Siemens 6AV7612-0AB10-0AJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB10-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AB10-0AJ0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an industrial-grade processor and runs Microsoft Windows-based operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB, serial (RS-232), and Ethernet ports for connectivity to PLCs and higher-level systems. It is designed for panel mounting and meets industrial EMC and safety standards including CE certification.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process industries, and machine building where a combined PC and HMI platform is required. It is suitable for applications such as SCADA visualization, data logging, recipe management, and supervisory control in industries including automotive, food and beverage, chemical processing, and packaging. Its panel-mount design and industrial-grade construction make it appropriate for integration into control cabinets and operator stations on the factory floor.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes and System Events
- Event ID: 100000
- System startup error — the operating system failed to boot correctly or a critical system file is missing.
Check the hard disk or CompactFlash card for errors. Reinstall or restore the operating system image if necessary. - Event ID: 110000
- Hardware watchdog timeout — the watchdog timer was not reset within the defined interval, indicating a system hang.
Check CPU load and running processes. Restart the Panel PC and investigate any software causing excessive CPU usage. - Event ID: 120000
- Fan failure detected — the internal cooling fan has stopped or is running below the minimum speed threshold.
Check and clean the fan. Replace the fan unit if it is defective to prevent thermal shutdown. - Event ID: 130000
- Temperature warning — the internal temperature has exceeded the warning threshold.
Check ambient temperature and ventilation around the panel. Clean air filters and ensure the cooling fan is operational. - Event ID: 140000
- Battery low warning — the CMOS/BIOS backup battery voltage is below the minimum level.
Replace the internal CMOS backup battery (typically CR2032 or equivalent) to prevent loss of BIOS settings. - Event ID: 150000
- Storage medium error — read/write errors detected on the hard disk or CompactFlash storage device.
Run a disk check utility. Replace the hard disk or CompactFlash card if errors persist and restore the system image. - Event ID: 160000
- Communication interface fault — loss of communication on the Ethernet or serial interface.
Check cable connections, network settings, and interface configuration. Verify IP address settings and replace cables if damaged.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7612-0AB10-0AJ0) support?
The SIMATIC Panel PC 670 supports Microsoft Windows XP Professional and Windows XP Embedded, and is compatible with SIMATIC WinCC and other Siemens HMI software packages.
What is the display size and resolution of this Panel PC?
The 6AV7612-0AB10-0AJ0 features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen input.
What is the supply voltage for the 6AV7612-0AB10-0AJ0?
This Panel PC operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices.
Is this Panel PC compatible with Siemens SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and other PC-based HMI and SCADA software from Siemens.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AB10-0AJ0 is rated IP65, providing protection against dust ingress and low-pressure water jets.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the internal fuse and inspect the backlight inverter board for visible damage.
Restore correct supply voltage if out of range. Replace the backlight inverter or CCFL backlight lamp if the display remains dark with the system otherwise operational.
Touch screen does not respond or is inaccurate
Check if the touch screen driver is correctly installed in the operating system. Inspect the touch screen connector cable for secure seating.
Recalibrate the touch screen using the Windows calibration utility. If calibration fails, replace the touch screen overlay or the touch controller board.
Panel PC fails to boot or continuously restarts
Check the hard disk or CompactFlash storage for errors using a diagnostic utility. Inspect BIOS settings for correct boot device selection.
Restore or reinstall the operating system image from a backup. Replace the storage medium if hardware errors are detected.
Loss of communication with PLC via Ethernet
Verify the Ethernet cable connection and check the IP address configuration in the operating system network settings. Test the network port with a known-good cable.
Correct the IP address and subnet mask settings. Replace the Ethernet cable if damaged. If the port is faulty, use a USB-to-Ethernet adapter or replace the mainboard.
BIOS settings lost after power off
The CMOS backup battery is likely discharged. Observe whether the system clock resets to a default date/time on each power cycle.
Replace the internal CMOS backup battery with the correct type as specified in the service manual to retain BIOS and clock settings.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page