Siemens 6AV7612-0AB12-0BF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB12-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface and visualization tasks in automation environments. The unit combines a built-in display with a full PC architecture, enabling it to run SCADA, HMI, and process visualization software directly on the panel.
The SIMATIC Panel PC 670 features a 12.1-inch TFT display with 800 x 600 (SVGA) resolution and a resistive touchscreen interface. It is powered by an Intel Celeron processor and runs Microsoft Windows operating systems, supporting standard PC software including Siemens WinCC and SIMATIC software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces, and is built to withstand industrial environments with a front panel protection rating of IP65.
The 6AV7612-0AB12-0BF0 is widely deployed in manufacturing, process automation, and machine building applications where a full PC-based visualization platform is required. It is suitable for use in automotive production lines, chemical processing plants, and discrete manufacturing facilities. Its panel-mount design and industrial-grade construction make it appropriate for integration into control cabinets and operator stations requiring robust, long-term operation.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive Touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 65 W |
| Processor | Intel Celeron |
| Communication Interface | Ethernet (RJ45), USB, Serial (RS-232) |
| Operating System | Microsoft Windows XP / Windows 2000 |
| IP/Protection Rating | IP65 (front panel) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mount |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration. Replace storage media if corrupted. - Event ID: 200
- Watchdog timeout triggered, indicating the application or OS has become unresponsive.
Restart the Panel PC. Investigate the running application for memory leaks or infinite loops. Update or reinstall the HMI software if the issue persists. - Event ID: 300
- Ethernet communication link failure or network interface not detected.
Check Ethernet cable connection and network switch. Verify IP address configuration in the operating system. Replace Ethernet cable or check RJ45 port for damage. - Event ID: 400
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen using the Windows calibration utility. Clean the touch surface. If unresponsive, check internal touchscreen controller connection or replace the touchscreen assembly. - Event ID: 500
- Internal temperature exceeded operating threshold, thermal protection activated.
Check ambient temperature around the panel. Clean ventilation openings and ensure adequate airflow. Verify that the cooling fan (if fitted) is operational. - Event ID: 600
- Storage media (hard disk or CompactFlash) read/write error detected.
Run a disk check utility to identify bad sectors. Back up data immediately. Replace the hard disk or CompactFlash card if errors persist. - Event ID: 700
- Power supply voltage out of tolerance, undervoltage or overvoltage condition detected.
Measure the 24 V DC supply at the power connector. Ensure the supply is within the specified tolerance range. Replace or adjust the external power supply unit as required.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AB12-0BF0?
The unit operates on a 24 V DC supply voltage. Ensure the external power supply is within the specified tolerance range for reliable operation.
What display size and resolution does this Panel PC have?
The 6AV7612-0AB12-0BF0 is equipped with a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
What operating system does the SIMATIC Panel PC 670 support?
The Panel PC 670 supports Microsoft Windows XP and Windows 2000, allowing it to run standard PC-based HMI and SCADA software including Siemens WinCC.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AB12-0BF0 carries an IP65 protection rating, making it suitable for environments where dust and water jets may be present.
Is the touchscreen on this Panel PC resistive or capacitive?
The touchscreen on the SIMATIC Panel PC 670 is resistive type, which allows operation with gloved hands and is well-suited to industrial environments.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power connector with a multimeter. Check the internal fuse and verify the power supply unit output is within tolerance.
Replace the internal fuse if blown. If the supply voltage is correct and the unit still does not power on, the internal power supply board may require replacement or professional repair.
Display is blank or shows no image after boot
Check whether the PC is booting by listening for hard disk activity or connecting an external monitor via the VGA port if available. Verify backlight operation by shining a light on the screen surface.
If the PC boots but the display is blank, the backlight inverter or CCFL backlight lamp may have failed and should be replaced. If no boot activity is detected, investigate the storage media and OS integrity.
Touchscreen does not respond or registers incorrect touch positions
Attempt to recalibrate the touchscreen through the Windows control panel. Check for physical damage or contamination on the touch surface.
Recalibrate the touchscreen using the Windows touchscreen calibration tool. Clean the screen surface with a soft cloth. If calibration fails repeatedly, the touchscreen controller or touch overlay may need replacement.
Ethernet communication is not established
Check the Ethernet cable and verify the link LED on the RJ45 port is illuminated. Confirm the IP address settings in the Windows network configuration.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network requirements. If the link LED does not illuminate with a known-good cable, the network interface card may be faulty.
Unit reboots unexpectedly or freezes during operation
Check the operating temperature of the unit and the ambient environment. Review the Windows event log for application errors or hardware warnings. Verify the 24 V DC supply stability.
Ensure adequate ventilation and that ambient temperature is within the 0 to 50 °C operating range. Stabilize the power supply if voltage fluctuations are detected. Reinstall or update the HMI application software if software faults are identified in the event log.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page