• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE30-0AG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE30-0AG0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE30-0AG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE30-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens as part of its industrial computing platform. This unit is a high-performance industrial panel PC designed for demanding visualization and control tasks in automation environments. It integrates a flat-panel display with a built-in computing unit, offering a compact and robust solution for machine-level HMI and SCADA applications.

    The SIMATIC Panel PC 670 6AV7612-0AE30-0AG0 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation for intuitive operator interaction. The unit is built around an industrial-grade processor platform and supports Windows-based operating systems, enabling compatibility with standard SCADA and visualization software including WinCC. It provides multiple communication interfaces such as Ethernet (RJ45), USB ports, and serial interfaces, and is designed for panel mounting with an IP65-rated front face for protection against dust and water ingress.

    This Panel PC is widely used in the automotive, food and beverage, chemical, and machine building industries where robust, long-lifecycle industrial computing is required at the machine or line level. Its fanless or low-maintenance design options and industrial-grade components make it suitable for continuous operation in environments with vibration, temperature variation, and electromagnetic interference. The unit is commonly deployed as an operator station in process visualization, production monitoring, and machine control applications.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 px (XGA)
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Mounting Panel mounting
    Communication Interfaces Ethernet (RJ45), USB, RS-232
    Operating System Windows XP / Windows 2000 (industrial)
    Series SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST sequence.
    Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration in BIOS settings.
    Event ID: 200
    Watchdog timeout triggered, indicating the application software has stopped responding.
    Restart the Panel PC. Check the WinCC or SCADA application for software hangs or memory leaks. Update or reinstall the application if the issue persists.
    Event ID: 300
    Fan failure or thermal warning detected; internal temperature has exceeded threshold.
    Check and clean ventilation openings. Verify fan operation. Ensure ambient temperature is within the specified operating range of 0 °C to +45 °C.
    Event ID: 400
    Ethernet communication link failure; no network connection detected.
    Check Ethernet cable and switch/hub connection. Verify IP address configuration and network settings in the operating system.
    Event ID: 500
    Hard disk or storage media error detected; read/write failure on the system drive.
    Run a disk check utility. Replace the hard disk or CompactFlash card if errors persist. Restore the OS image from backup.
    Event ID: 600
    USB device not recognized or USB interface fault detected.
    Disconnect and reconnect the USB device. Try an alternative USB port. Check device driver installation in the operating system.
    Event ID: 700
    Display or backlight failure; screen remains dark or shows distorted image.
    Check 24 V DC supply voltage. Inspect the display cable connections internally. Replace the backlight inverter or display unit if the fault persists.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AE30-0AG0?

    The SIMATIC Panel PC 670 6AV7612-0AE30-0AG0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.

    What display size and resolution does this Panel PC have?

    This unit features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA), suitable for detailed process visualization and HMI graphics.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AE30-0AG0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial panel installation.

    Is this Panel PC compatible with Siemens WinCC software?

    Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other Windows-based SCADA and visualization software, as it operates on an industrial Windows platform.

    What communication interfaces are available on this unit?

    The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces, enabling connectivity to PLCs, networks, and peripheral devices.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power input connector. Check for blown internal fuses or a faulty power supply module.

    Ensure the supply voltage is stable and within the 24 V DC specification. Replace any blown fuses. If the internal power supply module is faulty, replace it with the correct Siemens spare part.

    Display remains blank or backlight does not illuminate

    Verify that the unit is powered on by checking for LED indicators or fan activity. Inspect the display cable connection between the mainboard and the display panel.

    Replace the backlight inverter board if the backlight is confirmed faulty. If the display cable is loose or damaged, reseat or replace it. Replace the TFT display panel if no image is produced after these checks.

    Touchscreen does not respond or registers incorrect touch positions

    Check if the touch controller is recognized in the operating system device manager. Verify that the touchscreen calibration has not been corrupted.

    Recalibrate the touchscreen using the Siemens calibration utility or the Windows control panel. If the touch controller is not recognized, reinstall the touch driver. Replace the touchscreen overlay if physical damage is present.

    Unit freezes or reboots unexpectedly during operation

    Check the operating temperature of the unit and inspect ventilation openings for blockage. Review the Windows event log for application errors or hardware faults.

    Clean ventilation slots and ensure ambient temperature is within the 0 °C to +45 °C operating range. Update or reinstall the SCADA application. If the issue is hardware-related, test the RAM modules and replace if faulty.

    Ethernet communication is lost or cannot be established

    Check the Ethernet cable and verify link LEDs on the RJ45 port. Confirm the IP address configuration in the operating system network settings.

    Replace the Ethernet cable if damaged. Reconfigure the IP address and subnet mask to match the network. If the onboard Ethernet controller is faulty, install a compatible PCIe or PCI network adapter as a replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart