Siemens 6AV7611-0AF20-0AE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF20-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit combines a flat-panel display with an integrated industrial PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7611-0AF20-0AE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an industrial-grade processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45) and serial ports (RS-232), and is built to withstand industrial environments with a front panel protection rating of IP65. Expansion slots allow for additional interface cards, and the system supports standard PC peripherals via USB and PS/2 ports.
The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, chemical, and food and beverage industries for machine-level and plant-level visualization. It is suitable for applications requiring a full PC-based HMI platform, such as SCADA visualization, recipe management, data logging, and integration with SIMATIC S7 PLC systems. Its rugged construction and industrial-grade components make it appropriate for continuous operation in factory floor environments where reliability and long service life are essential.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet (RJ45), RS-232 (COM ports), USB, PS/2 |
| Operating System | Microsoft Windows XP / Windows 2000 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cUL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly, possibly due to corrupted system files or a failed hard disk.
Check the hard disk or Compact Flash card for errors. Reinstall the operating system or replace the storage medium if faulty. - Event ID: 101
- Hardware initialization failure — a hardware component such as RAM or a peripheral card was not recognized during POST.
Reseat RAM modules and expansion cards. Run BIOS diagnostics to identify the faulty component and replace if necessary. - Event ID: 200
- Fan failure detected — the internal cooling fan has stopped or is running below the required speed threshold.
Inspect and clean the fan. Replace the fan unit if it is not operating correctly to prevent thermal shutdown. - Event ID: 201
- Overtemperature warning — the internal temperature of the Panel PC has exceeded the permissible operating threshold.
Check ambient temperature and ensure ventilation clearances are maintained. Clean air filters and verify fan operation. - Event ID: 300
- Ethernet communication error — loss of network connectivity detected on the onboard Ethernet interface.
Check Ethernet cable connections and network switch configuration. Verify IP address settings and network driver installation in the operating system. - Event ID: 400
- WinCC Runtime error — the SIMATIC WinCC visualization software has encountered a runtime fault and terminated unexpectedly.
Review the WinCC diagnostic log for specific error details. Reinstall WinCC Runtime if the issue persists or restore from a known-good project backup. - Event ID: 500
- UPS battery low — the connected uninterruptible power supply has reported a low battery condition.
Replace the UPS battery. Verify UPS communication settings and ensure the battery is within its service life.
Frequently Asked Questions
What display size and resolution does the 6AV7611-0AF20-0AE0 provide?
This unit features a 12-inch TFT color LCD with a resolution of 800 x 600 pixels (SVGA) and resistive touchscreen input.
What operating system does the SIMATIC Panel PC 670 6AV7611-0AF20-0AE0 run?
The unit is designed to run Microsoft Windows XP or Windows 2000, and is compatible with SIMATIC WinCC and other Siemens HMI software packages.
What communication interfaces are available on this Panel PC?
The 6AV7611-0AF20-0AE0 provides Ethernet (RJ45), RS-232 serial ports, USB ports, and PS/2 connectors for keyboard and mouse.
What is the supply voltage for this Panel PC?
The unit operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted equipment in automation environments.
Is the 6AV7611-0AF20-0AE0 compatible with SIMATIC S7 PLCs?
Yes, the Panel PC 670 supports communication with SIMATIC S7-300 and S7-400 PLCs via Ethernet or through optional PROFIBUS interface cards, using SIMATIC WinCC or STEP 7 software.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is illuminated. Inspect internal fuses and the backlight inverter board.
Restore correct supply voltage if out of range. Replace the backlight lamp or inverter board if the display is not illuminating. Replace the internal power supply module if no voltage is present at the board.
Touchscreen does not respond or responds inaccurately
Check whether the touchscreen controller is recognized in the Windows Device Manager. Verify that the touchscreen calibration has not been corrupted.
Recalibrate the touchscreen using the Siemens touchscreen calibration utility in the Control Panel. If the controller is not recognized, reinstall the touchscreen driver or replace the touchscreen overlay.
Panel PC fails to boot and displays a BIOS error or stops at POST
Inspect the Compact Flash card or hard disk for physical damage or loose connections. Check RAM seating and expansion cards.
Reseat the storage medium and RAM. If the storage device is faulty, replace it and reinstall the operating system and WinCC software from the Siemens recovery image.
Ethernet communication to PLC or network is lost intermittently
Check the Ethernet cable and RJ45 connector for damage. Verify network settings including IP address, subnet mask, and gateway in the Windows network configuration.
Replace the Ethernet cable if damaged. Reconfigure network settings as required. Update the Ethernet driver if the interface is not functioning correctly after hardware checks.
System overheats and shuts down unexpectedly
Measure the ambient temperature at the installation location. Inspect the ventilation slots and internal fan for dust blockage or fan failure.
Clean ventilation slots and the internal fan with compressed air. Ensure minimum clearance distances around the unit are maintained. Replace the cooling fan if it is not operating at the correct speed.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page