• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB30-0AE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AB30-0AE0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB30-0AE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB30-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit combines a flat-panel display with an integrated PC platform, offering a compact and rugged all-in-one solution for process visualization and control.

    The SIMATIC Panel PC 670 6AV7612-0AB30-0AE0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology. It is powered by an Intel Celeron processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is designed for front-panel mounting with an IP65 protection rating on the front face. Onboard memory and storage options support robust data logging and visualization applications.

    The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, food and beverage, and chemical processing industries. It is typically installed in control cabinets or operator stations where a full PC-based HMI platform is required, enabling complex SCADA and visualization applications. Its industrial-grade construction and compatibility with Siemens automation software make it suitable for integration into SIMATIC-based control architectures.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT Color LCD
    Touch Technology Resistive Touch Screen
    Processor Intel Celeron
    Operating Voltage 24 V DC
    IP Protection (Front) IP65
    Communication Interfaces Ethernet (RJ45), USB, RS-232
    Operating System Microsoft Windows
    Mounting Panel Mounting (front)
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly or a critical system file is missing.
    Check hard disk or CompactFlash integrity. Reinstall or restore the operating system image using the Siemens recovery partition or backup medium.
    Event ID: 1000
    Application fault — the HMI or SCADA application (e.g. WinCC) has crashed unexpectedly.
    Check Windows Event Viewer for detailed error logs. Reinstall or repair the HMI software. Verify software version compatibility with the Panel PC firmware.
    Event ID: 7000
    Service failed to start — a required Windows service did not start during boot, preventing normal HMI operation.
    Check Windows Event Viewer under System logs. Verify service dependencies and restart the service manually or reconfigure startup settings.
    Hardware Watchdog Timeout
    The hardware watchdog timer has triggered a system reset due to the operating system or application becoming unresponsive.
    Investigate the root cause of the system hang. Check for software conflicts, memory issues, or overheating. Update drivers and BIOS/firmware if applicable.
    Fan Failure Warning
    The internal cooling fan has failed or is operating below the minimum required speed, risking overheating.
    Replace the internal cooling fan. Ensure ventilation clearances around the panel are maintained per installation guidelines.
    Battery Low Warning
    The CMOS/RTC backup battery voltage is low, which may cause loss of BIOS settings and system clock errors after power loss.
    Replace the internal CMOS backup battery (typically CR2032 or equivalent). Re-enter BIOS settings and verify system date and time after replacement.
    Ethernet Link Down
    The Ethernet interface has lost its network connection, interrupting communication with PLCs or SCADA servers.
    Check Ethernet cable connections and switch/hub status. Verify network configuration (IP address, subnet mask). Test with a replacement cable.
    Display Backlight Failure
    The LCD backlight has failed or reached end of life, resulting in a dark or very dim display.
    Replace the backlight inverter or the display unit. Check the backlight power connector and cable for damage before replacing the full display assembly.

    Frequently Asked Questions

    What display size and resolution does the 6AV7612-0AB30-0AE0 have?

    The unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen.

    What is the supply voltage for the SIMATIC Panel PC 670 6AV7612-0AB30-0AE0?

    The Panel PC 670 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.

    Which HMI and SCADA software is compatible with this Panel PC?

    The 6AV7612-0AB30-0AE0 is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other Windows-based HMI and SCADA software packages.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AB30-0AE0 carries an IP65 protection rating, making it suitable for environments where dust and water spray may be present.

    Can the storage or operating system drive be replaced or upgraded?

    The SIMATIC Panel PC 670 supports CompactFlash or hard disk drive storage depending on the variant; the storage medium can be replaced or reimaged using Siemens-provided recovery tools.

    Troubleshooting

    Display remains blank after power on

    Measure 24 V DC supply voltage at the power input connector. Check if the power LED is illuminated. Determine whether the system is booting but the display is dark, or if there is no power at all.

    If power is present but display is blank, replace the backlight inverter or LCD assembly. If no power LED is visible, check the internal fuse and power supply board. Verify the 24 V DC source is within tolerance.

    Touch screen does not respond or is inaccurate

    Check if the touch screen is physically damaged or contaminated. In Windows Device Manager, verify the touch controller driver is installed and functioning. Attempt touch screen recalibration via the Windows control panel.

    Recalibrate the resistive touch screen using the Siemens or Windows calibration utility. If calibration fails, check the touch controller ribbon cable connection. Replace the touch screen overlay if the surface is damaged.

    System fails to boot or continuously restarts

    Observe the boot sequence on the display. Check for Windows error messages or BIOS POST errors. Inspect the CompactFlash card or hard disk for errors using diagnostic tools.

    Restore the operating system from the Siemens recovery partition or a backup image. If the storage medium is faulty, replace the CompactFlash card or hard disk and reinstall the OS and HMI software.

    Loss of network communication with PLC or SCADA server

    Check the Ethernet cable and switch port status. Verify the IP address configuration in Windows Network Settings. Ping the target PLC or server from the Panel PC command prompt.

    Replace the Ethernet cable if faulty. Reconfigure the IP address and subnet mask to match the network. If the onboard Ethernet port is defective, a USB-to-Ethernet adapter may be used as a temporary measure pending repair.

    BIOS settings reset after every power cycle

    This indicates the CMOS backup battery has discharged. After powering on, enter the BIOS setup and check if the date and time are incorrect or reset to default values.

    Replace the internal CMOS backup battery with the correct type (typically CR2032). After replacement, re-enter all BIOS settings including date, time, and boot order, then save and exit.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart