• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AE32-0BG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AE32-0BG0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AE32-0BG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AE32-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates computing power and display functionality into a single compact panel-mount device, running a Windows-based operating system suitable for SCADA and HMI software platforms.

    The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels and a touch-sensitive screen for operator interaction. It is equipped with an Intel Celeron processor and supports standard industrial communication interfaces including Ethernet (RJ45) and USB ports, enabling integration with Siemens SIMATIC WinCC and other visualization software. The unit is designed for front-panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress in industrial settings. It operates on a 24 V DC supply and is built to withstand the temperature and vibration conditions typical of factory floor environments.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, panel-mounted computing solution is required. It is suitable for applications such as production line visualization, process monitoring, and machine control interfaces. Its compatibility with Siemens SIMATIC software ecosystem makes it a practical choice for integration into existing Siemens automation architectures.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    IP Rating (Front) IP65
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5% to 95% (non-condensing)
    Communication Interface Ethernet RJ45, USB
    Operating System Windows XP Embedded
    Mounting Panel mounting
    Certifications CE, UL
    Series/Product Family SIMATIC Panel PC 670

    Common Error Codes & System Events

    Event ID: 1000
    Application error or unexpected software exception on the Panel PC operating system.
    Check Windows Event Viewer for detailed error logs. Restart the application or reboot the Panel PC. Reinstall the HMI runtime software if the error persists.
    Event ID: 6008
    The system shut down unexpectedly, indicating a previous unclean shutdown or power loss.
    Check the 24 V DC power supply for stability and correct voltage level. Inspect power connectors and cabling. Review event logs for preceding errors.
    Communication Error
    Loss of communication between the Panel PC and the connected PLC or automation controller.
    Verify Ethernet cable connections and network configuration. Check IP address settings and ensure the PLC is online. Review firewall and network switch settings.
    Watchdog Timeout
    The system watchdog has detected that the operating system or application has stopped responding.
    Perform a controlled restart of the Panel PC. Check for software conflicts or excessive CPU load. Update or reinstall the HMI runtime if the issue recurs.
    Hard Disk Error
    The internal storage device (CompactFlash or hard disk) has reported a read/write error or failure.
    Back up project data immediately if possible. Run a disk check utility. Replace the internal storage medium if errors are confirmed.
    Temperature Warning
    The internal temperature of the Panel PC has exceeded the recommended operating threshold.
    Check ambient temperature around the panel. Ensure ventilation slots are not obstructed. Verify that the cooling fan (if present) is operational and clean.
    Display Backlight Failure
    The display backlight has failed or is operating at reduced brightness, resulting in a dim or blank screen.
    Check backlight power connections internally. Replace the backlight inverter board or the display unit if the backlight does not illuminate after power cycling.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7611-0AE32-0BG0?

    The unit operates on a 24 V DC power supply. Ensure the supply is stable and within the specified tolerance range to avoid system faults.

    What operating system does the SIMATIC Panel PC 670 run?

    The 6AV7611-0AE32-0BG0 runs Windows XP Embedded, which is compatible with Siemens SIMATIC WinCC and other standard HMI visualization software.

    What is the front panel protection rating of this Panel PC?

    The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, providing protection against dust and low-pressure water jets.

    Is this Panel PC compatible with Siemens SIMATIC WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to run Siemens SIMATIC WinCC and WinCC flexible visualization software, making it directly compatible with Siemens automation systems.

    What communication interfaces are available on this unit?

    The unit provides Ethernet (RJ45) and USB interfaces for connectivity to PLCs, networks, and peripheral devices.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is active. Measure voltage at the display backlight inverter.

    If supply voltage is correct but display is blank, replace the backlight inverter or the display assembly. If no power LED is present, inspect internal fuses and the power supply board.

    Touchscreen does not respond to input

    Check if the operating system has fully booted by connecting an external USB mouse or keyboard. Verify touchscreen driver status in Windows Device Manager.

    Recalibrate the touchscreen using the Windows calibration utility. If calibration fails, reinstall the touchscreen driver. If hardware is unresponsive, replace the touchscreen overlay.

    Panel PC fails to boot or continuously restarts

    Check the internal CompactFlash card or hard disk for errors using a bootable diagnostic tool. Inspect for Windows boot errors displayed on screen during startup.

    Replace the internal storage medium if disk errors are confirmed. Restore the operating system image from a backup. Ensure the 24 V DC supply is stable and free from voltage drops.

    Loss of communication with PLC

    Verify Ethernet cable integrity and connection at both the Panel PC and PLC ends. Check IP address configuration in the network settings of the Panel PC.

    Correct any IP address conflicts or misconfiguration. Replace the Ethernet cable if damaged. If the network adapter is faulty, service or replace the Panel PC mainboard.

    Panel PC overheating or shutting down due to high temperature

    Measure the ambient temperature around the panel installation. Check that ventilation openings are not blocked by dust or debris. Inspect the internal cooling fan for operation.

    Clean ventilation slots and the cooling fan with compressed air. Ensure the installation environment does not exceed 45 degrees C. Add external cooling or improve cabinet ventilation if necessary.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart