Siemens 6AV7612-0AF22-0BF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AF22-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a fully functional PC platform, enabling both operator control and data processing within a single compact device.
The SIMATIC Panel PC 670 (6AV7612-0AF22-0BF0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touch-sensitive screen for intuitive operator interaction. It is powered by an Intel Celeron processor and runs Microsoft Windows XP or Windows 2000, supporting standard PC software environments. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is built with a fanless or low-noise design suited for continuous industrial operation. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a robust, integrated PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its compatibility with Siemens SIMATIC WinCC and other SCADA software makes it a practical choice for visualization and supervisory control tasks.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 |
| Operating System | Windows XP / Windows 2000 |
| Processor | Intel Celeron |
| Mounting | Panel mounting |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 1000
- Application error – a software application has encountered an unexpected fault and terminated.
Check Windows Event Viewer for details. Reinstall or update the affected application. Verify software compatibility with the installed OS version. - Event ID: 6008
- Unexpected shutdown – the system was shut down unexpectedly, indicating a possible power loss or system crash.
Check the 24 V DC power supply for stability and correct voltage. Inspect power connectors and cabling. Review Event Viewer logs for preceding errors. - Event ID: 7026
- Driver load failure – a boot-start or system-start driver failed to load during startup.
Boot into safe mode and check Device Manager for driver conflicts. Reinstall or update the relevant hardware driver. - BIOS POST Error
- Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
Reseat RAM modules and check hard disk or CompactFlash connections. Replace faulty storage media if the device is not detected. - Watchdog Timeout
- The system watchdog timer has expired, indicating the operating system or application has stopped responding.
Check for software hangs or infinite loops in the running application. Verify adequate CPU and memory resources. Update or reinstall the HMI application. - Temperature Warning
- Internal temperature has exceeded the defined threshold, risking thermal shutdown.
Check ambient temperature against specifications. Ensure ventilation slots are unobstructed. Verify the cooling fan (if fitted) is operational and clean filters if present. - Hard Disk Failure
- The internal hard disk drive or CompactFlash storage device has failed or is not accessible.
Replace the internal storage device with a compatible unit. Restore the operating system and application software from a backup image.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AF22-0BF0?
The SIMATIC Panel PC 670 (6AV7612-0AF22-0BF0) operates on a 24 V DC power supply.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7612-0AF22-0BF0 meets IP65 protection, providing full dust-tight protection and resistance to water jets.
Which HMI software is compatible with this Panel PC?
The unit is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other standard PC-based SCADA and HMI software packages that run on Windows XP or Windows 2000.
What communication interfaces are available on this unit?
The 6AV7612-0AF22-0BF0 provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces for connectivity to PLCs, networks, and peripherals.
Can the storage medium be replaced in the field?
Yes, the internal storage device (hard disk or CompactFlash) can be replaced in the field. After replacement, the operating system and application software must be restored from a backup image.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power supply connector. Verify the power LED status. Measure voltage at the internal power supply output.
Ensure the 24 V DC supply is within tolerance. Replace the internal power supply board if no output voltage is present. If voltage is correct, the display backlight inverter or TFT panel may need replacement.
Touchscreen does not respond or is inaccurate
Check if the touch controller is recognized in Windows Device Manager. Attempt to recalibrate the touchscreen using the Windows calibration utility.
Recalibrate the touchscreen via the control panel. If unresponsive, check the internal touch controller ribbon cable connection. Replace the touchscreen overlay if calibration fails repeatedly.
System fails to boot or hangs at startup
Observe the boot sequence for BIOS POST errors. Check if the hard disk or CompactFlash card is detected in BIOS. Connect an external keyboard and monitor if available.
Reseat or replace the internal storage device. Restore the OS image from a backup. If the BIOS is not loading, the motherboard or CMOS battery may require inspection or replacement.
Ethernet communication not working
Check the Ethernet cable and switch port. Verify IP address configuration in Windows Network Settings. Check Device Manager for Ethernet adapter errors.
Replace the Ethernet cable and verify network switch operation. Reinstall the Ethernet adapter driver if shown as faulty in Device Manager. If the adapter is not detected, the onboard NIC may be defective and require board-level repair.
Unit shuts down unexpectedly during operation
Check the 24 V DC supply voltage under load for drops or instability. Review Windows Event Viewer for critical errors prior to shutdown. Monitor internal temperature via BIOS or system utilities.
Stabilize the power supply and check all power connectors for corrosion or loose contacts. If thermal shutdown is occurring, improve panel ventilation or reduce ambient temperature. Replace the power supply unit if voltage instability is confirmed.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page