Siemens 6AV7611-0AF12-0BH0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF12-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, providing a compact and robust solution for process visualization and control.
The 6AV7611-0AF12-0BH0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors, offering clear visualization of process data. The unit is built around an industrial-grade processor and supports standard PC interfaces including USB, Ethernet, and serial ports for connectivity to PLCs and peripheral devices. It is designed for front-panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress in industrial settings. The unit runs on a 24 V DC supply and is compatible with Windows-based operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages.
The SIMATIC Panel PC 670 series is widely used in manufacturing, process automation, and machine building applications where a full PC-based HMI platform is required. Its compatibility with Siemens SIMATIC software and standard industrial communication protocols makes it suitable for integration into existing SIMATIC automation architectures. Typical deployment environments include automotive production lines, chemical processing plants, and packaging machinery where reliable visualization and data processing are essential.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 64,000 colors |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Mounting | Front panel mounting |
| Communication Interfaces | Ethernet (RJ45), USB, RS-232 |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System Compatibility | Windows XP, Windows CE |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify boot device is correctly configured in BIOS. Replace storage medium if faulty. - Event ID: 200
- Fan failure or thermal warning — internal cooling fan not operating within specified parameters.
Inspect and clean the cooling fan. Replace the fan unit if it has failed. Ensure ambient temperature is within the specified operating range. - Event ID: 300
- Watchdog timeout — the system watchdog has triggered due to an application or OS hang.
Restart the Panel PC. Investigate the running application for software loops or resource conflicts. Update or reinstall the HMI application if the issue persists. - Event ID: 400
- Communication error on Ethernet interface — loss of connection to PLC or network device.
Check Ethernet cable and connector integrity. Verify network switch and IP configuration. Confirm PLC communication settings match the Panel PC configuration. - Event ID: 500
- Backlight failure — display backlight has failed or reached end of service life.
Replace the display backlight or inverter board. If the unit uses a CCFL backlight, replace the lamp assembly. Contact Siemens service for display module replacement. - Event ID: 600
- Power supply undervoltage — supply voltage has dropped below the 24 V DC operating threshold.
Measure the 24 V DC supply at the power connector. Ensure the power supply unit is rated adequately for the load. Check wiring for voltage drop or loose connections. - Event ID: 700
- Touch screen calibration error — touch input is not responding correctly or is misaligned.
Perform a touch screen recalibration via the Windows control panel or SIMATIC configuration tool. Clean the touch surface. Replace the touch overlay if calibration fails repeatedly.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AF12-0BH0?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 series devices.
What is the display size and resolution of this Panel PC?
The 6AV7611-0AF12-0BH0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors.
Is this Panel PC compatible with SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC and other Windows-based HMI software packages, as it runs a standard Windows operating system.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AF12-0BH0 carries an IP65 protection rating, providing full dust protection and resistance to water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces for connectivity to PLCs, network devices, and peripherals.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify the backlight is functioning by shining a light at the display surface to check for a faint image.
If supply voltage is correct but display is blank, replace the backlight inverter or CCFL lamp assembly. If no image is visible at all, inspect the display cable connections internally and replace the display module if necessary.
Touch screen does not respond or responds inaccurately
Attempt to operate the unit using an external USB mouse to determine if the issue is isolated to the touch overlay. Check for physical damage or contamination on the touch surface.
Perform a touch screen recalibration through the Windows control panel. Clean the touch surface with a soft, dry cloth. If recalibration does not resolve the issue, replace the touch screen overlay.
Panel PC fails to boot or repeatedly restarts
Observe the boot sequence for error messages during POST. Check the CompactFlash card or hard disk drive for errors using a diagnostic tool. Verify that the operating system partition is intact.
Replace the CompactFlash card or hard disk drive with a correctly imaged replacement. Restore the operating system and HMI application from a backup image. Ensure BIOS settings are correctly configured for the boot device.
Loss of communication with PLC or network
Check the Ethernet cable and RJ45 connector for damage. Verify the IP address configuration on the Panel PC matches the network settings. Use a network ping test to determine if the device is reachable.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings in Windows network settings. If the Ethernet port is faulty, use a USB-to-Ethernet adapter as a temporary measure and arrange for hardware repair.
Unit overheating or thermal shutdown
Check that the ambient temperature is within the 0 °C to 45 °C operating range. Inspect the ventilation slots and cooling fan for blockage or dust accumulation.
Clean the cooling fan and ventilation slots using compressed air. Ensure adequate clearance around the unit for airflow. If the fan has failed, replace it with the correct spare part. Reduce ambient temperature if it exceeds the specified limit.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page