
Siemens 6AV7612-0AB12-0BG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB12-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AB12-0BG0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 256,000 colors, providing clear visualization of process data. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting standard PC software environments. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), enabling integration with a wide range of automation and IT systems. It operates on a 24 V DC supply voltage and is built to meet industrial environmental requirements with an IP65-rated front panel for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building applications where a full PC-based HMI platform is required. It is suitable for use in automotive production lines, chemical processing plants, food and beverage facilities, and packaging machinery. The combination of a ruggedized enclosure, industrial-grade components, and compatibility with Siemens SIMATIC WinCC and other SCADA software makes it a reliable choice for complex visualization and data acquisition tasks.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 256,000 colors |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front panel) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM ports) |
| Operating System | Windows XP / Windows 2000 (compatible) |
| Processor | Intel Celeron |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup failure — the Panel PC fails to complete the boot sequence, often due to a corrupted operating system or failed storage medium.
Check the hard disk or CompactFlash card for errors. Reinstall or restore the operating system image using the Siemens recovery media. - Event ID: 200
- Watchdog timeout — the system watchdog has triggered due to a software hang or unresponsive application.
Restart the Panel PC. Investigate the running application for memory leaks or infinite loops. Update or reinstall the HMI runtime software. - Event ID: 300
- Ethernet communication failure — loss of network connectivity detected between the Panel PC and the controller or network.
Check Ethernet cable connections and network switch status. Verify IP address configuration and subnet settings in the operating system network settings. - Event ID: 400
- Runtime application error — the HMI visualization software (e.g., WinCC flexible Runtime) has encountered an unhandled exception and terminated.
Restart the runtime application. Check the application project for configuration errors. Ensure the runtime software version is compatible with the project version. - Event ID: 500
- Storage medium error — read/write errors detected on the internal hard disk or CompactFlash storage device.
Run a disk check utility (chkdsk) on the storage medium. Replace the hard disk or CompactFlash card if errors persist. Restore the system image from backup. - Event ID: 600
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the permissible operating range.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance. Check wiring and connections for voltage drops. - Event ID: 700
- Touch screen calibration error — the touch input is misaligned or unresponsive after a system restart or hardware change.
Run the touch screen calibration utility from the Windows Control Panel or Siemens-provided calibration tool. Clean the touch surface and recalibrate. - Event ID: 800
- Fan failure or overtemperature warning — the internal cooling fan has stopped or the system temperature has exceeded the permissible limit.
Check and clean the ventilation slots. Inspect and replace the internal cooling fan if faulty. Ensure the ambient temperature is within the specified operating range of 0 °C to +50 °C.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7612-0AB12-0BG0?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices used in industrial environments.
What display size and resolution does this Panel PC have?
The 6AV7612-0AB12-0BG0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 256,000 colors.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC and WinCC flexible Runtime software, making it suitable for SCADA and HMI visualization applications.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AB12-0BG0 is rated IP65, providing protection against dust ingress and low-pressure water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces, enabling connectivity to PLCs, network infrastructure, and peripheral devices.
Troubleshooting
Panel PC does not power on after connecting 24 V DC supply
Measure the supply voltage at the power input connector to confirm it is within the 24 V DC tolerance range. Check the internal fuse and power supply board for damage.
Ensure the power supply provides a stable 24 V DC. Replace the internal fuse if blown. If the power supply board is faulty, replace or repair the internal power supply module.
Display remains blank or shows no image after power on
Verify that the unit completes its boot sequence by listening for hard disk activity. Check the display backlight by shining an external light source on the screen to detect a faint image.
If the backlight has failed, replace the CCFL backlight lamp or the inverter board. If the display panel itself is faulty, replace the TFT display assembly. If the system boots but no image appears, check display cable connections internally.
Touch screen input is unresponsive or inaccurate
Check whether the touch controller is recognized in the Windows Device Manager. Inspect the touch screen surface for physical damage or contamination.
Clean the touch screen surface with a soft, dry cloth. Run the touch screen calibration utility from the Control Panel. If the touch controller is not recognized, reinstall the touch screen driver or replace the touch screen overlay.
Ethernet communication is lost or intermittent
Check the Ethernet cable and connector for physical damage. Verify the network configuration (IP address, subnet mask, gateway) in the Windows network settings. Test connectivity using the ping command.
Replace the Ethernet cable if damaged. Reconfigure the network settings to match the plant network. If the onboard Ethernet port is faulty, replace the network interface card or the mainboard.
System freezes or restarts unexpectedly during operation
Check the system event log in Windows for error entries. Monitor the CPU temperature and fan operation. Inspect the CompactFlash card or hard disk for errors using disk diagnostic tools.
Clean the ventilation slots and replace the cooling fan if defective. Run chkdsk to repair file system errors on the storage medium. If the issue persists, restore the operating system from a known-good backup image.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page



