• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AA10-0CG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AA10-0CG0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AA10-0CG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AA10-0CG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling complex SCADA, process visualization, and machine control applications.

    The SIMATIC Panel PC 670 6AV7612-0AA10-0CG0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), providing clear visualization of process data. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, supporting Siemens WinCC and other SCADA software packages. The unit includes standard PC interfaces such as USB, serial (RS-232), parallel, and Ethernet ports, enabling integration with a wide range of industrial peripherals and network infrastructure. The front panel is designed to IP65 protection rating, making it resistant to dust and water ingress from the front.

    The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, chemical, and manufacturing industries for machine-level visualization and process control. Its panel-mount design allows direct integration into control cabinet doors or operator stations, reducing installation footprint. The combination of standard PC hardware with industrial-grade construction makes it suitable for applications requiring both high computational performance and reliable continuous operation in harsh industrial environments.

    Technical Specifications

    Display Size 12.1 inch
    Display Type TFT Color LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 256,000 colors
    Input/Operating Voltage 24 V DC
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Communication Interface Ethernet (RJ45), RS-232 (COM), Parallel (LPT), USB
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Mounting Panel mount
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly, possibly due to a corrupted system partition or failed storage device.
    Check the hard disk or CompactFlash card for errors. Restore or reinstall the operating system image using the recovery partition or Siemens restore media.
    Event ID: 1000
    Application fault — a software application such as WinCC Runtime has crashed unexpectedly.
    Review the Windows Event Viewer for application error details. Reinstall or update the affected software. Check for memory or hardware conflicts.
    Event ID: 7000
    Service failed to start — a required Windows service did not start during boot, which may affect HMI functionality.
    Check the Windows Event Viewer under System logs. Ensure all required services are set to automatic startup. Reinstall the HMI software if the service is corrupted.
    BIOS POST Error
    Power-On Self-Test failure detected during startup, indicating a hardware fault such as failed RAM or missing boot device.
    Reseat RAM modules and check all internal connections. Verify the boot device (HDD or CF card) is detected in BIOS. Replace faulty hardware components as indicated by the POST beep code.
    WinCC Runtime Error
    WinCC Runtime cannot establish a connection to the configured PLC or data source.
    Verify Ethernet or MPI/PROFIBUS connection between the Panel PC and the PLC. Check the WinCC project communication settings and ensure the PLC is in RUN mode.
    Watchdog Timeout
    The hardware watchdog timer has triggered a system reset due to the operating system or application becoming unresponsive.
    Investigate CPU load and running processes. Optimize or reduce the number of concurrent applications. Check for software loops or memory leaks in the HMI application.
    Temperature Warning
    Internal system temperature has exceeded the recommended operating threshold, triggering a thermal warning.
    Check that ventilation slots are unobstructed. Verify ambient temperature is within the 0–45 °C operating range. Clean any dust from ventilation areas and check fan operation if applicable.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 6AV7612-0AA10-0CG0 run?

    This unit is designed to run Windows XP Professional or Windows 2000, depending on the factory configuration. It supports Siemens WinCC and other compatible SCADA and HMI software packages.

    What is the supply voltage for this Panel PC?

    The 6AV7612-0AA10-0CG0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.

    What is the front panel protection rating of this unit?

    The front panel of the SIMATIC Panel PC 670 is rated to IP65, providing full protection against dust and resistance to water jets, making it suitable for installation in industrial environments.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), RS-232 serial (COM), parallel (LPT), and USB ports, enabling connectivity to PLCs, printers, and other industrial peripherals.

    Is this Panel PC compatible with Siemens S7 PLCs?

    Yes, the SIMATIC Panel PC 670 can communicate with Siemens S7-300 and S7-400 PLCs via Ethernet or through optional PROFIBUS/MPI interface cards, using WinCC or Step 7 software.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector. Verify the internal fuse is intact. Determine whether the PC is booting (listen for HDD activity) but only the display is not illuminating.

    Replace the backlight inverter board or the TFT display panel if the PC is booting but no image appears. If there is no power at all, check the 24 V DC supply and replace the internal power supply board if faulty.

    Panel PC fails to boot into Windows and shows a missing operating system error

    The hard disk drive or CompactFlash storage card may have failed or the system partition may be corrupted. Enter BIOS to verify the boot device is detected.

    Restore the operating system using the Siemens recovery partition or a factory restore image. If the storage device is not detected, replace the HDD or CompactFlash card with a compatible unit and reinstall the OS.

    Touchscreen does not respond to input or is misaligned

    Check whether the touchscreen controller driver is loaded correctly in Windows Device Manager. Determine if the issue is a calibration problem or a hardware failure by testing with a mouse.

    Recalibrate the touchscreen using the Siemens or Windows touchscreen calibration utility. If the touchscreen remains unresponsive after recalibration, replace the touchscreen overlay or the touchscreen controller board.

    Ethernet communication to PLC is intermittent or fails

    Check the Ethernet cable and RJ45 connector for physical damage. Verify the IP address configuration in Windows matches the network settings of the connected PLC. Check the WinCC communication channel configuration.

    Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network. Update the network adapter driver or replace the Ethernet adapter if the hardware is faulty.

    System runs slowly or HMI application freezes during operation

    Monitor CPU and RAM usage in Windows Task Manager. Check for excessive background processes, low available disk space, or memory fragmentation caused by long-term continuous operation.

    Close unnecessary background applications and disable non-essential startup programs. Defragment the hard disk and ensure adequate free disk space. If RAM is insufficient, upgrade to the maximum supported capacity for this platform.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart