• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE30-0AE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE30-0AE0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE30-0AE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE30-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit combines a high-performance computing platform with a robust industrial enclosure, providing a complete operator station solution.

    The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation. It is equipped with an Intel Celeron or Pentium processor depending on the configuration, and runs Microsoft Windows XP Professional or Windows 2000 as its operating system. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is designed for integration with Siemens SIMATIC WinCC and ProTool/Pro visualization software. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC-based HMI platform is required. Its industrial-grade construction makes it suitable for installation in control cabinets and operator panels in industries such as automotive, food and beverage, chemical processing, and general factory automation. The ability to run standard Windows-based SCADA and HMI software makes it a flexible platform for complex visualization and data logging requirements.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 80 W
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), USB 2.0, RS-232 (COM ports)
    Operating System Windows XP Professional / Windows 2000
    Mounting Panel mounting
    Certifications CE, UL
    Series/Product Family SIMATIC Panel PC 670

    Common Error Codes & System Events

    Event ID: 1000
    Application error in WinCC or HMI runtime software causing an unexpected process termination.
    Check the Windows Event Viewer for detailed error logs. Reinstall or repair the WinCC/ProTool runtime software if necessary.
    Event ID: 7034
    A system service terminated unexpectedly, often related to the SIMATIC HMI service or a communication driver.
    Restart the affected service via Windows Services Manager. If recurring, check for software conflicts or corrupted service files and reinstall drivers.
    BSOD (Stop Error)
    Windows Blue Screen of Death indicating a critical system or hardware fault, such as a driver conflict or memory error.
    Note the stop code displayed. Check RAM integrity, update or roll back drivers, and verify hardware connections. Replace RAM module if memory errors are confirmed.
    No Signal / Display Error
    The display shows no image or backlight fails after power-on, indicating a backlight or inverter fault.
    Check 24 V DC supply voltage at the power connector. Inspect the backlight inverter board and replace the CCFL backlight or inverter if the panel receives power but shows no image.
    Touchscreen Not Responding
    The resistive touchscreen does not register input or is misaligned, indicating calibration loss or controller fault.
    Recalibrate the touchscreen using the Windows control panel or Siemens calibration utility. If unresponsive, check the touchscreen controller connection internally and replace the touch overlay if damaged.
    Communication Timeout
    Loss of communication between the Panel PC and the connected PLC or field devices via Ethernet or serial interface.
    Verify network cable integrity and IP address configuration. Check PLC communication settings and ensure the correct communication driver is installed and running in WinCC or ProTool.
    Hard Disk Failure Warning
    S.M.A.R.T. diagnostic warning or Windows disk error indicating impending or current hard disk drive failure.
    Immediately back up all project data and the operating system image. Replace the internal hard disk drive with a compatible unit and restore the system image or perform a fresh installation.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7612-0AE30-0AE0?

    The unit operates on 24 V DC supply voltage. Ensure a stable and adequately rated DC power supply is used to prevent system instability.

    What HMI software is compatible with the SIMATIC Panel PC 670?

    The Panel PC 670 is compatible with Siemens SIMATIC WinCC and ProTool/Pro visualization software. It runs a standard Windows operating system, so other Windows-compatible SCADA packages can also be used.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AE30-0AE0 carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.

    Can the internal hard disk drive be replaced or upgraded?

    Yes, the internal hard disk drive is a standard industrial IDE or SATA drive depending on the revision, and can be replaced. It is recommended to create a system image backup before replacement to restore the operating system and project data.

    Is the touchscreen resistive or capacitive?

    The SIMATIC Panel PC 670 uses a resistive touchscreen technology, which can be operated with gloves or stylus and is suitable for industrial environments.

    Troubleshooting

    Panel PC does not power on after switching on the 24 V DC supply

    Measure the 24 V DC supply voltage at the power input connector to confirm correct voltage level. Check for any blown internal fuses on the power supply board.

    Ensure the supply voltage is within the specified 24 V DC range. Replace any blown fuses with the correct rating. If the internal power supply board is faulty, replace the power supply module.

    Display is blank or backlight does not illuminate despite the PC appearing to run

    Check whether the PC is booting normally by connecting an external monitor via the VGA port if available. Inspect the backlight inverter and CCFL lamp condition.

    If the system boots normally on an external display, the backlight inverter or CCFL lamp has failed. Replace the backlight inverter board or the CCFL lamp assembly. If no output on either display, suspect the graphics adapter or mainboard.

    WinCC or ProTool runtime fails to start or crashes repeatedly on boot

    Check the Windows Event Viewer for application error logs. Verify that the software license (dongle or software key) is present and valid. Check available hard disk space.

    Reinstall or repair the WinCC or ProTool runtime software. Ensure the software license is correctly installed. Free up disk space if the drive is near capacity, and check the hard disk for errors using Windows CHKDSK.

    Ethernet communication to PLC is lost intermittently or permanently

    Check the Ethernet cable and RJ45 connector for physical damage. Verify the IP address configuration in Windows network settings. Use ping to test connectivity to the PLC.

    Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network requirements. If the onboard Ethernet port is faulty, install a compatible PCIe or PCI Ethernet adapter card as a replacement.

    Touchscreen calibration is lost after reboot or touch input is inaccurate

    Determine whether the calibration data is being saved correctly to the hard disk. Check if the touchscreen controller driver is installed and functioning in Windows Device Manager.

    Recalibrate the touchscreen using the Siemens calibration utility or Windows Tablet PC settings. If calibration is repeatedly lost, the hard disk may have a write error or the touchscreen controller may be faulty and require replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart