Siemens 6AV7612-0AB32-0CJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB32-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface applications, combining computing performance with a robust industrial enclosure. This unit integrates a display, processing unit, and I/O interfaces into a single compact panel-mount device suitable for use in industrial control cabinets and machine fronts.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP or Windows 2000 as its operating system, providing a familiar PC environment for SCADA and visualization software. The unit offers standard PC interfaces including USB, serial (COM), parallel, and Ethernet ports, and supports expansion via PCI slots for additional communication or I/O cards. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC-based HMI platform is required. It is compatible with Siemens WinCC, WinCC flexible, and other SCADA software packages, making it suitable for integration into SIMATIC automation environments. Industries such as automotive, food and beverage, chemical processing, and general machine building commonly deploy this panel PC for supervisory control and data visualization tasks.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Processor | Intel Celeron |
| Operating System | Microsoft Windows XP / Windows 2000 |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front panel) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM), Parallel |
| Expansion | PCI slot(s) for expansion cards |
| Mounting | Panel mount |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat memory modules. Replace storage media if corrupted. - Event ID: 200
- Watchdog timeout — the application software has stopped responding
Restart the application. Check for software conflicts or resource overloads. Update or reinstall the HMI runtime software. - Event ID: 300
- Fan failure or thermal warning — internal temperature exceeding threshold
Check and clean cooling fan and ventilation slots. Verify ambient temperature is within specification. Replace fan if faulty. - Event ID: 400
- 24 V DC supply undervoltage detected
Measure supply voltage at the power input connector. Ensure power supply output is stable at 24 V DC within tolerance. Replace power supply if out of range. - Event ID: 500
- Ethernet communication link failure
Check Ethernet cable connection and network switch. Verify IP address configuration in Windows network settings. Replace cable or network card if hardware fault is confirmed. - Event ID: 600
- Touch screen calibration error or touch input not responding
Recalibrate the touch screen via the Windows control panel or SIMATIC configuration tool. Clean the touch surface. Replace touch screen controller if calibration fails repeatedly. - Event ID: 700
- Hard disk or CompactFlash storage device not detected
Reseat the storage device. Check for physical damage to the connector. Replace the hard disk or CompactFlash card and reinstall the operating system and application software.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AB32-0CJ0?
The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage, which is standard for industrial panel-mount devices.
What operating system does this Panel PC support?
The 6AV7612-0AB32-0CJ0 supports Microsoft Windows XP and Windows 2000, providing a standard PC environment for running SCADA and HMI software.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and WinCC flexible visualization software, making it suitable for integration into SIMATIC automation systems.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AB32-0CJ0 carries an IP65 protection rating, providing full dust protection and resistance to water jets.
Can this Panel PC be expanded with additional communication cards?
Yes, the SIMATIC Panel PC 670 includes PCI expansion slot(s) that allow installation of additional communication or I/O cards to extend the unit's connectivity options.
Troubleshooting
Panel PC does not boot or display remains blank after power on
Check that the 24 V DC supply is present and within tolerance at the power input. Verify that the power LED is illuminated. Listen for POST beep codes indicating hardware failure.
Ensure the power supply is stable at 24 V DC. Reseat RAM modules and storage device. If the unit still does not boot, replace the CompactFlash card or hard disk and reinstall the operating system.
Touch screen does not respond or registers incorrect touch positions
Attempt to operate the unit using a USB mouse to determine if the issue is isolated to the touch screen. Check Device Manager in Windows for touch controller errors.
Recalibrate the touch screen using the Windows control panel or the SIMATIC calibration utility. Clean the screen surface. If the problem persists, replace the touch screen controller or digitizer assembly.
Unit overheats or shuts down unexpectedly
Check the ambient temperature around the panel PC and verify it is within the 0 to 45 °C operating range. Inspect the cooling fan for operation and check ventilation slots for blockage.
Clean dust from ventilation slots and the cooling fan. Ensure adequate clearance around the unit for airflow. Replace the internal cooling fan if it is not spinning. Reduce ambient temperature if necessary.
Ethernet communication is not established
Check the Ethernet cable connection and verify the link LED on the RJ45 port is active. Confirm the IP address and network settings in Windows are correctly configured for the target network.
Replace the Ethernet cable and test with a known-good network switch port. Reconfigure the IP address settings if required. If the network adapter is not detected in Device Manager, reinstall the driver or replace the network card.
Application software crashes or freezes during operation
Check Windows Event Viewer for application or system error logs. Monitor CPU and memory usage to identify resource exhaustion. Verify that the installed software version is compatible with the operating system.
Restart the HMI application. Update or reinstall the runtime software. If crashes persist, check for hard disk errors using Windows disk utilities and replace the storage device if errors are found.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page