• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AE32-0CJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AE32-0CJ0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AE32-0CJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AE32-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface and visualization tasks in automation environments. The unit integrates a display, computing hardware, and industrial I/O into a single compact enclosure suitable for direct panel mounting.

    The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels and a touch-sensitive front panel for operator interaction. It is powered by an Intel Celeron processor and runs Microsoft Windows XP or Windows XP Embedded, supporting SIMATIC WinCC and other SCADA visualization software. The unit provides communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), and is built with an IP65-rated front panel for protection against dust and water ingress in industrial environments.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine visualization applications across industries such as automotive, food and beverage, chemical processing, and packaging. Its rugged construction and compatibility with Siemens SIMATIC software make it suitable for integration into existing Siemens automation architectures. The unit is typically deployed as a central operator station on production lines or as a visualization node in distributed control systems.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Power Consumption 60 W (typical)
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet (RJ45), USB 2.0, RS-232/RS-422/RS-485
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 100001
    Loss of communication between Panel PC and connected PLC or SCADA system
    Check Ethernet or serial cable connections, verify IP address configuration, and confirm the PLC or server is online and reachable.
    Event ID: 100002
    Runtime software (WinCC flexible or WinCC) has encountered a configuration error or failed to start
    Restart the runtime application, verify the project file integrity, and re-download the project from the engineering station if necessary.
    Event ID: 100003
    Operating system startup failure or Windows boot error
    Check the Compact Flash card or hard disk for errors using Windows disk check tools. Re-image the storage medium if the OS is corrupted.
    Event ID: 100004
    Touchscreen calibration error or touch input not responding correctly
    Re-run the touchscreen calibration utility from the Windows Control Panel or the SIMATIC configuration tool.
    Event ID: 100005
    Internal temperature warning — processor or system temperature exceeds threshold
    Check that ventilation slots are unobstructed, verify ambient temperature is within specification, and inspect internal cooling components if accessible.
    Event ID: 100006
    24 V DC supply voltage out of range
    Measure the supply voltage at the power connector and ensure it is within the specified 24 V DC tolerance range. Check the power supply unit feeding the Panel PC.
    Event ID: 100007
    Storage medium (Compact Flash or HDD) failure or read/write error
    Back up data immediately if possible, run a disk diagnostic, and replace the Compact Flash card or hard disk drive as required.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 (6AV7611-0AE32-0CJ0) run?

    This unit runs Microsoft Windows XP or Windows XP Embedded, which supports SIMATIC WinCC and WinCC flexible visualization software.

    What is the display size and resolution of this Panel PC?

    The 6AV7611-0AE32-0CJ0 features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).

    What communication interfaces are available on this unit?

    The Panel PC 670 provides Ethernet (RJ45), USB 2.0 ports, and serial interfaces (RS-232/RS-422/RS-485) for connectivity to PLCs, networks, and peripherals.

    What is the front panel protection rating of this Panel PC?

    The front panel is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial panel installation.

    Is this Panel PC compatible with Siemens SIMATIC WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and WinCC flexible, and integrates directly into Siemens SIMATIC automation environments.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the power LED status. Measure voltage at the internal power supply output to the display backlight.

    Ensure the 24 V DC supply is within tolerance. If the backlight has failed, the backlight inverter or display assembly may need replacement. If no power is detected, inspect internal fuses and the power supply module.

    Touchscreen does not respond or registers incorrect touch positions

    Determine whether the issue is a calibration problem or a hardware failure by attempting to recalibrate the touch panel via the Windows Control Panel.

    Run the touchscreen calibration utility. If calibration does not resolve the issue, check the touch controller connection to the mainboard and replace the touchscreen assembly if the hardware is faulty.

    Panel PC fails to boot Windows or shows a boot error

    Check the Compact Flash card or hard disk drive for physical damage or loose connections. Attempt to boot into Windows Safe Mode to isolate software versus hardware faults.

    Run Windows disk check (chkdsk) to repair file system errors. If the storage medium is corrupted beyond repair, re-image it using a Siemens recovery image or replace the Compact Flash card with a pre-imaged replacement.

    Communication with PLC or SCADA server is lost intermittently

    Check the Ethernet cable and RJ45 connector for damage or loose fit. Verify the IP address, subnet mask, and gateway settings in Windows Network Connections.

    Replace the Ethernet cable if damaged. Reconfigure the network settings to match the plant network. If the issue persists, test the Ethernet port with a known-good device and replace the network interface card if faulty.

    WinCC runtime application crashes or does not start

    Review the Windows Event Viewer logs and the WinCC diagnostic files for error messages. Check available disk space and RAM usage.

    Free up disk space if storage is full, reinstall the WinCC runtime if files are corrupted, and re-download the project from the engineering station. Ensure the Windows XP installation is up to date with required service packs.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart