Siemens 6AV7612-0AF22-0BE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AF22-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface applications, combining a built-in display with a full PC architecture running Windows-based operating systems. This unit is part of Siemens' SIMATIC HMI portfolio and is intended for use as a high-performance operator station in industrial environments.
The 6AV7612-0AF22-0BE0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen functionality. It is built around an x86-compatible processor platform and supports communication via standard industrial interfaces including Ethernet (RJ45), serial ports (RS-232), and USB ports. The unit is designed for panel mounting and offers a fanless or low-maintenance design suited to continuous industrial operation, with an IP65 protection rating on the front panel to resist dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full Windows-based PC environment is required at the operator level. It is suitable for industries such as automotive, food and beverage, pharmaceuticals, and general factory automation. Its compatibility with Siemens WinCC and other SCADA software makes it a practical choice for visualization and data acquisition tasks at the machine or line level.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 65,536 colors (16-bit) |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP/Protection Rating | IP65 (front panel) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Watchdog timeout triggered — application software stopped responding within the defined monitoring interval.
Restart the application. Check for software deadlocks or resource conflicts. Update or reinstall the HMI runtime software if the issue persists. - Event ID: 300
- Ethernet communication loss — connection to PLC or network device interrupted.
Check Ethernet cable and connector integrity. Verify IP address configuration and network switch status. Confirm PLC communication settings match Panel PC configuration. - Event ID: 400
- Touchscreen calibration error — touch input not aligned with display output.
Run the touchscreen calibration utility from the Windows Control Panel or SIMATIC settings. Clean the touch surface and recalibrate. Replace touchscreen assembly if calibration fails repeatedly. - Event ID: 500
- Internal temperature warning — processor or system temperature exceeded normal operating threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean any air vents or filters. Verify that the panel is not installed in an enclosure exceeding rated thermal limits. - Event ID: 600
- Power supply undervoltage detected — supply voltage dropped below the 24 V DC operating threshold.
Measure the DC supply voltage at the panel connector. Ensure the power supply unit is rated for the load. Check wiring for excessive voltage drop and replace the power supply if necessary. - Event ID: 700
- Hard disk or storage media error — read/write failure detected on the primary storage device.
Run a disk check utility (chkdsk) to identify file system errors. Back up data immediately. Replace the hard disk or CompactFlash card if hardware errors are confirmed.
Frequently Asked Questions
What operating system does the 6AV7612-0AF22-0BE0 support?
The SIMATIC Panel PC 670 6AV7612-0AF22-0BE0 is designed to run Windows XP Professional or Windows XP Embedded, which were the standard operating systems for this panel PC generation. Compatibility with newer Windows versions depends on available drivers and hardware support.
What is the supply voltage for this Panel PC?
The unit operates on 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 series devices.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and WinCC flexible SCADA and HMI software, making it suitable for visualization and process monitoring applications.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AF22-0BE0 carries an IP65 protection rating, providing protection against dust ingress and low-pressure water jets.
Can the storage media be replaced or upgraded?
Yes, the SIMATIC Panel PC 670 typically uses a removable hard disk or CompactFlash card for storage, which can be replaced or upgraded. Siemens recommends using approved storage media to ensure compatibility and reliability.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the panel connector using a multimeter. Verify that the power LED indicator is active. Inspect internal fuse and backlight inverter board.
Restore correct 24 V DC supply if voltage is out of range. Replace the backlight lamp or inverter board if the display backlight has failed. If the unit does not boot, check the storage media and reseat or replace it.
Touchscreen does not respond or responds inaccurately
Determine whether the issue is a calibration problem or a hardware failure by observing if touch inputs are offset from the cursor position or completely absent.
Run the touchscreen calibration tool from the Windows Control Panel. If calibration does not resolve the issue, inspect the touchscreen ribbon cable connection. Replace the touchscreen overlay if the hardware is physically damaged.
Panel PC fails to boot into Windows
Observe the boot sequence on screen. Check for BIOS error messages, missing operating system errors, or disk read errors during POST.
Reseat the hard disk or CompactFlash card. Run a disk integrity check if the system can boot into recovery mode. Restore the operating system image from a Siemens-approved backup or replace the storage media.
Ethernet communication with PLC is intermittent or lost
Check the Ethernet cable and RJ45 connector for physical damage. Verify the IP address and subnet mask settings in Windows Network Connections. Use a network ping test to confirm connectivity.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network topology. Update the Ethernet driver if communication errors persist after physical checks.
System overheats and shuts down unexpectedly
Monitor the system temperature using BIOS or a hardware monitoring utility. Check the ambient temperature of the installation environment and inspect ventilation around the panel cutout.
Ensure the installation environment does not exceed 50 °C ambient temperature. Verify that the panel enclosure provides adequate thermal dissipation. Clean any dust from ventilation areas and confirm that thermal pads or heat sinks are properly seated internally.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page