Siemens 6AV7611-0AF30-0BF0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF30-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-performance computing platform with a robust industrial enclosure, providing a reliable operator interface for complex process control applications.
The SIMATIC Panel PC 670 (6AV7611-0AF30-0BF0) features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and touch screen capability, enabling intuitive operator interaction. The unit is equipped with standard PC interfaces including USB ports, serial COM ports, and Ethernet connectivity, supporting integration with SIMATIC WinCC and other SCADA software platforms. It is designed to operate on a 24 V DC supply and is built to withstand industrial environmental conditions, with a fanless or low-noise cooling concept depending on configuration. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, automotive, chemical processing, and energy industries where a full PC-based HMI platform is required. It is suitable for applications demanding high graphical performance, data logging, and connectivity to multiple automation systems simultaneously. The unit's industrial-grade construction and compatibility with standard Windows operating systems make it a practical choice for complex visualization and supervisory control tasks.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM ports) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System Compatibility | Windows XP, Windows 2000 |
Common Error Codes and System Events
- Event ID: 1000
- Application error — a software application running on the Panel PC has encountered an unexpected fault and terminated.
Check Windows Event Viewer for detailed error logs. Reinstall or update the affected application. Verify software compatibility with the installed OS version. - Event ID: 6008
- Unexpected shutdown — the system was not shut down cleanly, indicating a possible power loss or system crash.
Check the 24 V DC power supply for stability and correct voltage level. Inspect power connectors and cabling. Review event logs for preceding errors. - BIOS POST Error
- Hardware fault detected during Power-On Self-Test, preventing normal boot sequence.
Reseat RAM modules and expansion cards. Check hard disk or CompactFlash connection. If persistent, replace the faulty hardware component identified in the POST message. - WinCC Runtime Error
- SIMATIC WinCC runtime software has encountered a configuration or communication error and cannot start or maintain operation.
Verify WinCC project configuration and licensing. Check communication settings and PLC connection parameters. Reinstall WinCC runtime if the project file is corrupted. - Hard Disk Failure Warning
- The internal hard disk drive is reporting SMART errors or has failed, risking data loss and system instability.
Back up all project data immediately. Replace the internal hard disk drive with a compatible unit. Restore the OS and application software from a backup image. - Ethernet Link Down
- The Ethernet interface has lost its network connection, interrupting communication with PLCs or SCADA servers.
Check Ethernet cable integrity and connector seating. Verify switch or hub port status. Confirm correct IP address configuration in the operating system network settings. - Touchscreen Not Responding
- The touch screen controller is not registering input, preventing operator interaction with the HMI interface.
Recalibrate the touch screen using the Windows control panel or SIMATIC touch calibration utility. Check the internal touch controller ribbon cable connection. Replace the touch screen assembly if calibration fails.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AF30-0BF0?
The SIMATIC Panel PC 670 (6AV7611-0AF30-0BF0) operates on a 24 V DC power supply.
What is the display size and resolution of this Panel PC?
The unit features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA).
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AF30-0BF0 meets IP65 protection, providing resistance against dust and water jets.
Is this Panel PC compatible with SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and other standard Windows-based SCADA and HMI software packages.
What communication interfaces are available on this unit?
The 6AV7611-0AF30-0BF0 provides Ethernet (RJ45), USB ports, and RS-232 serial COM ports for connectivity to automation networks and peripherals.
Troubleshooting
Panel PC does not power on after switching on the 24 V DC supply
Measure the 24 V DC voltage at the power input connector to confirm correct supply voltage. Check internal fuses if accessible.
Ensure the power supply unit is providing stable 24 V DC within the specified tolerance. Replace any blown internal fuses with the correct rating. If the internal power supply board is faulty, replace it with a compatible unit.
Display is blank but the system appears to be running (LEDs active, HDD activity present)
Check display brightness settings in the OS. Test the backlight by connecting an external monitor via the VGA port if available.
Adjust display brightness through the Windows display settings or BIOS. If the backlight has failed, replace the CCFL backlight or the complete display assembly.
Touch screen input is inaccurate or unresponsive
Attempt touch screen recalibration through the Windows control panel. Check for physical damage or contamination on the screen surface.
Clean the screen surface and recalibrate using the SIMATIC or Windows touch calibration tool. If the touch controller hardware is faulty, replace the touch screen assembly.
System freezes or reboots unexpectedly during operation
Check the 24 V DC supply for voltage drops or ripple under load. Review Windows Event Viewer for critical errors or hardware warnings. Monitor CPU and system temperature.
Stabilize the power supply and ensure adequate current capacity. Clean any dust from ventilation areas. If overheating is detected, check cooling fans or heat sink contact. Replace faulty RAM or hard disk if hardware errors are logged.
Ethernet communication to PLC or SCADA server is intermittent or lost
Verify Ethernet cable condition and connector seating at both the Panel PC and the network switch. Check IP address configuration and network settings in Windows.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network requirements. Update the Ethernet adapter driver if available, or replace the network interface card if the hardware port is defective.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page