• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB10-0AH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AB10-0AH0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB10-0AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB10-0AH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a flat-panel display with an integrated PC platform, providing a compact and robust solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7612-0AB10-0AH0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen interface. It is powered by an Intel Celeron processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides standard industrial interfaces including USB, serial (COM), and Ethernet ports, and is designed for front-panel mounting with an IP65-rated front bezel for protection against dust and water ingress.

    The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, chemical, and food and beverage industries for supervisory control and data acquisition (SCADA), process visualization, and machine-level HMI applications. Its fanless or low-maintenance design options make it suitable for environments where reliability and long service intervals are critical. The integrated PC architecture allows it to run third-party software alongside Siemens automation solutions, making it a flexible platform for complex visualization and data logging tasks.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT Color LCD
    Display Colors 262,144 colors
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Power Consumption Approx. 60 W
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting (front flush)
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM)
    Certifications CE, UL
    Series SIMATIC Panel PC 670

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup error or boot failure detected during POST.
    Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty.
    Event ID: 1000
    Application fault — the HMI runtime software (e.g. WinCC flexible) has crashed or terminated unexpectedly.
    Restart the runtime application. Check application project for configuration errors. Reinstall the runtime software if the issue persists.
    Event ID: 10000
    Communication loss between the Panel PC and the connected PLC or controller.
    Check Ethernet or serial cable connections. Verify IP address configuration and PLC communication settings. Restart both devices if necessary.
    Event ID: 26
    System time synchronization error — the real-time clock has lost its time setting.
    Replace the internal CMOS battery (CR2032 or equivalent). Reconfigure the system time and date after battery replacement.
    Hardware Watchdog Timeout
    The system watchdog has triggered due to an OS or application hang, causing an automatic reset.
    Investigate running processes for software loops or memory leaks. Ensure the WinCC runtime and OS are up to date with the latest patches.
    Temperature Warning
    Internal temperature sensor has detected an over-temperature condition.
    Check ambient temperature against specifications. Clean ventilation slots and ensure adequate airflow around the panel. Verify cooling fan operation if applicable.
    Storage Media Error
    Read/write error detected on the CompactFlash card or hard disk drive.
    Back up project data immediately. Run a disk check utility. Replace the CompactFlash card or HDD if errors persist.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 (6AV7612-0AB10-0AH0) support?

    The SIMATIC Panel PC 670 supports Microsoft Windows XP Professional and Windows XP Embedded, which are pre-installed depending on the variant. It is compatible with SIMATIC WinCC and WinCC flexible runtime software.

    What is the supply voltage for the 6AV7612-0AB10-0AH0?

    This Panel PC operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 series devices.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AB10-0AH0 carries an IP65 protection rating, making it resistant to dust and low-pressure water jets. The rear of the unit is rated IP20.

    Can the SIMATIC Panel PC 670 run third-party software?

    Yes, because it is a full PC-based platform running Windows, it can run third-party HMI, SCADA, and data logging software in addition to Siemens WinCC applications.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), USB ports, and RS-232 serial (COM) interfaces for connectivity to PLCs, peripherals, and networks.

    Troubleshooting

    Display remains blank after power is applied

    Measure 24 V DC at the power supply connector. Check the internal fuse and verify the power supply unit output. Observe whether the power LED illuminates.

    Replace the internal fuse if blown. If the power supply is faulty, replace the Panel PC power supply module. If the display backlight has failed, the CCFL backlight or inverter board may need replacement.

    Touchscreen does not respond or registers incorrect touch positions

    Check whether the touch controller is recognized in Windows Device Manager. Verify that the resistive touch surface is clean and undamaged. Run the touch calibration utility.

    Recalibrate the touchscreen using the Windows control panel or Siemens calibration tool. If calibration fails, update or reinstall the touch driver. Replace the touch panel overlay if the surface is physically damaged.

    Panel PC fails to boot and displays a BIOS error or stops at POST

    Check the CompactFlash card or hard disk connection and integrity. Listen for POST beep codes and note any error messages on screen. Verify BIOS settings are correct.

    Reseat the CompactFlash card or HDD. Restore BIOS defaults if settings are corrupted. Replace the storage media and reinstall the operating system and WinCC runtime if the drive has failed.

    Communication with PLC is lost intermittently or permanently

    Check Ethernet cable and switch/hub connections. Verify the IP address configuration in Windows and in the WinCC project. Use ping to test network connectivity to the PLC.

    Replace faulty Ethernet cables or connectors. Correct IP address conflicts or subnet mismatches. Update the communication driver or WinCC project connection settings as needed.

    System clock resets to incorrect date and time after power cycle

    This typically indicates a depleted CMOS battery on the motherboard. Access the unit and locate the CMOS battery (typically a CR2032 coin cell).

    Replace the CMOS battery with a new CR2032 cell. After replacement, re-enter the correct date, time, and BIOS settings, then verify the clock retains the correct time after a power cycle.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart