Siemens 6AV7611-0AE32-0CJ0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE32-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface and visualization tasks in automation environments. The unit integrates a display, computing hardware, and industrial I/O into a single compact enclosure suitable for direct panel mounting.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels and a touch-sensitive front panel for operator interaction. It is powered by an Intel Celeron processor and runs Microsoft Windows XP or Windows XP Embedded, supporting SIMATIC WinCC and other SCADA visualization software. The unit provides communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), and is built with an IP65-rated front panel for protection against dust and water ingress in industrial environments.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine visualization applications across industries such as automotive, food and beverage, chemical processing, and packaging. Its rugged construction and compatibility with Siemens SIMATIC software make it suitable for integration into existing Siemens automation architectures. The unit is typically deployed as a central operator station on production lines or as a visualization node in distributed control systems.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | 60 W (typical) |
| IP/Protection Rating | IP65 (front panel) |
| Communication Interface | Ethernet (RJ45), USB 2.0, RS-232/RS-422/RS-485 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100001
- Loss of communication between Panel PC and connected PLC or SCADA system
Check Ethernet or serial cable connections, verify IP address configuration, and confirm the PLC or server is online and reachable. - Event ID: 100002
- Runtime software (WinCC flexible or WinCC) has encountered a configuration error or failed to start
Restart the runtime application, verify the project file integrity, and re-download the project from the engineering station if necessary. - Event ID: 100003
- Operating system startup failure or Windows boot error
Check the Compact Flash card or hard disk for errors using Windows disk check tools. Re-image the storage medium if the OS is corrupted. - Event ID: 100004
- Touchscreen calibration error or touch input not responding correctly
Re-run the touchscreen calibration utility from the Windows Control Panel or the SIMATIC configuration tool. - Event ID: 100005
- Internal temperature warning — processor or system temperature exceeds threshold
Check that ventilation slots are unobstructed, verify ambient temperature is within specification, and inspect internal cooling components if accessible. - Event ID: 100006
- 24 V DC supply voltage out of range
Measure the supply voltage at the power connector and ensure it is within the specified 24 V DC tolerance range. Check the power supply unit feeding the Panel PC. - Event ID: 100007
- Storage medium (Compact Flash or HDD) failure or read/write error
Back up data immediately if possible, run a disk diagnostic, and replace the Compact Flash card or hard disk drive as required.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7611-0AE32-0CJ0) run?
This unit runs Microsoft Windows XP or Windows XP Embedded, which supports SIMATIC WinCC and WinCC flexible visualization software.
What is the display size and resolution of this Panel PC?
The 6AV7611-0AE32-0CJ0 features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
What communication interfaces are available on this unit?
The Panel PC 670 provides Ethernet (RJ45), USB 2.0 ports, and serial interfaces (RS-232/RS-422/RS-485) for connectivity to PLCs, networks, and peripherals.
What is the front panel protection rating of this Panel PC?
The front panel is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial panel installation.
Is this Panel PC compatible with Siemens SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and WinCC flexible, and integrates directly into Siemens SIMATIC automation environments.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the power LED status. Measure voltage at the internal power supply output to the display backlight.
Ensure the 24 V DC supply is within tolerance. If the backlight has failed, the backlight inverter or display assembly may need replacement. If no power is detected, inspect internal fuses and the power supply module.
Touchscreen does not respond or registers incorrect touch positions
Determine whether the issue is a calibration problem or a hardware failure by attempting to recalibrate the touch panel via the Windows Control Panel.
Run the touchscreen calibration utility. If calibration does not resolve the issue, check the touch controller connection to the mainboard and replace the touchscreen assembly if the hardware is faulty.
Panel PC fails to boot Windows or shows a boot error
Check the Compact Flash card or hard disk drive for physical damage or loose connections. Attempt to boot into Windows Safe Mode to isolate software versus hardware faults.
Run Windows disk check (chkdsk) to repair file system errors. If the storage medium is corrupted beyond repair, re-image it using a Siemens recovery image or replace the Compact Flash card with a pre-imaged replacement.
Communication with PLC or SCADA server is lost intermittently
Check the Ethernet cable and RJ45 connector for damage or loose fit. Verify the IP address, subnet mask, and gateway settings in Windows Network Connections.
Replace the Ethernet cable if damaged. Reconfigure the network settings to match the plant network. If the issue persists, test the Ethernet port with a known-good device and replace the network interface card if faulty.
WinCC runtime application crashes or does not start
Review the Windows Event Viewer logs and the WinCC diagnostic files for error messages. Check available disk space and RAM usage.
Free up disk space if storage is full, reinstall the WinCC runtime if files are corrupted, and re-download the project from the engineering station. Ensure the Windows XP installation is up to date with required service packs.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page