Siemens 6AV7611-0AF12-0CJ0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF12-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC platform, offering the flexibility of a standard computing environment within a ruggedized industrial enclosure.
The SIMATIC Panel PC 670 (6AV7611-0AF12-0CJ0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch screen interface for operator interaction. It runs on a Windows-based operating system and is powered by an industrial-grade processor, providing sufficient computing performance for SCADA, visualization, and data acquisition applications. The unit supports standard PC interfaces including USB, serial (RS-232), and Ethernet (RJ45), enabling integration with a wide range of automation and IT systems. It is designed for front-panel mounting with an IP65-rated front face, protecting against dust and water ingress in industrial settings.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building industries where a full PC platform is required at the operator station. It is suitable for applications such as SCADA visualization, recipe management, data logging, and integration with Siemens SIMATIC WinCC or other HMI software packages. Its robust construction and industrial certifications make it appropriate for installation in control cabinets and operator panels in sectors including automotive, food and beverage, and chemical processing.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| IP Protection (Front) | IP65 |
| IP Protection (Rear) | IP20 |
| Communication Interface | Ethernet RJ45, RS-232 (COM), USB |
| Mounting | Front panel mounting |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly, possibly due to a corrupted system partition or failed storage device.
Check the CompactFlash card or hard disk for errors. Restore the system image from backup or replace the storage medium. - Event ID: 101
- Hardware watchdog timeout — the system watchdog detected that the application or OS became unresponsive within the monitoring interval.
Restart the Panel PC. Check for software processes consuming excessive CPU resources. Update or reinstall the HMI application. - Event ID: 200
- Touch screen calibration error — the touch input is misaligned or the touch controller is not responding correctly.
Perform a touch screen recalibration via the SIMATIC Panel PC configuration tool or Windows control panel. If the issue persists, check the touch controller connection internally. - Event ID: 300
- Ethernet communication failure — the network interface is not establishing a connection with the configured network or PLC.
Verify Ethernet cable integrity and switch port status. Check IP address configuration and ensure the target PLC or server is reachable on the network. - Event ID: 400
- Fan failure or thermal warning — the internal cooling fan has stopped or the CPU temperature has exceeded the warning threshold.
Inspect and clean the ventilation openings. Replace the internal cooling fan if it has failed. Ensure ambient temperature is within the specified operating range. - Event ID: 500
- Battery low warning — the CMOS backup battery voltage is below the minimum threshold, risking loss of BIOS settings and real-time clock data.
Replace the internal CMOS lithium battery. After replacement, reconfigure BIOS settings and synchronize the system clock. - Event ID: 600
- Storage medium error — read/write errors detected on the CompactFlash card or hard disk drive, which may cause application or OS instability.
Run a disk check utility to identify bad sectors. Back up data immediately and replace the storage medium if errors are confirmed.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AF12-0CJ0?
The SIMATIC Panel PC 670 (6AV7611-0AF12-0CJ0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What display size and resolution does this Panel PC have?
This unit features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA), suitable for detailed HMI visualization.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AF12-0CJ0 carries an IP65 protection rating, making it resistant to dust and low-pressure water jets.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC and other Windows-based HMI and SCADA software packages, as it runs a standard Windows operating system.
What communication interfaces are available on this unit?
The unit provides Ethernet (RJ45), RS-232 serial (COM port), and USB interfaces for connectivity to PLCs, networks, and peripheral devices.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is active. Measure voltage at the internal power supply output rails.
Ensure the 24 V DC supply is within tolerance. If the internal power supply has failed, replace the power supply module. If the display backlight has failed, replace the backlight inverter or the display assembly.
Touch screen does not respond or responds inaccurately
Determine whether the issue is a calibration problem or a hardware failure by attempting recalibration. Check Device Manager in Windows for touch controller errors.
Recalibrate the touch screen using the Windows control panel or SIMATIC configuration utility. If the touch controller is not detected, check the internal ribbon cable connection between the touch overlay and the controller board. Replace the touch overlay if damaged.
Panel PC fails to boot into Windows
Observe the boot sequence for error messages. Check whether the CompactFlash card or hard disk is detected in BIOS. Listen for unusual sounds from the storage device.
Restore the system image from a backup CompactFlash card or hard disk. If the storage medium has failed, replace it with a compatible unit and reinstall the operating system and HMI software.
Ethernet communication not working
Check the Ethernet port LED indicators for link activity. Ping the Panel PC from another device on the network. Verify IP address settings in Windows Network Connections.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network configuration. If the onboard NIC has failed, consider using a USB-to-Ethernet adapter as a temporary measure and arrange for board-level repair.
System clock loses time after power off
This typically indicates a depleted CMOS backup battery. Enter BIOS setup and check whether the date and time reset to default values after each power cycle.
Replace the internal CMOS lithium battery (typically a CR2032 type). After replacement, reconfigure the BIOS date, time, and any custom BIOS settings.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page