
Siemens 6AV7612-0AE10-0AE0 Mobile Panel 170
€ 2.007,00
The Siemens 6AV7612-0AE10-0AE0 is a Mobile Panel 170, part of the SIMATIC HMI Mobile Panel family. This handheld operator panel is designed for flexible, mobile human-machine interface applications where the operator needs to move freely around a machine or plant area. It provides a compact, rugged touchscreen interface for monitoring and controlling industrial processes directly from the field.
The Mobile Panel 170 features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA), supporting up to 256 colors. It is equipped with a resistive touchscreen and includes function keys for additional operator input. The unit communicates via PROFIBUS DP, enabling integration with Siemens S7 PLCs and other PROFIBUS-compatible controllers. It includes an enabling button (three-position safety switch) and an emergency stop button, making it suitable for safety-relevant applications. The panel is configured using WinCC flexible or ProTool software and features 512 KB of user memory for project data.
The Mobile Panel 170 is widely used in manufacturing, automotive assembly, machine tool, and packaging industries where operators must interact with equipment from multiple positions. Its integrated safety features, including the enabling device and emergency stop, make it particularly suited for setup, maintenance, and commissioning tasks on large or complex machinery. The handheld form factor and robust construction allow reliable operation in demanding industrial environments.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Colors | 256 colors |
| Display Type | STN color |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 8 W |
| Communication Interface | PROFIBUS DP |
| User Memory | 512 KB |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front) |
| Safety Features | Three-position enabling button, Emergency stop button |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC HMI Mobile Panel |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the Mobile Panel and the connected PLC or PROFIBUS network. The panel cannot establish or maintain a connection to the controller.
Check the PROFIBUS cable connection and termination resistors. Verify the PROFIBUS address settings on both the panel and the PLC. Ensure the PLC is in RUN mode and the network is correctly configured. - Event ID: 10001
- Project download error. The configuration project could not be transferred to the Mobile Panel successfully.
Check the transfer cable connection and ensure the panel is in Transfer mode. Verify that the WinCC flexible or ProTool project is compatible with the Mobile Panel 170 firmware version. - Event ID: 20000
- System fault detected. An internal system error has occurred in the Mobile Panel.
Restart the Mobile Panel by cycling power. If the fault persists, perform a factory reset and re-download the project. Contact Siemens technical support if the error recurs. - Event ID: 20001
- Memory error. The panel has detected a fault in the user memory or project data storage area.
Re-download the project to the panel. If the error persists, the internal memory may be corrupted or faulty and the unit may require repair or replacement. - Event ID: 40000
- Enabling button not actuated or released. The three-position enabling device is not in the enabled (middle) position, preventing operation in enabling-dependent modes.
Ensure the operator is pressing the enabling button to the middle (enabled) position. Check the enabling button mechanism for mechanical damage or contamination. - Event ID: 40001
- Emergency stop activated. The integrated emergency stop button on the Mobile Panel has been pressed.
Identify and resolve the cause of the emergency stop activation. Unlock the emergency stop button by rotating it, then reset the safety circuit from the controller before resuming operation. - Communication Error
- Loss of connection to the PROFIBUS DP master during operation. The panel detects a bus interruption or timeout.
Inspect the PROFIBUS cable for damage, loose connectors, or missing termination. Check the bus topology and ensure all node addresses are unique and correctly assigned. - Configuration Error
- The loaded project configuration does not match the connected PLC or hardware configuration, causing tag or address mapping failures.
Verify that the PLC program and HMI project use matching variable addresses and data types. Re-download a corrected project after resolving address conflicts in WinCC flexible or ProTool.
Frequently Asked Questions
What communication interface does the Mobile Panel 170 (6AV7612-0AE10-0AE0) use?
The Mobile Panel 170 communicates via PROFIBUS DP, allowing direct connection to Siemens S7-300, S7-400 PLCs, and other PROFIBUS-compatible controllers.
Which software is used to configure and program this Mobile Panel?
The Mobile Panel 170 is configured using Siemens WinCC flexible or the older ProTool software. Projects are downloaded to the panel via the serial transfer interface.
Does this Mobile Panel include safety features such as an emergency stop?
Yes, the 6AV7612-0AE10-0AE0 includes an integrated three-position enabling button (dead man's switch) and an emergency stop button, making it suitable for safety-relevant setup and maintenance operations.
What is the operating voltage for the Mobile Panel 170?
The unit operates on 24 V DC, supplied through the connecting cable from the docking station or a suitable power supply.
What is the IP protection rating of the Mobile Panel 170?
The front face of the Mobile Panel 170 is rated IP65, providing protection against dust ingress and low-pressure water jets, suitable for typical industrial environments.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the panel connector. Inspect the connecting cable for damage or broken pins. Verify the power supply output voltage under load.
Replace or reseat the connecting cable. If voltage is confirmed at the connector but the display remains off, the internal power supply or display backlight may be faulty and the unit requires repair.
No communication with PLC over PROFIBUS
Verify the PROFIBUS address configured on the Mobile Panel matches the address expected in the PLC hardware configuration. Check cable continuity and termination resistors at both ends of the PROFIBUS segment.
Correct the PROFIBUS node address on the panel if mismatched. Replace damaged cable or connectors. Ensure termination resistors are enabled only at the two physical ends of the PROFIBUS network.
Touchscreen does not respond or responds inaccurately
Check for physical damage or contamination on the touchscreen surface. Determine if the issue is present across the entire screen or only in specific areas, which may indicate a damaged digitizer.
Clean the touchscreen surface with a soft, dry cloth. Perform a touchscreen recalibration from the panel's system settings menu. If inaccuracy persists, the resistive touchscreen digitizer may require replacement.
Project cannot be downloaded to the panel
Confirm the panel is set to Transfer mode before initiating the download. Check the transfer cable connection between the PC and the panel. Verify that the WinCC flexible project version is compatible with the panel firmware.
Switch the panel to Transfer mode via the Start Center menu. Replace the transfer cable if faulty. Update the panel firmware if a version mismatch is identified, then re-attempt the project download.
Enabling button does not allow operation in setup mode
Check whether the enabling button is being pressed to the correct middle (enabled) position. Inspect the button mechanism for mechanical wear, contamination, or damage that may prevent correct actuation.
Clean the enabling button area and test actuation through all three positions. If the button does not register the middle position correctly, the enabling device mechanism is likely worn and the unit should be sent for repair.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page



