Siemens 6AV7612-0AA30-0BF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA30-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates computing power and a display into a single compact panel-mount device, offering a robust platform for SCADA, process visualization, and machine control applications.
The SIMATIC Panel PC 670 (6AV7612-0AA30-0BF0) features a 15-inch TFT display with a resolution of 1024 x 768 pixels and 65,536 colors, providing clear visualization of process data. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP or Windows 2000, supporting standard PC software environments. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), enabling integration with a wide range of automation and IT systems. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in the automotive, chemical, food and beverage, and manufacturing industries for machine-level and plant-level visualization. Its fanless or low-maintenance design options and industrial-grade construction make it suitable for continuous operation in harsh factory environments. The device is commonly deployed as an operator station in process control systems, production lines, and test bench applications where reliable, long-term PC-based HMI operation is required.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels |
| Display Colors | 65,536 colors |
| Display Type | TFT LCD |
| Processor | Intel Celeron |
| Operating System | Microsoft Windows XP / Windows 2000 |
| Input/Operating Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (serial) |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the CompactFlash card or hard disk for errors. Reinstall or restore the operating system image if corrupted. - Event ID: 200
- Hardware watchdog timeout — the system did not respond within the watchdog monitoring period.
Check CPU load and running processes. Reduce system load or adjust watchdog timeout settings in the BIOS/system configuration. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or automation system.
Verify Ethernet or serial cable connections. Check IP address configuration and ensure the PLC communication driver is running correctly. - Temperature Warning
- Internal system temperature has exceeded the recommended operating threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean any blocked air vents and verify cooling components are functional. - Drive Read/Write Error
- Error accessing the CompactFlash card or hard disk drive during operation or startup.
Replace the CompactFlash card or hard disk. Restore the system image from a backup and verify drive integrity before restarting. - Display Backlight Failure
- The TFT display backlight has failed or is not illuminating, resulting in a dark or dim screen.
Replace the backlight inverter board or the TFT display assembly. Check the backlight power connector for secure contact. - Power Supply Fault
- The 24 V DC supply voltage is out of tolerance or has been interrupted.
Measure the supply voltage at the power input connector. Ensure the supply is within the specified 24 V DC range and check wiring and fusing.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AA30-0BF0?
The SIMATIC Panel PC 670 (6AV7612-0AA30-0BF0) operates on a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range for reliable operation.
What is the IP protection rating of this Panel PC?
The front panel of the 6AV7612-0AA30-0BF0 is rated IP65, providing protection against dust and low-pressure water jets. The rear of the unit does not carry the same IP65 rating.
What communication interfaces are available on this unit?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces, allowing connection to PLCs, automation networks, and peripheral devices.
Which operating systems are supported by the SIMATIC Panel PC 670?
The 6AV7612-0AA30-0BF0 supports Microsoft Windows XP and Windows 2000, enabling the use of standard PC-based HMI and SCADA software packages.
Can the storage medium be replaced or upgraded on this Panel PC?
Yes, the SIMATIC Panel PC 670 typically uses a CompactFlash card or hard disk as its storage medium, which can be replaced. Siemens provides system restore images for re-imaging the storage device after replacement.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power input connector. Verify the backlight inverter is receiving power and inspect the display cable connections internally.
Replace the backlight inverter or TFT display assembly if the backlight has failed. If no supply voltage is present, check external fusing and the power supply unit.
Panel PC does not boot or gets stuck during startup
Attempt to boot from an external medium to determine if the issue is with the internal storage. Check the CompactFlash card or hard disk for physical damage or corruption.
Replace the CompactFlash card or hard disk and restore the operating system image using the Siemens recovery image. Reseat all internal connectors and memory modules.
Touchscreen does not respond or is inaccurate
Check if the touchscreen controller is recognized in the operating system device manager. Verify the touchscreen calibration settings within the Windows control panel.
Recalibrate the touchscreen using the Siemens or Windows touchscreen calibration utility. If unresponsive, replace the touchscreen overlay or the touchscreen controller board.
Loss of communication with PLC or SCADA system
Ping the Panel PC from the network to verify Ethernet connectivity. Check the IP address configuration, subnet mask, and gateway settings in Windows network settings.
Correct any IP address conflicts or misconfiguration. Replace the Ethernet cable or switch port if physical connectivity is faulty. Reinstall the communication driver if the network adapter is not recognized.
System runs slowly or freezes during operation
Monitor CPU and memory usage in Windows Task Manager. Check for excessive background processes, antivirus activity, or a nearly full storage medium.
Remove unnecessary startup programs and background processes. Free up storage space on the CompactFlash card or hard disk. If hardware degradation is suspected, replace the storage medium and restore a clean system image.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page