
Siemens 6AV7611-0AE32-0BE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE32-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit combines a high-performance computing platform with a robust industrial enclosure, providing a complete PC-based HMI solution in a single integrated device.
The SIMATIC Panel PC 670 6AV7611-0AE32-0BE0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen interface. It is powered by an Intel Celeron processor and supports Windows XP Professional or Windows XP Embedded as its operating system. The unit includes standard PC interfaces such as USB, Ethernet (RJ45), serial COM ports, and a PCI expansion slot for additional communication cards. It is designed for front-panel mounting with an IP65-rated front panel, protecting against dust and water ingress in industrial settings.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC-based HMI platform is required. Its compatibility with Siemens WinCC and other SCADA software makes it suitable for complex visualization tasks in automotive, food and beverage, chemical, and general manufacturing industries. The integrated design reduces installation complexity and footprint compared to separate PC and display solutions.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Processor | Intel Celeron |
| Operating System | Windows XP Professional / Windows XP Embedded |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM ports) |
| Expansion | 1 x PCI slot |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting (front mount) |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Watchdog timeout triggered, indicating the application software has stopped responding.
Restart the Panel PC. Check the HMI application for software errors or infinite loops. Update or reinstall the WinCC or HMI runtime software. - Event ID: 300
- Fan failure or thermal warning detected. Internal cooling fan has stopped or CPU temperature exceeds threshold.
Inspect and clean the cooling fan and ventilation slots. Replace the internal fan if defective. Ensure ambient temperature is within specification. - Event ID: 400
- Ethernet communication fault. Network interface is not detected or connection to PLC/SCADA system is lost.
Check Ethernet cable and connector integrity. Verify network configuration (IP address, subnet mask). Inspect the NIC hardware and replace if necessary. - Event ID: 500
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen using the Windows control panel or SIMATIC calibration utility. If the issue persists, check the touchscreen controller connection or replace the touchscreen assembly. - Event ID: 600
- Power supply undervoltage detected. Supply voltage has dropped below the permissible 24 V DC operating range.
Measure the 24 V DC supply at the power connector. Ensure the power supply unit provides stable voltage within tolerance. Replace the power supply if voltage is out of range. - Event ID: 700
- Hard disk or CompactFlash storage device read/write error or device not found.
Check storage device seating and connections. Run a disk diagnostic utility. Replace the hard disk or CompactFlash card if errors are confirmed.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AE32-0BE0?
The SIMATIC Panel PC 670 6AV7611-0AE32-0BE0 operates on a 24 V DC supply voltage.
What display size and resolution does this Panel PC have?
The unit features a 12-inch TFT color LCD display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen.
Which operating systems are supported by this Panel PC?
The 6AV7611-0AE32-0BE0 supports Windows XP Professional and Windows XP Embedded as its operating system.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and other SIMATIC HMI software packages, making it suitable for SCADA and visualization applications.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AE32-0BE0 carries an IP65 protection rating, providing full protection against dust and low-pressure water jets.
Troubleshooting
Panel PC does not boot or display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the storage device (hard disk or CompactFlash) is properly seated and recognized in BIOS.
Restore the correct 24 V DC supply. Reseat or replace the storage device. If the display remains blank, check the backlight inverter and display cable connections.
Touchscreen does not respond or registers incorrect touch positions
Determine whether the issue is a calibration problem or a hardware fault by attempting recalibration via the Windows control panel.
Recalibrate the touchscreen using the SIMATIC calibration tool or Windows Tablet PC settings. If recalibration fails, inspect the touchscreen controller board connections and replace the touchscreen assembly if necessary.
Panel PC overheats and shuts down unexpectedly
Check the internal cooling fan operation and inspect ventilation slots for blockages. Measure the ambient temperature around the unit.
Clean dust from ventilation slots and the cooling fan. Replace the fan if it is not spinning. Ensure the ambient operating temperature does not exceed 45 °C and that adequate clearance is maintained around the enclosure.
Ethernet communication to PLC or SCADA system is lost
Verify the Ethernet cable connection and check the network configuration settings (IP address, subnet mask, gateway) in Windows Network Settings.
Replace the Ethernet cable if damaged. Reconfigure the network settings to match the plant network. If the NIC is not detected in Device Manager, reseat any internal network cards or replace the NIC.
Application software freezes or watchdog resets occur repeatedly
Check the Windows Event Viewer for application errors or memory faults. Monitor CPU and memory utilization during operation.
Update or reinstall the WinCC or HMI runtime software. Increase virtual memory allocation if RAM is insufficient. If hardware faults are indicated, run a memory diagnostic and replace faulty RAM modules.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page



