Siemens 6AV7612-0AE30-0AF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE30-0AF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface and visualization tasks in automation environments. This unit combines a high-performance computing platform with an integrated flat-panel display in a rugged, industrial-grade enclosure.
The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels and touch screen capability, enabling intuitive operator interaction. It is equipped with an Intel Celeron or Pentium processor, supports Windows XP Professional or Windows 2000 as the operating system, and provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces. The unit is designed for front-panel mounting with an IP65-rated front face, protecting against dust and water ingress in industrial environments. Expansion slots allow for additional interface cards, and the system supports standard industrial memory configurations.
The SIMATIC Panel PC 670 is widely deployed in manufacturing automation, process control, and machine visualization applications across industries such as automotive, food and beverage, chemical processing, and packaging. Its compatibility with Siemens SIMATIC WinCC and other SCADA software makes it suitable for complex supervisory control and data acquisition tasks. The robust construction and industrial-grade components ensure reliable long-term operation in environments with vibration, temperature variation, and electrical noise.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive Touch Screen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 65 W |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet RJ45, USB, RS-232 |
| Mounting | Panel mounting (front flush) |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat memory modules. Replace storage media if corrupted. - Event ID: 200
- Watchdog timeout triggered, indicating the application or OS became unresponsive.
Restart the Panel PC. Investigate application software for infinite loops or resource conflicts. Update or reinstall the runtime software. - Event ID: 300
- Fan failure or thermal warning detected; internal temperature exceeding safe operating limits.
Check and clean cooling fan and ventilation slots. Verify ambient temperature is within specification. Replace fan unit if faulty. - Event ID: 400
- Ethernet communication link failure or network interface not detected.
Check Ethernet cable connection and switch/hub status. Verify network adapter settings in the operating system. Replace cable or network adapter if defective. - Event ID: 500
- Touch screen calibration error or touch input not responding correctly.
Recalibrate the touch screen via the operating system control panel or SIMATIC touch calibration utility. Clean the screen surface and check touch controller connections. - Event ID: 600
- Power supply undervoltage detected; supply voltage outside the permissible 24 V DC range.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance. Replace power supply if out of range. - Event ID: 700
- Hard disk or CompactFlash storage device read/write error or device not found.
Check storage device seating and connections. Run disk diagnostics. Replace the hard disk or CompactFlash card if errors persist.
Frequently Asked Questions
What operating systems are supported by the SIMATIC Panel PC 670 (6AV7612-0AE30-0AF0)?
The SIMATIC Panel PC 670 supports Windows XP Professional and Windows 2000 Professional as factory-installed operating systems. The specific OS version depends on the order configuration.
What is the supply voltage for the 6AV7612-0AE30-0AF0?
This Panel PC operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 series units.
Is the 6AV7612-0AE30-0AF0 compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC and WinCC flexible visualization software, making it suitable for SCADA and HMI applications.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AE30-0AF0 carries an IP65 protection rating, providing full dust protection and protection against water jets.
Can the SIMATIC Panel PC 670 be expanded with additional interface cards?
Yes, the Panel PC 670 provides expansion slots that allow installation of additional interface cards such as PROFIBUS or additional serial communication cards, depending on available slots in the specific configuration.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify the internal fuse and inspect the power supply board for visible damage.
Restore the supply voltage to within the 24 V DC specification. Replace the internal fuse if blown. If the power supply board is faulty, replace the power supply module or return the unit for repair.
Touch screen does not respond or registers incorrect touch positions
Determine whether the issue is a calibration problem or a hardware failure by attempting recalibration via the OS control panel. Inspect the touch controller ribbon cable connection.
Recalibrate the touch screen using the SIMATIC calibration utility or Windows control panel. If calibration fails, reseat the touch controller ribbon cable. Replace the touch screen overlay if the controller is confirmed defective.
Panel PC fails to boot or continuously restarts
Connect an external monitor via the available video output to check for BIOS POST messages. Check the hard disk or CompactFlash card for errors using diagnostic tools.
Reseat memory modules and storage devices. Restore or reinstall the operating system image if the storage media is corrupted. Replace the storage device if hardware failure is confirmed.
Ethernet communication not established
Check the Ethernet cable and verify link LEDs on the RJ45 port. Confirm network adapter settings and IP configuration within the operating system.
Replace the Ethernet cable if damaged. Reconfigure the network adapter settings in the OS. If the onboard Ethernet port is defective, install a compatible expansion network card.
Unit overheating or fan running at maximum speed continuously
Measure the ambient temperature around the unit and check that ventilation clearances are maintained. Inspect the cooling fan for blockage or mechanical failure.
Ensure the installation environment is within the 0 to 45 degrees C operating range. Clean dust from ventilation slots and fan blades. Replace the cooling fan if it is not operating correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page