Siemens 6AV7611-0AE32-0BF0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE32-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC architecture, enabling both operator control and data processing within a single compact device.
The SIMATIC Panel PC 670 (6AV7611-0AE32-0BF0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an x86-compatible processor platform and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides standard PC interfaces including USB ports, serial COM ports, and Ethernet connectivity, and is designed for front-panel mounting with an IP65 protection rating on the front face. Onboard memory and storage options allow for reliable operation of visualization and SCADA applications.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a robust, industrially hardened PC-based HMI solution is required. Its fanless or low-maintenance design variants make it suitable for environments with dust, vibration, and temperature fluctuations. Industries such as automotive, food and beverage, chemical processing, and discrete manufacturing commonly deploy this panel PC for supervisory control and data acquisition tasks.
Technical Specifications
| Series | SIMATIC Panel PC 670 |
|---|---|
| Display Size | 12 inch |
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM) |
| Mounting | Panel mounting (front flush) |
| Certifications | CE, UL |
Common Error Codes and System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly or a critical system file is missing.
Check the storage medium (CompactFlash or hard disk) for integrity. Reinstall or restore the operating system image using the Siemens recovery tool. - Event ID: 1000
- Application crash — a WinCC or HMI runtime application has terminated unexpectedly.
Review the Windows Event Viewer log for the faulting module. Reinstall the HMI runtime software or apply the relevant Siemens software patch. - Event ID: 26
- Disk write error — the system was unable to write data to the storage device.
Check available disk space and the health of the CompactFlash card or hard drive. Replace the storage medium if errors persist. - Hardware Watchdog Timeout
- The hardware watchdog timer has triggered a system reset due to an application or OS hang.
Investigate the cause of the system hang. Check CPU load, memory usage, and application stability. Update drivers or runtime software as needed. - Network Connection Lost
- The Ethernet interface has lost communication with the connected PLC or SCADA server.
Verify Ethernet cable connections and switch/hub status. Check IP address configuration and firewall settings on the Panel PC and the connected controller. - Touch Screen Not Responding
- The resistive touch input is not registering operator inputs correctly or at all.
Recalibrate the touchscreen via the Windows Control Panel or Siemens calibration utility. If calibration fails, inspect the touch controller hardware and replace the touch overlay if damaged. - Temperature Warning
- The internal temperature sensor has detected an operating temperature above the specified threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean any dust from ventilation slots and verify that the installation environment is within the 0 °C to +45 °C operating range.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7611-0AE32-0BF0) support?
This Panel PC is designed to run Microsoft Windows XP Professional or Windows XP Embedded, and is compatible with Siemens SIMATIC WinCC and ProTool/Pro runtime software.
What is the supply voltage for the 6AV7611-0AE32-0BF0?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7611-0AE32-0BF0 carries an IP65 protection rating, making it resistant to dust and water jets when correctly installed in a panel cutout.
Can this Panel PC communicate directly with Siemens S7 PLCs?
Yes, via the onboard Ethernet interface and appropriate communication drivers (such as SIMATIC NET), the Panel PC 670 can communicate with S7-300 and S7-400 PLCs using protocols such as S7 communication and PROFINET.
Is the touchscreen on the 6AV7611-0AE32-0BF0 resistive or capacitive?
The touchscreen on this unit is resistive technology, which allows operation with gloves and is well suited to industrial environments.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector. Check the internal fuse and verify that the power supply unit is delivering correct voltage to the mainboard.
Replace the internal fuse if blown. If the power supply module is faulty, replace it. Ensure the 24 V DC supply source is stable and within tolerance.
Display is blank but the system appears to be running (HDD activity, network active)
Check the display backlight by shining a torch at the screen to see if a faint image is visible. Verify the display cable connection between the mainboard and the LCD panel.
Replace the CCFL backlight or inverter board if the backlight has failed. If the display cable is loose or damaged, reseat or replace it. In some cases, the LCD panel itself may require replacement.
Touchscreen input is inaccurate or offset from the displayed image
This is typically a touchscreen calibration issue. Access the Windows Control Panel or the Siemens touchscreen calibration utility to assess current calibration accuracy.
Run the touchscreen calibration routine from within Windows. If the calibration cannot be saved due to a write-protected storage medium, check the CompactFlash write-protect settings and recalibrate.
Panel PC freezes or reboots unexpectedly during operation
Check the Windows Event Viewer for critical errors or watchdog events. Monitor CPU temperature and system resource usage. Inspect the CompactFlash card or hard drive for read/write errors using diagnostic tools.
Ensure the operating environment is within the specified temperature range. Replace the storage medium if errors are detected. Update or reinstall the HMI runtime software if a software fault is identified.
Ethernet communication to PLC is intermittent or lost
Check the Ethernet cable and connector for physical damage. Verify the IP address configuration on the Panel PC and the connected PLC or network switch. Use the Windows network diagnostics to ping the target device.
Replace the Ethernet cable if damaged. Reconfigure the IP settings if there is an address conflict. Update the SIMATIC NET communication software if driver-level issues are suspected.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page