• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB32-0BF0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AB32-0BF0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB32-0BF0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB32-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC platform, providing both operator interface and computing functionality in a single compact device.

    The SIMATIC Panel PC 670 6AV7612-0AB32-0BF0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an industrial-grade PC architecture running on a Windows-based operating system, with support for standard PC interfaces including USB, serial (RS-232), and Ethernet ports for connectivity to PLCs and SCADA systems. The unit is designed for front-panel mounting with an IP65-rated front face, protecting against dust and water ingress in industrial environments. It supports SIMATIC WinCC and other Siemens HMI software platforms for process visualization.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, panel-integrated PC solution is required. Its combination of a touch-enabled display and full PC functionality makes it suitable for complex visualization tasks, recipe management, data logging, and integration with SIMATIC S7 PLC systems. Industries such as automotive, food and beverage, chemical processing, and discrete manufacturing commonly deploy this panel PC for supervisory control and operator workstation applications.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), RS-232, USB
    Mounting Panel mounting (front flush mount)
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating System Windows XP Embedded / Windows 2000

    Common Error Codes and System Events

    Event ID: 1000
    Application error — a software application on the Panel PC has encountered an unexpected fault and terminated.
    Check the Windows Event Viewer for detailed error logs. Restart the affected application or reinstall the HMI software (e.g., WinCC) if the error persists.
    Event ID: 7034
    Service terminated unexpectedly — a critical Windows service has stopped running without a controlled shutdown.
    Review the System Event Log for the specific service name. Restart the service manually via Windows Service Manager or reboot the Panel PC.
    BIOS POST Error
    Hardware self-test failure detected during power-on — may indicate a RAM, CPU, or hardware component fault.
    Power cycle the unit. If the error persists, reseat RAM modules and check internal hardware connections. Contact Siemens service if hardware replacement is required.
    WinCC Runtime Error
    WinCC runtime process has failed to start or has crashed, preventing HMI visualization from loading.
    Check WinCC project configuration for corruption. Reinstall WinCC runtime if necessary and verify license dongle or software license is present and valid.
    Network Connection Lost
    Ethernet communication to the PLC or SCADA server has been interrupted.
    Check Ethernet cable and switch connections. Verify IP address configuration in Windows Network Settings and confirm PLC communication settings match the project configuration.
    Hard Disk Error
    The internal hard disk or CompactFlash storage device has reported a read/write error or is not detected.
    Check BIOS to confirm the storage device is detected. Back up project data immediately. Replace the hard disk or CompactFlash card and restore the HMI project from backup.
    Watchdog Timeout
    The hardware watchdog timer has triggered a system reset due to the operating system or application becoming unresponsive.
    Investigate CPU load and running processes for resource exhaustion. Optimize the HMI application or upgrade memory if system resources are insufficient.

    Frequently Asked Questions

    What display size and resolution does the 6AV7612-0AB32-0BF0 have?

    This Panel PC features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen interface.

    What is the supply voltage for the SIMATIC Panel PC 670 6AV7612-0AB32-0BF0?

    The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 series devices.

    Is this Panel PC compatible with Siemens WinCC HMI software?

    Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other SIMATIC HMI software packages, and it supports connectivity to SIMATIC S7 PLCs via Ethernet or serial interfaces.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AB32-0BF0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial panel installation.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), RS-232 serial, and USB ports, enabling connectivity to PLCs, SCADA systems, and peripheral devices.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply connector. Verify the display backlight is functioning by shining a light at the screen to check for a faint image.

    If 24 V DC is confirmed but the display is blank, the backlight inverter or CCFL backlight may have failed. Replace the backlight assembly or the display unit. If no voltage is present, check the power supply and wiring.

    Touch screen does not respond or is inaccurate

    Attempt to recalibrate the touch screen through the Windows control panel or SIMATIC touch calibration utility. Check for physical damage or contamination on the screen surface.

    Run the touch screen calibration routine. Clean the screen surface with a soft cloth. If calibration fails repeatedly, the resistive touch overlay may be damaged and requires replacement.

    Panel PC fails to boot or freezes during startup

    Observe the boot sequence for BIOS POST errors or Windows startup errors. Check if the hard disk or CompactFlash storage is detected in the BIOS settings.

    If the storage device is not detected, reseat or replace the hard disk or CompactFlash card. Restore the operating system and HMI project from a backup image. If the unit freezes post-BIOS, check RAM seating and integrity.

    Loss of communication with SIMATIC S7 PLC

    Verify Ethernet cable integrity and switch port status. Ping the PLC IP address from the Panel PC command prompt to test network connectivity. Check WinCC or HMI project communication settings.

    Replace the Ethernet cable if faulty. Confirm IP address, subnet mask, and gateway settings are correctly configured. Reload the HMI project communication configuration if settings have been corrupted.

    WinCC runtime does not start after Windows boot

    Check the Windows Event Viewer for application or system errors related to WinCC. Verify that the WinCC license or dongle is present and recognized by the system.

    Reinstall the WinCC runtime software if corrupted. Ensure the software license is valid and the hardware dongle is properly connected. Check that all required WinCC services are set to start automatically in Windows Service Manager.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart