• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AE32-0AE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AE32-0AE0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AE32-0AE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AE32-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial automation environments. The unit combines a high-performance computing platform with a robust industrial enclosure, providing a reliable operator interface for process control and monitoring applications.

    The SIMATIC Panel PC 670 (6AV7611-0AE32-0AE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels and a resistive touchscreen interface. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), enabling integration with a wide range of automation systems and PLCs. The front panel meets IP65 protection rating, making it suitable for use in environments where dust and water ingress are a concern.

    The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, chemical processing, and water treatment industries where a full PC-based HMI solution is required. Its ability to run standard Windows applications alongside SIMATIC WinCC makes it suitable for complex visualization tasks, data logging, and process control. The panel PC form factor allows for direct integration into control cabinets and operator panels, reducing installation space and simplifying system architecture.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interfaces Ethernet (RJ45), USB, RS-232/RS-422/RS-485
    Operating System Windows XP Embedded / Windows 2000
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes and System Events

    Event ID: 1000
    Application error – a software application has encountered an unexpected fault and terminated.
    Check Windows Event Viewer for details. Reinstall or update the affected application. Verify compatibility with the installed OS version.
    Event ID: 6008
    Unexpected system shutdown – the system was shut down uncleanly, possibly due to a power loss or system crash.
    Check the 24 V DC power supply for stability. Inspect for overheating. Review system logs for preceding errors and ensure proper shutdown procedures are followed.
    BIOS POST Error
    Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
    Reseat RAM modules and CompactFlash/hard disk connections. Verify hardware compatibility. Replace faulty components if POST failure persists.
    WinCC Runtime Error
    SIMATIC WinCC runtime has failed to start or has crashed during operation.
    Check WinCC project configuration for errors. Verify license dongle is present and valid. Reinstall WinCC runtime if the issue persists.
    Network Communication Lost
    Ethernet communication to the PLC or network has been interrupted.
    Check Ethernet cable connections and switch/hub status. Verify IP address configuration. Check PLC communication settings and ensure the network interface driver is functioning correctly.
    Touchscreen Not Responding
    The resistive touchscreen is not registering input or is responding inaccurately.
    Recalibrate the touchscreen using the Windows control panel or SIMATIC touchscreen calibration utility. Clean the screen surface. If calibration fails, inspect the touchscreen controller connection internally.
    Storage Device Failure
    The CompactFlash card or hard disk drive is not detected or has reported read/write errors.
    Check the storage device connection. Replace the CompactFlash card or HDD with a compatible unit. Restore the OS and application image from backup.

    Frequently Asked Questions

    What display size and resolution does the 6AV7611-0AE32-0AE0 have?

    The unit features a 12-inch TFT color LCD display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen interface.

    What operating system does the SIMATIC Panel PC 670 6AV7611-0AE32-0AE0 run?

    This Panel PC is designed to run Windows XP Embedded or Windows 2000, and is compatible with SIMATIC WinCC and other Siemens HMI software packages.

    What is the supply voltage for this Panel PC?

    The 6AV7611-0AE32-0AE0 operates on a 24 V DC supply voltage, which is standard for industrial panel PCs in this series.

    What communication interfaces are available on this unit?

    The panel PC provides Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), allowing connection to PLCs, networks, and peripheral devices.

    What is the front panel protection rating of the 6AV7611-0AE32-0AE0?

    The front panel of this unit meets IP65 protection, providing complete protection against dust ingress and resistance to water jets.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the power LED status. Measure voltage at the internal power supply output rails.

    Ensure the 24 V DC supply is within tolerance. Replace the internal power supply if output voltages are absent. If the display backlight is faulty, replace the backlight inverter or the display unit.

    Touchscreen input is inaccurate or unresponsive

    Determine whether the issue is a calibration problem or a hardware fault by attempting recalibration through the Windows control panel.

    Recalibrate the touchscreen using the SIMATIC calibration tool or Windows Pointer Device settings. If recalibration does not resolve the issue, inspect the touchscreen ribbon cable connection and replace the touchscreen assembly if damaged.

    System fails to boot or continuously restarts

    Observe the boot sequence for BIOS POST errors. Check if the CompactFlash card or hard disk is detected in BIOS. Listen for beep codes during POST.

    Reseat the storage device and RAM. Replace the CompactFlash card or HDD if not detected. Restore the operating system image from a backup. If the issue persists, the motherboard may require replacement.

    Loss of communication with PLC or SCADA system

    Check Ethernet cable integrity and verify the IP address configuration in Windows network settings. Ping the PLC from the Panel PC to test connectivity.

    Replace the Ethernet cable if faulty. Reconfigure the IP address and subnet mask to match the network. Update or reinstall the network interface driver. Verify PLC communication settings in the WinCC project.

    WinCC runtime does not start or shows license error

    Check for the presence of the SIMATIC software license dongle on the USB port. Review the WinCC error log for specific fault messages.

    Ensure the correct license dongle is connected. Transfer the license using the Automation License Manager if the license is stored incorrectly. Reinstall WinCC runtime if the software installation is corrupted.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart