• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE12-0BJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE12-0BJ0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE12-0BJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE12-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a high-performance computing platform with a robust industrial enclosure suitable for direct panel integration.

    The SIMATIC Panel PC 670 6AV7612-0AE12-0BJ0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch technology for operator input. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), enabling integration with a wide range of controllers and field devices. It supports PROFIBUS and Industrial Ethernet connectivity for seamless integration into Siemens automation architectures.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a full PC-based HMI platform is required. Its rugged construction and fanless or low-maintenance cooling options make it suitable for continuous operation in factory floor environments. Industries such as automotive, food and beverage, chemical processing, and packaging rely on this platform for supervisory control, data acquisition, and complex visualization tasks.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT Color LCD
    Touch Technology Resistive Touch Screen
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 60 W
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet (RJ45), USB 2.0, RS-232, RS-422/RS-485
    Bus System Compatibility PROFIBUS, Industrial Ethernet
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the Panel PC failed to complete the boot sequence correctly.
    Check power supply voltage (24 V DC), verify all internal connections, and inspect the CompactFlash card or hard disk for corruption. Reload or restore the operating system image if necessary.
    Event ID: 101
    Operating system not found or boot device inaccessible.
    Check the storage medium (CompactFlash or HDD) for proper seating and integrity. Replace the storage medium and reinstall the OS if the device is not detected.
    Event ID: 200
    Ethernet communication failure — loss of network connection detected.
    Verify Ethernet cable connections and network switch status. Check IP address configuration and ensure the correct network adapter driver is installed under the Windows device manager.
    Event ID: 300
    PROFIBUS communication error — no communication with connected PROFIBUS devices.
    Check PROFIBUS cable wiring, termination resistors, and bus address settings. Verify that the CP card or integrated PROFIBUS interface is correctly configured in the HMI software.
    Event ID: 400
    Touch screen not responding or calibration lost.
    Recalibrate the touch screen using the Windows touch screen calibration utility. If the issue persists, check the touch controller ribbon cable connection internally or replace the touch overlay.
    Event ID: 500
    Watchdog timeout — the system software did not respond within the expected time window.
    Restart the Panel PC. If the fault recurs, check for excessive CPU load, software conflicts, or memory issues. Update or reinstall the HMI application software.
    Event ID: 600
    Fan failure or overtemperature warning — internal temperature has exceeded the operating threshold.
    Check that ventilation slots are not blocked. Verify fan operation if applicable. Ensure ambient temperature is within the specified 0 °C to +50 °C range. Clean any dust from air vents.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 6AV7612-0AE12-0BJ0 run?

    This Panel PC is designed to run Microsoft Windows XP Embedded or Windows XP Professional, and is compatible with Siemens SIMATIC WinCC and WinCC flexible HMI software packages.

    What is the supply voltage for the 6AV7612-0AE12-0BJ0?

    The unit operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC products intended for industrial panel installation.

    What is the front panel protection rating of this Panel PC?

    The front panel of the 6AV7612-0AE12-0BJ0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.

    Can this Panel PC communicate with Siemens S7 PLCs?

    Yes, the Panel PC 670 supports Industrial Ethernet and PROFIBUS communication, allowing direct connectivity to Siemens S7-300, S7-400, and S7-1500 series PLCs using standard Siemens communication drivers.

    What display size and resolution does the 6AV7612-0AE12-0BJ0 have?

    This unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen for operator input.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power connector to confirm correct voltage level. Check for blown internal fuses and inspect the power supply module.

    Ensure the supply voltage is stable at 24 V DC. Replace any blown fuses with the correct rating. If the internal power supply module is faulty, replace it with a compatible Siemens spare part.

    Display remains blank or shows no image after boot

    Check whether the system is booting by listening for hard disk activity or connecting an external monitor if supported. Verify the display backlight by shining a light at the screen to detect a faint image.

    If the backlight has failed, replace the CCFL backlight or the complete display assembly. If the system is not booting, troubleshoot the storage medium and operating system as described in the startup error procedure.

    Touch screen input is inaccurate or unresponsive

    Attempt to recalibrate the touch screen through the Windows Control Panel or the Siemens-provided calibration tool. Check for physical damage or contamination on the touch overlay surface.

    Clean the touch screen surface with a soft, dry cloth. Recalibrate using the system calibration utility. If the touch controller hardware is defective, replace the touch screen overlay or the complete front panel assembly.

    Loss of Ethernet network communication

    Check the Ethernet cable and RJ45 connector for physical damage. Verify the network configuration (IP address, subnet mask, gateway) in Windows Network Settings. Check the status LEDs on the Ethernet port.

    Replace the Ethernet cable if damaged. Reconfigure the network settings to match the plant network. If the onboard Ethernet adapter is faulty, install a compatible USB-to-Ethernet adapter or replace the motherboard.

    HMI application crashes or freezes during operation

    Check available RAM and CPU usage using Windows Task Manager. Review the Windows Event Viewer for application or system errors. Verify that the CompactFlash card or HDD has sufficient free space and no file system errors.

    Close unnecessary background applications to free system resources. Run a disk check (chkdsk) to repair file system errors. If the storage medium is failing, back up the system image and replace the CompactFlash card or HDD, then restore the image.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart