
Siemens 6AV7612-0AB32-0BE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB32-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, providing a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 6AV7612-0AB32-0BE0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen for operator input. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard industrial communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), and is designed for panel mounting with a protection rating of IP65 on the front face.
This Panel PC is widely used in manufacturing, automotive, chemical processing, and food and beverage industries where a robust, integrated PC-based HMI solution is required. Its fanless or low-maintenance design and industrial-grade components make it suitable for continuous operation in environments with vibration, dust, and temperature variations. The device is commonly integrated into control cabinets or operator panels as the primary visualization and control interface for SIMATIC S7 PLC systems and distributed I/O networks.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Communication Interface | Ethernet (RJ45), USB, RS-232, RS-422/RS-485 |
| Operating System | Windows XP / Windows 2000 (factory configurable) |
| Processor | Intel Celeron |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup error or boot failure detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration in BIOS settings. - Event ID: 200
- Watchdog timeout triggered — the application software stopped responding within the defined monitoring interval.
Restart the Panel PC. Check the HMI application for software hangs or infinite loops. Update or reinstall the WinCC runtime software if the issue persists. - Event ID: 300
- Ethernet communication failure — loss of network connection to PLC or SCADA server.
Check Ethernet cable and switch/hub connections. Verify IP address configuration and network settings in the operating system. Check PLC communication driver settings. - Event ID: 400
- Touchscreen calibration error — touch input coordinates are misaligned or unresponsive.
Run the touchscreen calibration utility from the Windows Control Panel or SIMATIC configuration tool. Clean the touch surface and check for physical damage to the resistive overlay. - Event ID: 500
- Internal temperature warning — the Panel PC internal temperature has exceeded the recommended operating threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Verify that ventilation slots are not blocked. Inspect cooling components for dust accumulation. - Event ID: 600
- Hard disk or CompactFlash storage device read/write error detected.
Back up project data immediately. Run a disk check utility. Replace the CompactFlash card or hard disk drive if errors persist. - Event ID: 700
- USB device error — connected USB peripheral not recognized or communication interrupted.
Disconnect and reconnect the USB device. Try a different USB port. Verify driver compatibility with the installed operating system version. - Event ID: 800
- WinCC Runtime license error — valid runtime license not found or license key not recognized.
Check the SIMATIC software license using the Automation License Manager. Reinstall or transfer the license to the correct hardware dongle or storage location.
Frequently Asked Questions
What display size and resolution does the 6AV7612-0AB32-0BE0 have?
This Panel PC features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen for operator input.
What is the supply voltage for the SIMATIC Panel PC 670 6AV7612-0AB32-0BE0?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC industrial panel devices.
Is this Panel PC compatible with Siemens WinCC SCADA software?
Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and WinCC flexible HMI software, as well as other Windows-compatible SCADA and visualization applications.
What communication interfaces are available on this unit?
The 6AV7612-0AB32-0BE0 provides Ethernet (RJ45), USB ports, and serial interfaces (RS-232 and RS-422/RS-485) for connectivity to PLCs, networks, and peripheral devices.
What is the front panel protection rating of this device?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for panel-mounted installations in industrial environments.
Troubleshooting
Panel PC does not power on after 24 V DC supply is connected
Measure the 24 V DC supply voltage at the power input connector. Check for blown internal fuses or a faulty power supply module. Verify polarity of the DC supply connection.
Correct any wiring errors and ensure the supply voltage is within the specified range. Replace any blown fuses. If the internal power supply module is faulty, replace the module or send the unit for repair.
Display remains blank or shows no image after power on
Check whether the Panel PC completes its boot sequence by listening for hard disk activity or connecting an external monitor if supported. Verify the display backlight is functioning by shining a light at the screen surface.
If the backlight has failed, replace the CCFL backlight or the display assembly. If the unit boots but the display is blank, check display cable connections internally. Reinstall or restore the operating system if a software fault is suspected.
Touchscreen input is inaccurate or unresponsive
Determine whether the issue is a calibration problem or a hardware failure by observing if touch events register at all in the operating system. Check the touch controller driver status in Device Manager.
Run the touchscreen calibration utility from the Windows Control Panel. If the touchscreen remains unresponsive after calibration, check the internal ribbon cable connection between the touch overlay and the controller board. Replace the resistive touch overlay if physically damaged.
Ethernet communication to PLC is lost intermittently or permanently
Check the Ethernet cable and connector for physical damage. Verify the IP address and subnet mask settings in the operating system. Use the ping command to test connectivity to the PLC or network switch.
Replace the Ethernet cable if damaged. Reconfigure the network settings to match the PLC network. Update the Ethernet adapter driver if necessary. If the onboard Ethernet port is faulty, replace the network interface card or the mainboard.
Panel PC freezes or restarts unexpectedly during operation
Check the internal operating temperature using the BIOS or system monitoring tools. Review the Windows Event Log for application or system errors. Check the CompactFlash card or hard disk for errors using a disk check utility.
Ensure adequate ventilation and that ambient temperature is within the 0 to 45 °C operating range. Replace the storage medium if disk errors are found. Update or reinstall the HMI application software if software crashes are identified as the cause.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page



