
Siemens 6AV7611-0AF12-0BJ0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF12-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a fully functional industrial PC platform, providing a compact and rugged all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is built to withstand industrial environments with a front panel protection rating of IP65. An internal CompactFlash slot and hard disk drive provide flexible storage options.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a robust, integrated PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its fanless front panel design and industrial-grade components make it well suited for continuous operation in environments with dust, humidity, and vibration.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Processor | Intel Celeron |
| Operating System | Windows XP / Windows 2000 |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM ports) |
| Storage | CompactFlash slot, internal hard disk drive |
| Input/Operating Voltage | 24 V DC |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the hard disk drive and CompactFlash card for integrity. Verify the OS installation and boot configuration. Replace storage media if corrupted. - Event ID: 1000
- Application fault — a running HMI application such as WinCC has crashed or become unresponsive.
Restart the application. Check the Windows Event Viewer for detailed error logs. Reinstall the HMI software if the fault persists. - Event ID: 6008
- Unexpected system shutdown — the Panel PC was powered off without a proper shutdown sequence.
Investigate power supply stability at the 24 V DC input. Ensure proper shutdown procedures are followed. Check for loose wiring at the power connector. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or field device via Ethernet or serial interface.
Verify Ethernet cable connections and network configuration. Check IP address settings and firewall rules. Inspect RS-232 cable wiring and COM port settings. - Watchdog Timeout
- The system watchdog timer has triggered, indicating the CPU or application has stopped responding within the expected time frame.
Restart the Panel PC. Check for excessive CPU load or memory usage. Investigate application software for infinite loops or resource leaks. - Hard Disk Fault
- The internal hard disk drive has reported an error or is not detected during POST.
Run a disk diagnostic utility. Back up data immediately if the disk is still accessible. Replace the hard disk drive with a compatible industrial-grade unit. - Temperature Warning
- The internal temperature of the Panel PC has exceeded the recommended operating threshold.
Check that ambient temperature is within the specified 0 °C to +45 °C range. Ensure adequate ventilation around the unit. Clean any dust from ventilation openings. - Display Backlight Failure
- The TFT display backlight has failed or is producing insufficient brightness.
Check the backlight inverter board and connections. Replace the CCFL backlight lamp or the display assembly if the inverter is functioning correctly.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7611-0AF12-0BJ0?
The Panel PC 670 operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.
What HMI software is compatible with this Panel PC?
The unit is compatible with Siemens SIMATIC WinCC, WinCC flexible, and ProTool/Pro RT software packages. It runs on Windows XP or Windows 2000 operating systems.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust ingress and water jets. The rear of the unit is rated IP20.
Does this Panel PC support communication with S7 PLCs?
Yes, the Panel PC 670 can communicate with Siemens S7-300 and S7-400 PLCs via Ethernet using the SIMATIC communication protocols supported by WinCC. Additional communication cards can extend connectivity options.
What storage options are available on this Panel PC?
The unit includes an internal hard disk drive for the operating system and application data, as well as a CompactFlash slot for additional or removable storage.
Troubleshooting
Panel PC does not power on after applying 24 V DC supply
Measure the supply voltage at the power input connector to confirm 24 V DC is present and within tolerance. Check the internal fuse on the power supply board.
Replace the internal fuse if blown. If the supply voltage is correct and the fuse is intact, the internal power supply module may require replacement or professional repair.
Display is blank but the system appears to be running (HDD activity LED active)
Check the display backlight by observing the screen closely with a flashlight to determine if an image is present without backlight illumination. Inspect the backlight inverter and its cable connections.
Replace the CCFL backlight lamp or the backlight inverter board. If the display shows no image at all, check the video signal cable between the motherboard and the display panel.
Touch screen input is inaccurate or unresponsive
Verify that the touch screen calibration has not been lost. Check the touch controller cable connection between the display assembly and the motherboard.
Recalibrate the touch screen using the Windows control panel or the Siemens calibration utility. If the issue persists, inspect and reseat the touch controller cable or replace the touch screen overlay.
Panel PC loses network communication with the PLC intermittently
Check the Ethernet cable and RJ45 connector for physical damage or loose connection. Verify the IP address configuration and subnet settings in Windows network settings.
Replace the Ethernet cable if damaged. Assign a static IP address to avoid DHCP-related issues. Update the network adapter driver if communication drops occur after OS startup.
System boots slowly or fails to load the HMI application at startup
Check the hard disk drive health using a diagnostic tool such as CrystalDiskInfo. Review the Windows Event Viewer for startup errors or application conflicts.
Defragment or replace the hard disk drive if it shows signs of failure. Disable unnecessary startup programs to reduce boot time. Consider migrating the OS to a CompactFlash or SSD solution for improved reliability.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page



