Siemens 6AV7611-0AE30-0BE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE30-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens as part of its industrial computing and HMI portfolio. This unit is a high-performance industrial panel PC designed for demanding visualization and control tasks in automation environments. It integrates computing power and a flat-panel display into a single compact unit suitable for direct panel mounting.
The SIMATIC Panel PC 670 6AV7611-0AE30-0BE0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a resistive touchscreen for operator input. The unit runs on a Windows-based operating system and is built around an x86-compatible processor architecture, providing sufficient computing power for SCADA, visualization, and data acquisition applications. It supports standard communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), enabling integration with PLCs, field devices, and plant networks. The robust industrial housing is designed to meet IP65 protection on the front panel, making it resistant to dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, food and beverage, and process industries where a combined HMI and computing platform is required. It is commonly deployed as a visualization station for SIMATIC WinCC or other SCADA software, as well as for machine-level control and monitoring. Its panel-mount design and industrial-grade construction make it suitable for integration into control cabinets and operator stations in harsh industrial environments.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interfaces | Ethernet RJ45, USB, RS-232/RS-422/RS-485 |
| Operating System | Windows XP Embedded / Windows 2000 |
| Mounting | Panel mounting |
| Series | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Watchdog timeout triggered, indicating the application or OS has become unresponsive.
Restart the Panel PC. Investigate application software for infinite loops or resource exhaustion. Update or reinstall the HMI application. - Event ID: 300
- Fan failure or thermal warning detected; internal temperature exceeding threshold.
Check and clean cooling fan and ventilation slots. Verify ambient temperature is within specification. Replace fan module if defective. - Event ID: 400
- Ethernet communication failure; network interface not detected or link down.
Check Ethernet cable and switch port. Verify IP address configuration. Reinstall network adapter drivers if necessary. - Event ID: 500
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen using the Windows calibration utility. Clean the screen surface. Replace touchscreen controller if calibration fails repeatedly. - Event ID: 600
- Hard disk or storage media error detected; read/write failure on system drive.
Run disk diagnostics. Back up data immediately. Replace the hard disk or CompactFlash card and restore the system image. - Event ID: 700
- Power supply voltage out of range; 24 V DC supply below or above acceptable limits.
Measure the 24 V DC supply voltage at the input connector. Ensure supply is within tolerance. Check wiring and power supply unit. - Event ID: 800
- USB device error; connected USB peripheral not recognized or causing system instability.
Disconnect the USB device and restart. Use only approved USB devices. Check USB port for physical damage.
Frequently Asked Questions
What is the display size and resolution of the 6AV7611-0AE30-0BE0?
The 6AV7611-0AE30-0BE0 features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
What operating system does the SIMATIC Panel PC 670 run?
This Panel PC is compatible with Windows XP Embedded and Windows 2000, supporting standard industrial HMI and SCADA software such as SIMATIC WinCC.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485) for connectivity to PLCs, networks, and peripheral devices.
What is the front panel protection rating of the 6AV7611-0AE30-0BE0?
The front panel of this unit meets IP65 protection, providing resistance against dust ingress and water jets.
What is the supply voltage for the SIMATIC Panel PC 670?
The unit operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs in this series.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the input connector. Verify the power LED status. Measure voltage at the internal power supply output to the display backlight.
Ensure the 24 V DC supply is within tolerance. Replace the backlight inverter or display unit if the supply is confirmed good and the screen remains dark.
Touchscreen does not respond or registers incorrect touch positions
Attempt to recalibrate the touchscreen via the Windows control panel. Check for physical damage or contamination on the screen surface.
Perform a full touchscreen recalibration. Clean the screen with a soft cloth. If the issue persists, replace the touchscreen overlay or touchscreen controller board.
Panel PC fails to boot or continuously restarts
Check the storage media (hard disk or CompactFlash card) for errors using diagnostic tools. Verify BIOS settings and check for POST error messages on screen.
Replace the storage media and restore the system image from a backup. If the issue is hardware-related, reseat RAM modules and check for loose internal connections.
Ethernet communication is not established
Verify the Ethernet cable connection and check the link LED on the RJ45 port. Confirm IP address settings in Windows network configuration.
Replace the Ethernet cable and verify switch port operation. Reconfigure the IP address settings. Reinstall the network adapter driver if the interface is not detected.
System runs slowly or HMI application freezes
Check CPU and memory utilization in Windows Task Manager. Identify any background processes consuming excessive resources. Check available disk space on the system drive.
Close unnecessary background applications. Free up disk space or replace the storage media. If RAM is insufficient, consider upgrading memory if the hardware supports it.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page