• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AA10-0CH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AA10-0CH0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AA10-0CH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AA10-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7612-0AA10-0CH0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors, providing clear visualization of process data. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting standard PC interfaces including USB, serial (RS-232), and parallel ports. The unit supports communication via Ethernet (RJ45) and can be expanded with PROFIBUS or MPI communication cards, making it compatible with Siemens SIMATIC S7 PLC families. The fanless or fan-cooled design options and robust aluminum front panel contribute to reliable operation in industrial conditions.

    The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, chemical processing, and food and beverage industries where a full PC-based HMI platform is required. It is suitable for applications demanding SCADA visualization, recipe management, data logging, and integration with Siemens WinCC or other SCADA software packages. The panel-mount form factor and IP65-rated front panel make it appropriate for direct installation into control cabinet doors and operator panels in harsh industrial environments.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Input/Operating Voltage 24 V DC
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet (RJ45), RS-232, USB, Parallel
    Mounting Panel mount
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating System Windows XP / Windows 2000

    Common Error Codes & System Events

    Event ID: 1000
    Application error — an application process has terminated unexpectedly.
    Check Windows Event Viewer for details. Reinstall or update the affected application (e.g., WinCC Runtime). Verify sufficient RAM and disk space.
    Event ID: 7026
    A boot-start or system-start driver failed to load.
    Check Device Manager for driver conflicts. Reinstall the relevant hardware driver or restore the system to a known-good configuration.
    Event ID: 6008
    Unexpected system shutdown — the previous system shutdown was unexpected.
    Check power supply stability at the 24 V DC input. Inspect for overheating. Review event logs for preceding errors.
    BIOS POST Error
    Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
    Reseat RAM modules and CompactFlash/hard disk. Verify all internal connectors are secure. Replace faulty hardware component if necessary.
    WinCC Runtime Error
    WinCC Runtime fails to start or crashes during operation.
    Verify WinCC license is valid and installed. Check available disk space and RAM. Reinstall WinCC Runtime if the issue persists.
    Network Communication Fault
    Loss of Ethernet communication between Panel PC and PLC or SCADA server.
    Check Ethernet cable and switch connections. Verify IP address configuration. Ping the target device and check firewall settings.
    Temperature Warning
    Internal temperature has exceeded the recommended operating threshold.
    Check ambient temperature and ensure adequate ventilation around the panel. Clean air filters if present. Verify the cooling fan is operational.
    Drive Read/Write Error
    Operating system reports errors reading from or writing to the storage device (CompactFlash or hard disk).
    Run a disk check utility (chkdsk). Back up data immediately. Replace the CompactFlash card or hard disk drive if errors persist.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AA10-0CH0?

    The SIMATIC Panel PC 670 (6AV7612-0AA10-0CH0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), RS-232 serial, USB, and parallel ports as standard interfaces. It can be expanded with optional PROFIBUS or MPI communication cards for direct PLC connectivity.

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and WinCC flexible SCADA and HMI software, as well as other standard Windows-based automation software packages.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7612-0AA10-0CH0 carries an IP65 protection rating, making it resistant to dust ingress and water jets, suitable for direct installation in control cabinet doors.

    What operating system does this Panel PC support?

    The 6AV7612-0AA10-0CH0 was supplied with Microsoft Windows XP Professional or Windows 2000, which are the supported operating systems for this hardware generation.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the input connector. Check whether the power LED is illuminated. Listen for hard disk or fan activity to determine if the PC is booting.

    If no supply voltage is present, check the external power supply and wiring. If voltage is present but display is blank, check the display cable connection internally or replace the backlight inverter. If the unit boots but no image appears, connect an external monitor via the VGA port to isolate a display fault.

    Panel PC boots but fails to load Windows

    Observe the boot sequence for error messages. Check whether the CompactFlash card or hard disk is detected in the BIOS. Run a disk check if possible.

    Reseat the CompactFlash card or hard disk drive. If the storage device is not detected, replace it. Restore the operating system image from a backup or reinstall Windows using the Siemens recovery media.

    Touchscreen does not respond or is inaccurate

    Verify the touchscreen controller is recognized in Windows Device Manager. Check for physical damage to the touch surface. Attempt touchscreen recalibration via the control panel.

    Recalibrate the touchscreen using the Windows touchscreen calibration utility. If the touchscreen remains unresponsive, check the internal ribbon cable connection. Replace the touchscreen overlay if the controller is functioning but calibration fails.

    Loss of communication with SIMATIC S7 PLC

    Check the Ethernet or PROFIBUS cable connections. Verify the IP address or PROFIBUS station address configuration in the communication software. Use diagnostic tools such as STEP 7 or TIA Portal to check the network.

    Replace or reseat the network cable. Verify correct IP addressing and subnet mask settings. Reinstall the communication driver or PROFIBUS card driver if the interface is not recognized in Device Manager.

    Unit shuts down unexpectedly or restarts randomly

    Check the 24 V DC supply for voltage drops or ripple using a multimeter or oscilloscope. Monitor internal temperature via BIOS or system monitoring software. Review the Windows Event Viewer for critical errors prior to shutdown.

    Stabilize the power supply and ensure adequate current capacity. Improve cabinet ventilation or reduce ambient temperature. If overheating is confirmed, clean any air filters and verify the cooling fan is operational. Replace the internal power supply board if voltage instability is confirmed internally.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart