• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE12-0BH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE12-0BH0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE12-0BH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE12-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit integrates a flat-panel display with a built-in computing platform, offering a compact all-in-one solution for process visualization and control.

    The SIMATIC Panel PC 670 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows operating systems, providing compatibility with standard SCADA and HMI software packages including WinCC and WinCC flexible. The unit offers multiple communication interfaces including Ethernet (RJ45) and serial ports, and is built to withstand industrial environments with a front panel protection rating of IP65.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building applications where a robust, panel-mounted computing solution is required. Its compatibility with Siemens SIMATIC software and standard industrial communication protocols makes it suitable for integration into existing SIMATIC automation architectures. Typical deployment scenarios include control cabinet front panels, operator stations on production lines, and supervisory control workstations in process plants.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Processor Intel Celeron
    Input/Operating Voltage 24 V DC
    Front Protection Rating IP65
    Rear Protection Rating IP20
    Communication Interface Ethernet (RJ45), RS-232, RS-422/485
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC Panel PC 670

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST sequence.
    Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty.
    Event ID: 200
    Fan failure or thermal management warning indicating cooling system malfunction.
    Inspect and clean the cooling fan. Ensure ventilation clearances are maintained. Replace the fan unit if it is not operating correctly.
    Event ID: 300
    Watchdog timeout error indicating the application software has stopped responding.
    Restart the application software. Check for software conflicts or memory issues. Update or reinstall the HMI runtime software if the problem persists.
    Event ID: 400
    Ethernet communication fault indicating loss of network connectivity.
    Check Ethernet cable connections and network switch status. Verify IP address configuration. Replace Ethernet cable or network adapter if hardware fault is confirmed.
    Event ID: 500
    Touch screen calibration error or touch input not responding correctly.
    Perform touch screen recalibration via the Windows control panel or SIMATIC configuration tool. Clean the touch surface. Replace the touch screen assembly if calibration fails repeatedly.
    Event ID: 600
    Power supply undervoltage condition detected on the 24 V DC input.
    Measure the 24 V DC supply voltage at the input connector. Ensure supply is within the specified tolerance. Check wiring and power supply unit output.
    Event ID: 700
    Hard disk or storage media error indicating read/write failure or device not detected.
    Check seating of the hard disk or CompactFlash card. Run disk diagnostics. Replace storage media and restore the operating system image if necessary.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 (6AV7612-0AE12-0BH0) support?

    The SIMATIC Panel PC 670 supports Microsoft Windows operating systems, including Windows XP Professional and Windows 2000, depending on the configuration ordered. It is compatible with Siemens WinCC and WinCC flexible HMI software.

    What is the supply voltage for the 6AV7612-0AE12-0BH0?

    The unit operates on a 24 V DC supply voltage, which is the standard supply for SIMATIC Panel PC 670 devices.

    What is the front panel protection rating of this Panel PC?

    The front panel of the 6AV7612-0AE12-0BH0 carries an IP65 protection rating, making it suitable for panel mounting in environments where dust and water spray may be present.

    Can the SIMATIC Panel PC 670 run third-party SCADA software?

    Yes, because the Panel PC 670 runs a standard Windows operating system, it is compatible with third-party SCADA and visualization software in addition to Siemens WinCC products.

    What communication interfaces are available on this unit?

    The 6AV7612-0AE12-0BH0 provides Ethernet (RJ45), RS-232, and RS-422/485 serial communication interfaces, enabling connectivity to PLCs, drives, and network infrastructure.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the input connector. Verify that the power LED indicator is illuminated. Measure voltage at the internal power supply output.

    Ensure the 24 V DC supply is within tolerance and correctly wired. If the supply is correct but the display remains blank, the internal power supply board or backlight inverter may be faulty and should be replaced.

    Touch screen does not respond or registers incorrect touch positions

    Attempt to recalibrate the touch screen through the Windows control panel or SIMATIC configuration utility. Inspect the touch surface for damage or contamination.

    Clean the touch screen surface with a soft, dry cloth. Perform a full touch screen recalibration. If the problem persists after recalibration, the touch screen overlay or controller board may need replacement.

    Unit fails to boot or displays a boot error message

    Check the CompactFlash card or hard disk for correct seating. Attempt to boot from an external device to determine if the storage media is faulty. Review BIOS POST messages for specific error indications.

    Reseat the storage media. If the storage device is confirmed faulty, replace it and restore the operating system image using the Siemens recovery media or a verified backup image.

    Ethernet communication is lost or intermittent

    Verify the Ethernet cable connection at both the Panel PC and the network switch. Check the IP address configuration in Windows network settings. Test the cable with a cable tester.

    Replace the Ethernet cable if found faulty. Reconfigure the IP address settings if there is an address conflict. If the network adapter is not detected, update the network driver or replace the Panel PC mainboard.

    Panel PC runs slowly or application software freezes

    Check CPU and memory utilization in Windows Task Manager. Inspect the storage media for available free space and file system errors. Verify that the cooling fan is operating and that the unit is not overheating.

    Close unnecessary background applications and services. Run a disk check utility to repair file system errors. Clean the cooling fan and ensure adequate ventilation. If overheating is confirmed, replace the cooling fan assembly.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart