Siemens 6AV7611-0AE30-0AJ0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE30-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. The unit combines a built-in display with a full PC architecture, enabling it to run standard PC operating systems and SCADA/HMI software packages.
The SIMATIC Panel PC 670 (6AV7611-0AE30-0AJ0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, providing compatibility with standard industrial software. The unit offers multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is designed with a fanless or low-noise cooling concept suited for continuous industrial operation. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a robust, PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its compatibility with Siemens WinCC and other SCADA software makes it a practical choice for visualization and data acquisition tasks in both standalone and networked control architectures.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Processor | Intel Celeron |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front panel) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup error or boot failure detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration. Replace storage media if corrupted. - Event ID: 101
- Hardware component not recognized or driver initialization failed during startup.
Check device manager for missing or failed drivers. Reinstall drivers or replace the faulty hardware component. - Event ID: 200
- Ethernet communication interface error or network connectivity lost.
Check Ethernet cable connections and network switch. Verify IP address configuration and network settings in the operating system. - Event ID: 201
- USB device communication error or USB port failure.
Disconnect and reconnect the USB device. Test with an alternative USB port. Check USB controller status in device manager. - Event ID: 300
- Touch screen calibration error or touch input not responding correctly.
Recalibrate the touch screen using the calibration utility in the control panel. If persistent, check touch controller connection or replace touch screen overlay. - Event ID: 400
- Internal temperature warning — operating temperature threshold exceeded.
Check ambient temperature and ensure adequate ventilation around the panel PC. Clean air vents and verify cooling system operation. - Event ID: 500
- Power supply voltage out of tolerance — 24 V DC supply outside acceptable range.
Measure the 24 V DC supply voltage at the power connector. Ensure the supply is within the specified tolerance range and check wiring connections. - Event ID: 600
- Hard disk or storage media read/write error detected.
Run disk diagnostics utility. Back up data immediately. Replace the hard disk or CompactFlash card if errors persist.
Frequently Asked Questions
What is the display size and resolution of the 6AV7611-0AE30-0AJ0?
The SIMATIC Panel PC 670 (6AV7611-0AE30-0AJ0) features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
What operating voltage does the 6AV7611-0AE30-0AJ0 require?
This Panel PC operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC 670 series devices.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces, enabling connectivity to PLCs, networks, and peripheral devices.
Is the 6AV7611-0AE30-0AJ0 compatible with Siemens WinCC software?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and other standard HMI and SCADA software packages that run on Windows operating systems.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7611-0AE30-0AJ0 meets IP65 protection rating, providing protection against dust and low-pressure water jets.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator is active. Check internal fuse if accessible.
Ensure the 24 V DC supply is within tolerance. Replace the internal fuse if blown. If the backlight has failed, replace the backlight unit or the display assembly.
Touch screen does not respond or responds inaccurately
Determine whether the issue is a calibration problem or a hardware failure by testing touch response across the entire screen surface.
Recalibrate the touch screen using the Windows control panel calibration utility. If calibration does not resolve the issue, inspect the touch screen connector and replace the touch screen overlay if damaged.
Panel PC fails to boot or continuously restarts
Observe the boot sequence for error messages. Check the hard disk or CompactFlash storage media for errors using diagnostic tools booted from external media.
Run disk diagnostics and repair or replace the storage media as needed. Reinstall the operating system if the file system is corrupted. Check RAM modules for faults.
Ethernet communication not working
Check the Ethernet cable connection and verify the link LED on the RJ45 port is active. Confirm IP address settings in the operating system network configuration.
Replace the Ethernet cable if faulty. Reconfigure the IP address and subnet mask settings. Update or reinstall the network adapter driver if the interface is not recognized.
Panel PC overheating or shutting down unexpectedly
Monitor the internal temperature using system monitoring software. Check that ambient temperature is within the 0 to 50 degrees Celsius operating range and that ventilation openings are not blocked.
Clean dust from ventilation openings and ensure adequate clearance around the unit. Verify that the installation environment does not exceed the maximum ambient temperature specification.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page