6008
- Unexpected system shutdown – the Panel PC was not shut down cleanly on the previous session.
Check power supply stability at the 24 V DC input. Verify UPS or power conditioning is in place. Inspect for loose connectors at the power input terminal. - BIOS POST Error
- Hardware fault detected during Power-On Self-Test, preventing normal boot.
Check that all internal memory modules and expansion cards are properly seated. Clear CMOS if settings are corrupted. Contact service if hardware failure is confirmed. - WinCC Runtime Error
- SIMATIC WinCC runtime has failed to start or has crashed during operation.
Verify WinCC license is valid and installed correctly. Check available disk space and RAM. Reinstall WinCC runtime if the issue persists. - Network Connection Lost
- Ethernet communication to the PLC or SCADA server has been interrupted.
Check Ethernet cable and RJ45 connector integrity. Verify IP address configuration in Windows network settings. Test connectivity with ping command to the target PLC or server. - Touchscreen Not Responding
- The resistive touch screen is not registering input or is misaligned.
Recalibrate the touch screen using the Windows control panel touch calibration utility. Clean the screen surface. If calibration fails, inspect the touch controller connection internally or replace the touch overlay. - Hard Disk Failure Warning
- The internal hard disk drive or CompactFlash storage device is reporting errors or has failed.
Back up all project data immediately. Run a disk check utility (chkdsk) to assess disk health. Replace the internal HDD or CompactFlash card and restore the system image.
Frequently Asked Questions
What is the supply voltage for the 6AV7613-0AA32-0AG0?
The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.
What operating system does this Panel PC run?
The 6AV7613-0AA32-0AG0 runs Microsoft Windows XP Embedded, which is pre-installed and optimized for industrial HMI operation.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC visualization software, making it suitable for SCADA and HMI applications within the Siemens automation ecosystem.
What is the front panel protection rating of this unit?
The front panel of the 6AV7613-0AA32-0AG0 carries an IP65 protection rating, providing full dust protection and resistance to water jets.
What display size and resolution does this Panel PC have?
The unit features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA), with resistive touch screen input.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector with a multimeter. Check for blown internal fuses. Verify the power supply unit can deliver sufficient current.
Replace any blown internal fuses with the correct rated fuse. If the power supply voltage is within specification and the unit still does not start, the internal power supply board may need replacement.
Display is blank or shows no image after boot
Check whether the PC is booting by listening for hard disk activity or connecting an external monitor if supported. Verify the backlight inverter is functioning by looking for a faint image with a flashlight.
Replace the CCFL backlight or inverter board if the backlight has failed. If no image is present at all, inspect the display cable connections internally or replace the TFT display panel.
Touch screen input is inaccurate or not responding
Attempt to recalibrate the touch screen through the Windows Control Panel. Check if the touch overlay surface is dirty or damaged.
Clean the screen with a soft, dry cloth and recalibrate using the Windows touch calibration tool. If the touch screen remains unresponsive, inspect the internal touch controller ribbon cable connection or replace the resistive touch overlay.
System freezes or reboots unexpectedly during operation
Check Windows Event Viewer for critical errors or blue screen dump files. Monitor the 24 V DC supply for voltage drops under load. Check CPU temperature if accessible via BIOS.
Stabilize the power supply and ensure adequate current capacity. Clean internal cooling vents and fans to prevent thermal shutdown. If software-related, reinstall the operating system or HMI runtime application.
Ethernet communication to PLC is lost intermittently
Inspect the RJ45 connector and Ethernet cable for physical damage or loose fit. Check Windows network adapter settings for correct IP configuration and duplex settings.
Replace the Ethernet cable and ensure the RJ45 connector is firmly seated. Set the network adapter to a fixed speed and duplex mode matching the connected switch or PLC port. Update network adapter drivers if available.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page