Siemens 6AV7612-0AB23-0CJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB23-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC platform, providing both operator interface and computing functionality in a single device.
The 6AV7612-0AB23-0CJ0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology for reliable operator input. It is based on an Intel Celeron processor platform running Microsoft Windows XP Professional or Windows XP Embedded, and supports standard PC interfaces including USB, serial (RS-232), parallel, and Ethernet (RJ45). The unit is designed for front-panel mounting with an IP65 protection rating on the front face, making it suitable for use in environments where dust and water ingress are a concern. It operates on a 24 V DC supply voltage.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a robust, integrated PC-based HMI solution is required. Its compatibility with standard SCADA and HMI software packages such as Siemens WinCC makes it suitable for complex visualization tasks. Industries including automotive, food and beverage, chemical processing, and general manufacturing commonly deploy this panel PC for supervisory control and data acquisition at the machine or line level.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Display Colors | 262,144 colors |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet RJ45, USB, RS-232 (COM), Parallel (LPT) |
| Mounting | Front panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup error or boot failure detected during POST.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Restore or reinstall the operating system image if necessary. - Event ID: 200
- Fan failure or thermal warning — cooling fan not operating within specified speed range.
Inspect and clean the cooling fan. Replace the fan unit if it is not spinning or is running below rated speed to prevent thermal shutdown. - Event ID: 300
- Hard disk or storage media error — read/write failure on the internal storage device.
Back up data immediately. Run disk diagnostics. Replace the hard disk drive or CompactFlash card if errors persist. - Event ID: 400
- Ethernet communication failure — network interface not detected or link not established.
Check Ethernet cable connection and network switch. Verify network adapter settings in Device Manager. Replace cable or check network adapter driver installation. - Event ID: 500
- Touchscreen calibration error — touch input not responding correctly to screen coordinates.
Run the touchscreen calibration utility from the Windows control panel or Siemens HMI configuration tool. Clean the touch surface and recalibrate. - Event ID: 600
- Power supply undervoltage — supply voltage dropped below the 24 V DC operating threshold.
Measure the DC supply voltage at the panel PC power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance range. - Event ID: 700
- WinCC Runtime communication error — loss of connection between WinCC and the PLC or controller.
Check the communication cable and network settings. Verify PLC is online and reachable. Review WinCC channel diagnostics and restart the runtime application if necessary.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AB23-0CJ0?
The SIMATIC Panel PC 670 6AV7612-0AB23-0CJ0 operates on a 24 V DC supply voltage.
What operating system does this Panel PC run?
This unit supports Microsoft Windows XP Professional or Windows XP Embedded as the operating system, which is pre-installed or available as a software option from Siemens.
What is the front panel protection rating of this device?
The front panel of the 6AV7612-0AB23-0CJ0 carries an IP65 protection rating, providing protection against dust and water jets.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens WinCC SCADA and HMI software, which is one of its primary intended visualization platforms.
What communication interfaces are available on this unit?
The unit provides Ethernet (RJ45), USB ports, RS-232 serial (COM), and a parallel (LPT) port for peripheral and network connectivity.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator is active. Listen for fan operation to confirm the unit is receiving power.
Ensure the 24 V DC supply is stable and within tolerance. If the supply is correct but the display remains blank, check internal fuse and backlight inverter. The backlight or inverter board may require replacement if the unit powers on but the screen remains dark.
Touchscreen does not respond or responds inaccurately
Determine whether the issue is a complete lack of response or positional inaccuracy. Check for physical damage or contamination on the touch surface. Verify the touch controller driver is loaded correctly in Windows Device Manager.
Clean the touch surface with a soft, dry cloth. Run the touchscreen calibration utility in Windows. If the touchscreen remains unresponsive, check the internal ribbon cable connection between the touch panel and the controller board, or replace the touch panel assembly.
Unit fails to boot or continuously restarts
Observe the boot sequence on the display. Check if the BIOS POST completes and whether Windows begins to load. A failing hard disk or corrupted OS image is a common cause on older Panel PC 670 units.
Access the BIOS to verify the storage device is detected. Run disk diagnostics. If the storage medium is faulty, replace the hard disk drive or CompactFlash card and restore the operating system image using the Siemens recovery media.
Ethernet communication not established
Check the Ethernet cable and verify the link LED on the RJ45 port is active. Open Windows Device Manager to confirm the network adapter is recognized and drivers are installed without errors.
Replace the Ethernet cable and verify the network switch port is active. Reinstall the network adapter driver if it shows an error in Device Manager. Check IP address configuration and firewall settings within Windows.
Panel PC overheating or shutting down unexpectedly
Check the ambient temperature around the panel PC installation. Inspect the ventilation slots and cooling fan for blockage by dust or debris. Monitor CPU temperature using a system monitoring utility.
Clean all ventilation openings and the cooling fan using compressed air. Ensure the installation environment does not exceed the maximum operating temperature of 45 °C. Replace the cooling fan if it is not operating at the correct speed.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page