
Siemens 6AV7613-0AA32-0AJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA32-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-resolution display with a robust industrial PC platform, providing a versatile computing and visualization solution in a single integrated device.
The SIMATIC Panel PC 670 6AV7613-0AA32-0AJ0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 65,536 colors. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, enabling compatibility with standard SCADA and HMI software packages including SIMATIC WinCC. The unit provides communication interfaces including Ethernet (RJ45) and USB ports, and supports expansion via PCI slots. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine tool industries where a full PC-based HMI platform is required. Its ability to run standard Windows-based software makes it suitable for complex visualization, data logging, and process control applications. Industries such as automotive, food and beverage, chemical processing, and packaging commonly utilize this panel PC for supervisory control and operator interface stations.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 65,536 colors |
| Display Type | TFT LCD |
| IP Protection Rating (Front) | IP65 |
| Operating Voltage | 24 V DC |
| Communication Interface | Ethernet (RJ45), USB |
| Operating System | Microsoft Windows |
| Processor | Intel Celeron |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the integrity of the Windows installation. Verify the hard disk or CompactFlash card is properly seated and functioning. Reinstall the OS if necessary. - Event ID: 1000
- Application fault — a running HMI or SCADA application has crashed unexpectedly.
Review the Windows Event Viewer for detailed error logs. Reinstall or update the affected application. Check for memory or hardware conflicts. - BIOS POST Error
- Hardware self-test failure detected during power-on self-test (POST).
Check all internal connections, RAM modules, and expansion cards. Reseat components and reboot. Replace faulty hardware if the error persists. - Watchdog Timeout
- The system watchdog timer has expired, indicating the OS or application has become unresponsive.
Investigate CPU load and running processes. Optimize or reduce application load. Check for OS or driver issues causing system hangs. - Fan Failure Warning
- Internal cooling fan has stopped or is running below the required speed threshold.
Inspect and clean the fan. Replace the fan unit if it is not operating correctly to prevent thermal shutdown. - Temperature Warning
- Internal temperature has exceeded the defined operating threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean air filters and verify fan operation. Reduce heat load if possible. - Hard Disk Error
- Read/write error detected on the internal hard disk or storage medium.
Run a disk diagnostic utility. Back up data immediately. Replace the hard disk or CompactFlash card if errors persist. - Network Communication Error
- Ethernet communication to the PLC or network has been lost or cannot be established.
Check Ethernet cable connections and network switch status. Verify IP address configuration. Inspect the network interface card and replace if faulty.
Frequently Asked Questions
What display size and resolution does the 6AV7613-0AA32-0AJ0 have?
This Panel PC features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 65,536 colors.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 6AV7613-0AA32-0AJ0 carries an IP65 protection rating, providing full dust protection and resistance to water jets.
What operating system does this Panel PC support?
The unit supports Microsoft Windows operating systems, enabling compatibility with standard industrial HMI and SCADA software such as Siemens SIMATIC WinCC.
What communication interfaces are available on this Panel PC?
The 6AV7613-0AA32-0AJ0 provides Ethernet (RJ45) and USB interfaces as standard, allowing connectivity to PLCs, networks, and peripheral devices.
Can this Panel PC be used with SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens SIMATIC WinCC and other Windows-based HMI and SCADA software packages.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power input connector. Verify the power LED status. Measure voltage at the internal power supply output rails.
Ensure the 24 V DC supply is within specification. Replace the internal power supply if output voltages are absent. If the display backlight has failed, replace the backlight inverter or display assembly.
Panel PC fails to boot into Windows
Listen for POST beep codes and observe any BIOS error messages on screen. Check whether the hard disk or CompactFlash storage is detected in the BIOS.
Reseat the storage medium and all internal connectors. If the storage device is not detected or reports errors, replace it and reinstall the operating system.
Touchscreen does not respond or is inaccurate
Check the touchscreen controller connection internally. Verify that the touchscreen driver is correctly installed in Windows Device Manager.
Recalibrate the touchscreen using the Windows calibration utility. If calibration fails, reinstall the touchscreen driver. Replace the touchscreen overlay if physical damage is present.
Ethernet communication to PLC is lost
Check the Ethernet cable and network switch port. Verify the IP address and subnet mask configuration in Windows network settings. Ping the PLC from the Panel PC.
Replace the Ethernet cable if damaged. Correct any IP configuration errors. If the network interface card is faulty, replace it or use a USB-to-Ethernet adapter as a temporary measure.
System overheating or unexpected shutdown
Check the internal temperature via BIOS or system monitoring software. Inspect the cooling fan for operation and cleanliness. Verify ambient temperature around the panel.
Clean dust from the fan and ventilation openings. Ensure the installation environment does not exceed 45 °C ambient temperature. Replace the cooling fan if it is not operating correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page



