Siemens 6AV7612-0AA30-0BE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA30-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a built-in computing platform, offering a compact all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 65,536 colors. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, providing a familiar environment for SCADA and HMI software deployment. The unit offers multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), and supports expansion via PCI slots. It is built to withstand industrial environments with a front panel protection rating of IP65.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, automotive production, and machine building applications where a robust, integrated PC-based HMI solution is required. Its compatibility with Siemens WinCC and other SCADA software packages makes it suitable for complex visualization tasks. The fanless or low-noise design options and industrial-grade components ensure reliable long-term operation in continuous production environments.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 65,536 colors |
| Display Type | TFT LCD |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Front Panel Protection | IP65 |
| Rear Protection | IP20 |
| Communication Interfaces | Ethernet (RJ45), USB, RS-232, RS-422/RS-485 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup failure or BIOS initialization error during boot sequence.
Check power supply voltage at 24 V DC input. Verify BIOS settings and reset to defaults if necessary. Reseat RAM modules and check for loose internal connections. - Event ID: 101
- Operating system boot failure or corrupted system partition detected.
Boot from recovery media and restore the OS image. Check the CompactFlash card or hard disk for errors using diagnostic tools. - Event ID: 200
- Ethernet communication link failure or network interface not detected.
Check Ethernet cable and switch port. Verify network adapter settings in Device Manager. Replace Ethernet cable or check RJ45 connector for damage. - Event ID: 300
- USB device not recognized or USB interface fault.
Reconnect the USB device. Try an alternate USB port. Check USB driver installation in the operating system. Inspect USB connectors for physical damage. - Event ID: 400
- Touchscreen calibration error or touch input not responding.
Recalibrate the touchscreen using the Siemens calibration utility in the control panel. If calibration fails, check the touch controller connection internally and replace the touch overlay if defective. - Event ID: 500
- Fan failure or thermal overtemperature warning detected by system monitoring.
Check that ventilation slots are not blocked. Verify ambient temperature is within specification. Inspect and replace the cooling fan if it has failed. Clean dust filters if present. - Event ID: 600
- Hard disk or storage medium error detected during operation.
Run disk diagnostics to check for bad sectors. Back up data immediately. Replace the hard disk or CompactFlash card as required and restore the system image. - Event ID: 700
- PCI expansion card or internal hardware not recognized at startup.
Reseat the PCI expansion card. Verify card compatibility with the Panel PC 670 platform. Update or reinstall drivers. Replace the expansion card if the fault persists.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7612-0AA30-0BE0) support?
The SIMATIC Panel PC 670 supports Microsoft Windows XP Professional and Windows 2000 Professional, which are pre-installed or available as factory options. It is compatible with Siemens WinCC and other Windows-based HMI and SCADA software.
What is the supply voltage for this Panel PC?
The 6AV7612-0AA30-0BE0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs in this series.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for panel-mounted industrial installations.
Is the 6AV7612-0AA30-0BE0 compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens WinCC visualization software, as well as other Windows-based SCADA and HMI applications.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), multiple USB ports, and serial interfaces (RS-232 and RS-422/RS-485), enabling connectivity to PLCs, field devices, and plant networks.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the input connector. Verify the internal fuse is intact. Confirm the display brightness setting has not been set to minimum via software.
Restore the 24 V DC supply to within specification. Replace the internal fuse if blown. Adjust display brightness settings in the operating system or BIOS. If the backlight has failed, replace the inverter board or display assembly.
Touchscreen does not respond or registers incorrect touch positions
Determine whether the issue is a calibration problem or a hardware fault by attempting recalibration. Check for physical damage to the touch overlay.
Recalibrate the touchscreen using the Siemens calibration utility. If calibration does not resolve the issue, inspect the internal touch controller cable connections and replace the touch overlay if damaged.
Panel PC fails to boot into the operating system
Observe the boot sequence for BIOS error messages. Check the storage medium (hard disk or CompactFlash card) for errors using diagnostic tools booted from external media.
Restore the OS image from a Siemens recovery disk or backup image. Replace the hard disk or CompactFlash card if it is found to be defective. Ensure BIOS settings are correctly configured for the installed storage device.
Ethernet communication is not established
Check the Ethernet cable connection and verify the link LED on the RJ45 port is active. Inspect network adapter settings in Device Manager for driver errors or disabled interfaces.
Replace the Ethernet cable and verify switch port operation. Reinstall or update the network adapter driver. If the onboard Ethernet controller is faulty, install a compatible PCI Ethernet expansion card as a replacement.
System overheats and shuts down unexpectedly
Check ambient temperature around the panel PC and verify that ventilation openings are not obstructed. Inspect the cooling fan operation and check for dust accumulation on vents and heat sinks.
Ensure the installation environment is within the specified operating temperature range of 0 to 45 degrees C. Clear any obstructions from ventilation slots. Clean dust from internal components. Replace the cooling fan if it is not operating correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page