Siemens 6AV7611-0AF12-0CH0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF12-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in flat-panel display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside process control applications.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen interface. It is equipped with an Intel Celeron processor and supports standard PC interfaces including USB, PS/2, and serial COM ports, as well as an Ethernet interface for network connectivity. The unit is designed for panel mounting with an IP65 protection rating on the front face, making it suitable for use in environments where dust and water ingress are a concern. It operates on a 24 V DC supply and is built to withstand the vibration and temperature ranges typical of industrial settings.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a full PC-based HMI solution is required. Its compatibility with Siemens WinCC, ProTool/Pro, and other standard Windows software makes it suitable for complex visualization tasks, data logging, and recipe management. Industries such as automotive, food and beverage, chemical processing, and packaging machinery commonly deploy this panel PC for operator interface and supervisory control applications.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT LCD |
| Display Colors | 256,000 colors |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM), PS/2 |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to load correctly during boot.
Check the hard disk or CompactFlash card for errors. Reinstall or restore the OS image if necessary. - Event ID: 200
- Hardware watchdog timeout — the system did not respond within the watchdog monitoring period.
Check CPU load and running processes. Restart the panel PC and investigate any software causing excessive CPU usage. - Event ID: 300
- Fan failure detected — the internal cooling fan has stopped or is running below the required speed.
Inspect and clean the fan. Replace the fan unit if it is defective to prevent thermal shutdown. - Event ID: 400
- Temperature warning — internal temperature has exceeded the defined threshold.
Check ambient temperature and ventilation around the panel. Clean air filters and ensure the panel cutout provides adequate clearance. - Event ID: 500
- Battery low warning — the CMOS backup battery voltage is below the minimum threshold.
Replace the internal CMOS battery (typically CR2032 or equivalent) to prevent loss of BIOS settings and real-time clock data. - Event ID: 600
- Ethernet communication failure — network connection to the controller or SCADA system has been lost.
Check Ethernet cable connections, switch/hub status, and IP configuration. Verify that the network adapter driver is functioning correctly in Device Manager. - Event ID: 700
- HMI software runtime error — the WinCC or ProTool/Pro runtime application has terminated unexpectedly.
Review the application event log for error details. Restart the runtime software and check for project configuration errors or corrupted project files.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7611-0AF12-0CH0) run?
The SIMATIC Panel PC 670 is typically supplied with Windows XP Professional or Windows 2000 Professional as the operating system, depending on the specific order configuration.
What HMI software is compatible with this panel PC?
The 6AV7611-0AF12-0CH0 is compatible with Siemens WinCC, WinCC flexible, and ProTool/Pro RT, as well as other standard Windows-based SCADA and visualization software.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, providing protection against dust ingress and low-pressure water jets.
Can the storage medium be replaced or upgraded?
Yes, the SIMATIC Panel PC 670 supports replaceable storage media. Depending on the configuration, it may use a hard disk drive or a CompactFlash card, both of which can be replaced or upgraded.
What is the supply voltage for the 6AV7611-0AF12-0CH0?
This panel PC operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel-mounted devices.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power supply connector. Verify that the backlight is not simply dimmed by checking display brightness settings in the BIOS or OS.
If supply voltage is correct but display remains blank, inspect the internal backlight inverter board and replace if faulty. Also check the display cable connection between the mainboard and the panel.
Touchscreen does not respond or is misaligned
Attempt to recalibrate the touchscreen using the calibration utility available in the Windows control panel or Siemens panel configuration tool. Check for physical damage to the touch surface.
Run the touchscreen calibration routine. If calibration fails or the screen remains unresponsive, the resistive touch overlay may need to be replaced.
Panel PC fails to boot and shows BIOS error
Check if the CMOS battery is depleted, which can cause BIOS settings to reset. Also verify that the hard disk or CompactFlash storage medium is correctly seated and detected in BIOS.
Replace the CMOS battery and re-enter BIOS settings. If the storage medium is not detected, reseat or replace it and restore the OS image using the Siemens recovery procedure.
Ethernet communication lost with PLC or SCADA system
Verify physical Ethernet cable integrity and check the link indicator LEDs on the RJ45 port. Confirm IP address settings in Windows Network Connections match the expected network configuration.
Replace the Ethernet cable if damaged. Reconfigure the IP address if incorrect. Update or reinstall the network adapter driver if the adapter is not recognized in Device Manager.
System overheats and shuts down unexpectedly
Check the ambient temperature around the panel installation. Inspect the ventilation slots and any cooling fans for blockage by dust or debris.
Clean all ventilation openings and fan assemblies. Ensure the installation environment does not exceed 45 °C. Replace the cooling fan if it is not operating correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page