• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AE30-0CJ0 Mobile Panel 170
    Awaiting product image

    Siemens 6AV7611-0AE30-0CJ0 Mobile Panel 170

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AE30-0CJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AE30-0CJ0 is a Mobile Panel 170, part of the SIMATIC HMI Mobile Panel family from Siemens. This handheld operator panel is designed for flexible, mobile human-machine interface applications where the operator needs to move freely around a machine or plant area. It provides a portable touch-based interface for monitoring and controlling industrial automation systems.

    The Mobile Panel 170 features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA), offering clear visualization of process data and graphics. It is equipped with a membrane keypad with function keys, an enabling button (three-position), and an emergency stop button for safety-critical operations. The panel connects to the control system via a coiled cable with an industrial connector, supporting MPI and PROFIBUS DP communication interfaces. It runs on the WinCC flexible runtime environment and offers 512 KB of user memory for project data.

    The Mobile Panel 170 is widely used in manufacturing, automotive, and machine tool industries where operators need to perform setup, commissioning, or maintenance tasks while moving around large machines or production lines. Its integrated enabling button and emergency stop make it suitable for safety-relevant applications in accordance with machinery safety standards. The rugged, handheld design allows use in demanding industrial environments where fixed HMI panels are impractical.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels (QVGA)
    Display Type STN color
    Display Colors 256 colors
    Communication Interface MPI / PROFIBUS DP
    User Memory 512 KB
    Operating Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Protection Rating IP65 (front)
    Safety Features Three-position enabling button, Emergency stop button
    Series/Product Family SIMATIC HMI Mobile Panel 170
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the Mobile Panel and the connected PLC or controller. The panel cannot establish or maintain a connection.
    Check the cable connection and connector integrity. Verify MPI or PROFIBUS DP address settings on both the panel and the PLC. Ensure the baud rate is correctly configured.
    Event ID: 10001
    Project download error. The project could not be transferred to the panel successfully.
    Check the transfer cable and PC interface settings. Ensure WinCC flexible is configured for the correct communication channel and that the panel is in transfer mode.
    Event ID: 20000
    Tag read error. A configured tag could not be read from the PLC.
    Verify the PLC address and tag address in the WinCC flexible project. Confirm the PLC program is running and the data block or address exists.
    Event ID: 20001
    Tag write error. A value could not be written to the PLC tag.
    Check that the PLC tag address is correct and that the address is not write-protected. Verify communication link integrity.
    Event ID: 40000
    System memory low. Available runtime memory on the panel is insufficient.
    Reduce the complexity of the HMI project, remove unused screens or objects, and reload the project. Consider optimizing graphic objects and tag counts.
    Event ID: 50000
    Enabling button not actuated. The three-position enabling button is not held in the enabled position during a safety-relevant operation.
    Ensure the operator holds the enabling button in the middle (enabled) position. Check the enabling button switch mechanism for mechanical wear or failure.
    Event ID: 60000
    Emergency stop activated. The integrated emergency stop button on the Mobile Panel has been pressed.
    Identify and resolve the cause of the emergency stop activation. Reset the emergency stop button by twisting or pulling as per the panel design, then acknowledge the fault in the control system before resuming operation.

    Frequently Asked Questions

    What communication interfaces does the Mobile Panel 170 (6AV7611-0AE30-0CJ0) support?

    The Mobile Panel 170 supports MPI and PROFIBUS DP communication interfaces, allowing it to connect to Siemens S7-300 and S7-400 PLCs as well as other PROFIBUS-compatible controllers.

    Does the Mobile Panel 170 have an integrated safety enabling button?

    Yes, the panel includes a three-position enabling button that must be held in the middle position to allow motion or safety-relevant commands, in accordance with machinery safety requirements. It also features an integrated emergency stop button.

    What software is used to create projects for the Mobile Panel 170?

    Projects for the Mobile Panel 170 are created using Siemens WinCC flexible software. The project is then downloaded to the panel via the coiled connection cable or a dedicated PC adapter.

    What is the display size and resolution of the 6AV7611-0AE30-0CJ0?

    The display is a 5.7-inch STN color screen with a resolution of 320 x 240 pixels (QVGA) and supports up to 256 colors.

    What is the operating voltage of the Mobile Panel 170?

    The Mobile Panel 170 operates on 24 V DC, supplied through the coiled connection cable from the connection box or junction box.

    Troubleshooting

    Display remains blank after power on

    Check that the 24 V DC supply is present at the connection cable and junction box. Measure voltage at the panel connector. Inspect the coiled cable for damage or broken conductors.

    Replace the coiled connection cable if damaged. Verify the junction box is powered and the supply voltage is within the 24 V DC tolerance range. If the supply is correct and the display remains blank, the panel's internal power supply or display may require repair or replacement.

    Communication error displayed on panel, no connection to PLC

    Verify the MPI or PROFIBUS DP address configured on the panel matches the network configuration. Check the cable and connector for physical damage. Confirm the PLC is in RUN mode and the network is active.

    Correct the MPI or PROFIBUS DP address in the panel settings. Replace the coiled cable or connector if damaged. Ensure the baud rate on the panel matches the network baud rate. Re-download the project if configuration changes are made.

    Enabling button does not allow motion commands

    Test the three-position enabling button by pressing it to the middle position and observing whether the panel acknowledges the enabled state. Check for mechanical wear or sticking of the button mechanism.

    If the enabling button is mechanically worn or faulty, the Mobile Panel requires repair or replacement of the enabling switch assembly. Do not bypass the enabling button, as it is a safety-critical component.

    Project cannot be downloaded to the panel

    Confirm the panel is set to transfer mode. Check the PC adapter and cable connection between the programming PC and the panel or junction box. Verify WinCC flexible project settings match the panel type and firmware version.

    Set the panel to transfer mode via the Start Center menu. Use the correct PC adapter (MPI or PROFIBUS). Ensure the WinCC flexible version is compatible with the panel firmware. Update panel firmware if necessary before re-attempting the download.

    Emergency stop button cannot be reset

    Inspect the emergency stop button for correct mechanical reset (twist-to-release or pull-to-release depending on variant). Check the control system for any latched fault that requires acknowledgment.

    Physically reset the emergency stop button by rotating or pulling the button head as designed. Acknowledge the emergency stop fault in the PLC or safety controller. If the button does not mechanically reset, the button assembly may need replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart