Siemens 6AV7612-0AB10-0AE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB10-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and rugged solution for process visualization and machine control.
The SIMATIC Panel PC 670 (6AV7612-0AB10-0AE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touch-sensitive screen for operator interaction. It is equipped with an x86-compatible processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard industrial communication interfaces including Ethernet (RJ45) and serial ports, and supports expansion via PCI slots. It is built to withstand industrial environments with a front panel protection rating of IP65.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a full PC-based HMI platform is required. Its compatibility with standard Windows software and Siemens SIMATIC software makes it suitable for complex visualization tasks, data logging, and integration with SIMATIC S7 PLCs via PROFIBUS or Ethernet. It is commonly found in automotive production lines, chemical processing plants, and packaging machinery.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Protection Rating (Front) | IP65 |
| Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, RS-422/485 |
| Mounting | Panel mounting |
| Operating System | Windows XP / Windows 2000 |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk integrity and connections. Verify BIOS settings. Attempt system restore or OS reinstallation if disk is functional. - Event ID: 200
- Hardware watchdog timeout — the system did not respond within the watchdog monitoring period.
Check CPU load and running processes. Ensure WinCC or HMI application is not hanging. Reconfigure watchdog timeout interval if necessary. - Event ID: 300
- Fan failure or thermal warning — internal cooling fan has stopped or temperature threshold exceeded.
Inspect and clean the cooling fan. Replace the fan if defective. Ensure ambient temperature is within specification and ventilation is adequate. - Event ID: 400
- Battery low warning — the CMOS/RTC backup battery voltage is below the minimum threshold.
Replace the internal CMOS battery (typically CR2032 or equivalent). After replacement, re-enter BIOS settings and verify system time and date. - Event ID: 500
- Ethernet communication failure — network interface not detected or link is down.
Check Ethernet cable and switch/hub connection. Verify network adapter settings in Device Manager. Reinstall network drivers if the adapter is not recognized. - Event ID: 600
- Hard disk error or disk read/write failure detected.
Run disk diagnostics utility. Check disk connections and power supply to the drive. Replace hard disk if errors persist and restore system image. - Event ID: 700
- Application software (WinCC/HMI) runtime error or unexpected termination.
Check Windows Event Viewer for application error details. Reinstall or repair the HMI runtime software. Verify software license dongle is present and valid.
Frequently Asked Questions
What operating systems are supported by the 6AV7612-0AB10-0AE0?
The SIMATIC Panel PC 670 (6AV7612-0AB10-0AE0) supports Microsoft Windows 2000 and Windows XP. It is compatible with SIMATIC WinCC and other standard Windows-based HMI and SCADA applications.
What is the display size and resolution of this Panel PC?
This unit features a 12-inch TFT color LCD display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen for operator input.
What communication interfaces are available on this unit?
The 6AV7612-0AB10-0AE0 provides Ethernet (RJ45), RS-232, and RS-422/485 serial interfaces, enabling connectivity to SIMATIC S7 PLCs via Industrial Ethernet or MPI/PROFIBUS adapters.
What is the front panel protection rating of this Panel PC?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.
Can this Panel PC be used with SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with SIMATIC WinCC visualization software, as well as other Siemens HMI software packages running on Windows 2000 or Windows XP.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power input connector. Verify the internal fuse and backlight inverter board. Measure backlight voltage output.
Replace the backlight inverter or CCFL backlight lamp if the display panel itself is functional. If no power is detected, check the internal power supply module and input wiring.
Touchscreen does not respond or registers incorrect touch positions
Check touchscreen controller calibration in the Windows control panel. Inspect the touchscreen ribbon cable connection to the controller board.
Recalibrate the touchscreen using the Siemens touchscreen calibration utility. If calibration fails, replace the touchscreen controller board or the resistive touch overlay.
System fails to boot and displays a disk error message
Attempt to boot from an external USB or CD-ROM drive. Run disk diagnostics to check for bad sectors or mechanical failure of the internal hard disk.
Replace the internal hard disk with a compatible unit and restore the system image from a backup. Use a solid-state disk (SSD) replacement for improved reliability.
Ethernet communication to PLC is lost intermittently
Check the Ethernet cable and RJ45 connector for damage. Verify network adapter settings and IP configuration in Windows Device Manager and Network Settings.
Replace the Ethernet cable and ensure the switch port is functioning. Update or reinstall the network adapter driver. Check for IP address conflicts on the network.
System clock resets to incorrect date and time after power cycle
This indicates a depleted CMOS backup battery. Access the BIOS on startup to confirm the date and time are not retained between power cycles.
Replace the internal CMOS battery (typically a CR2032 lithium coin cell). After replacement, re-enter the correct date, time, and BIOS settings and save.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page