• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB10-0AF0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AB10-0AF0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB10-0AF0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB10-0AF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface applications, combining computing power with a robust flat-panel display in a single integrated unit. This unit is part of Siemens' SIMATIC HMI product line, intended for use as a high-performance operator station in industrial automation environments.

    The SIMATIC Panel PC 670 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), providing clear visualization of process data and operator interfaces. The unit is built around an industrial-grade processor platform and supports standard PC interfaces including USB, serial (RS-232), and parallel ports, as well as Ethernet connectivity for integration into plant networks. It runs Microsoft Windows operating systems and supports SIMATIC WinCC and other SCADA/HMI software packages. The front panel is rated to IP65, protecting against dust and water ingress in harsh industrial environments.

    The SIMATIC Panel PC 670 is widely deployed in manufacturing, process industries, and machine automation where a full PC-based HMI solution is required. It is suitable for applications such as SCADA visualization stations, recipe management, data logging, and complex operator interfaces that exceed the capabilities of standard operator panels. Industries including automotive, food and beverage, chemical processing, and discrete manufacturing commonly use this platform due to its combination of industrial robustness and standard PC flexibility.

    Technical Specifications

    Display Size 12.1 inch
    Display Type TFT color LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Front Panel Protection IP65
    Operating Voltage 24 V DC
    Communication Interface Ethernet (RJ45), RS-232, USB, Parallel
    Operating System Windows XP / Windows 2000 (factory configurable)
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 95 % (non-condensing)
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Touch Technology Resistive touchscreen

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly, possibly due to a corrupted system partition or failed storage device.
    Check the hard disk or CompactFlash card for errors. Attempt a system restore or reinstall the operating system image using the Siemens recovery medium.
    Event ID: 101
    Hardware watchdog timeout — the watchdog timer was not serviced in time, indicating a system hang or software freeze.
    Restart the Panel PC. If the issue persists, check for software conflicts or excessive CPU load. Update or reinstall the HMI application software.
    Event ID: 200
    Fan failure detected — the internal cooling fan has stopped or is running below the required speed threshold.
    Inspect and clean the fan. Replace the fan unit if it is mechanically failed. Ensure ventilation clearances around the panel are maintained.
    Event ID: 201
    Overtemperature warning — the internal temperature has exceeded the permitted operating threshold.
    Check ambient temperature and ensure it is within the 0–45 °C operating range. Clean air filters and verify fan operation. Reduce heat load if possible.
    Event ID: 300
    Ethernet communication error — loss of network connection or failure to establish communication with the PLC or SCADA server.
    Check Ethernet cable and switch connections. Verify IP address configuration. Check for network conflicts and ensure the PLC or server is reachable via ping.
    Event ID: 400
    WinCC runtime error — the SIMATIC WinCC HMI application has encountered a runtime fault and terminated unexpectedly.
    Review the WinCC diagnostic log for the specific error. Reinstall or repair the WinCC runtime installation. Ensure the project configuration is compatible with the installed WinCC version.
    Event ID: 500
    Storage device error — read/write error on the hard disk or CompactFlash card used for the operating system or data storage.
    Run a disk check utility (chkdsk). Replace the storage medium if physical errors are detected. Restore the system image from backup.
    Event ID: 600
    Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
    Measure the supply voltage at the power connector. Ensure the supply is within the specified 24 V DC range. Check wiring, connectors, and the external power supply unit for faults.

    Frequently Asked Questions

    What display size and resolution does the 6AV7612-0AB10-0AF0 have?

    This Panel PC features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).

    What is the supply voltage for the SIMATIC Panel PC 670?

    The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC industrial panel PCs.

    What HMI software is compatible with this Panel PC?

    The SIMATIC Panel PC 670 is compatible with SIMATIC WinCC, WinCC flexible, and other standard PC-based SCADA and HMI software packages that run on Windows.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AB10-0AF0 is rated to IP65, providing protection against dust and directed water jets.

    Can this Panel PC communicate with Siemens S7 PLCs?

    Yes, via its Ethernet interface and optional PROFIBUS or MPI communication cards, the Panel PC 670 can communicate directly with Siemens S7-300 and S7-400 PLCs using standard SIMATIC protocols.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the internal fuse is intact. Attempt to determine whether the PC is booting by listening for hard disk activity.

    Restore the supply voltage to within the 24 V DC specification. Replace a blown internal fuse if found. If the display backlight has failed, the backlight inverter or display assembly may need replacement.

    Touchscreen does not respond to touch input

    Check whether the touchscreen driver is loaded correctly in the Windows Device Manager. Verify that the resistive touch surface is not physically damaged or contaminated.

    Recalibrate the touchscreen using the Siemens calibration utility in the Windows control panel. If the driver is missing or corrupted, reinstall the touchscreen driver from the Siemens recovery image. Replace the touch overlay if physically damaged.

    Panel PC fails to boot into Windows and displays a boot error

    The operating system partition on the hard disk or CompactFlash card may be corrupted. Check BIOS boot order settings and verify the storage device is detected.

    Use the Siemens factory recovery medium to restore the operating system image. If the storage device is not detected, replace the hard disk or CompactFlash card and reinstall the OS image.

    Ethernet communication to PLC is lost intermittently

    Inspect the Ethernet cable and RJ45 connector for damage or loose connection. Check the network switch port status. Verify the IP address configuration has not changed.

    Replace the Ethernet cable if damaged. Assign a static IP address to avoid DHCP-related conflicts. Update the network adapter driver if available, and check for electromagnetic interference sources near the cable routing.

    Unit shuts down unexpectedly during operation

    Check the internal temperature via the BIOS or system monitoring utility. Verify that the cooling fan is operating. Measure the 24 V DC supply for voltage dips under load.

    Clean the air vents and fan. Ensure ambient temperature is within the 0–45 °C operating range. Stabilize the power supply. If the fan has failed, replace it to restore adequate cooling.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart