Siemens 6AV7612-0AF22-0BG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AF22-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 6AV7612-0AF22-0BG0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 256,000 colors, providing clear visualization of process data. The unit is equipped with a touch screen interface and runs on a Windows-based operating system, supporting SIMATIC WinCC and other HMI software packages. It includes standard industrial communication interfaces such as Ethernet and serial ports, and is built to withstand industrial environments with an IP65-rated front panel for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine automation where a robust, integrated PC-based HMI solution is required. Its panel-mount design makes it suitable for integration into control cabinets and operator panels on production lines, packaging machinery, and process control systems. The combination of a high-performance processor, industrial-grade construction, and compatibility with Siemens SIMATIC software makes it a reliable platform for complex visualization and data acquisition tasks.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 256,000 |
| Display Type | TFT LCD |
| Touch Technology | Resistive touch screen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, RS-422/485 |
| Mounting | Panel mount |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup error or boot failure detected during POST.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and re-seat storage media. Replace storage media if faulty. - Event ID: 101
- Hardware watchdog timeout — the system did not respond within the watchdog interval.
Check CPU load and running processes. Reduce background tasks or increase watchdog timeout in BIOS settings. Inspect for hardware faults. - Event ID: 200
- Fan failure or thermal warning — cooling fan not operating at expected speed.
Clean or replace the internal cooling fan. Ensure ambient temperature is within specification. Check for blocked ventilation openings. - Event ID: 201
- Overtemperature condition detected — internal temperature exceeds threshold.
Verify ambient temperature is within 0–50 °C. Clean air filters and ventilation slots. Inspect fan operation and replace if necessary. - Event ID: 300
- Battery low warning — CMOS/RTC backup battery voltage is low.
Replace the internal CMOS backup battery (CR2032 or equivalent). After replacement, re-enter BIOS date/time and settings. - Event ID: 400
- Ethernet communication fault — network interface not detected or link failure.
Check Ethernet cable and switch/hub connection. Verify network configuration in the operating system. Replace Ethernet cable or check NIC hardware. - Event ID: 500
- Touch screen calibration error — touch input not responding correctly to screen coordinates.
Perform touch screen recalibration using the Siemens calibration utility in the control panel. Clean the touch surface and check for physical damage. - Event ID: 600
- Storage media error — read/write error on hard disk or CompactFlash card.
Run disk diagnostics. Back up data immediately and replace the storage media. Restore the operating system and HMI application from backup.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 6AV7612-0AF22-0BG0 run?
This Panel PC is designed to run Windows XP Professional or Windows XP Embedded, which are compatible with SIMATIC WinCC and other Siemens HMI software packages.
What is the display size and resolution of this unit?
The 6AV7612-0AF22-0BG0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 256,000 colors.
What is the supply voltage for this Panel PC?
The unit operates on a 24 V DC supply voltage, which is standard for industrial panel PCs in the SIMATIC family.
Is the front panel of this unit protected against dust and water?
Yes, the front panel carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), RS-232, and RS-422/485 serial interfaces, enabling connectivity to PLCs, SCADA systems, and other industrial devices.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the power LED status. Measure voltage at the internal power supply output.
Ensure the 24 V DC supply is within tolerance. Replace the internal power supply if voltage is absent at the output. Check and replace the backlight inverter or display if supply is confirmed good.
Touch screen does not respond or responds inaccurately
Check if the touch controller driver is loaded correctly in the operating system. Inspect the touch surface for contamination or physical damage.
Recalibrate the touch screen using the Siemens calibration utility. Clean the touch surface with a soft cloth. If the issue persists, replace the touch screen overlay or the touch controller board.
Unit fails to boot or continuously restarts
Check the CompactFlash card or hard disk for errors using disk diagnostics tools. Inspect BIOS settings for correct boot device selection.
Replace the storage media and restore the operating system and HMI application from a backup image. Re-enter BIOS settings after replacement.
Ethernet communication not established
Verify the Ethernet cable connection and check the link LED on the RJ45 port. Confirm IP address configuration in the operating system network settings.
Replace the Ethernet cable and verify switch/hub port operation. Reconfigure the IP address settings if necessary. If the NIC is faulty, the unit may require board-level repair.
CMOS settings lost after power off
The CMOS backup battery is likely discharged. This is indicated by incorrect date/time after each power cycle and possible BIOS error messages on boot.
Replace the internal CMOS backup battery (typically CR2032). After replacement, re-enter the correct date, time, and BIOS configuration settings.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page