Siemens 6AV7611-0AE10-0AE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE10-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7611-0AE10-0AE0) features a 10.4-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), providing clear visualization of process data. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit includes standard PC interfaces such as USB, serial (RS-232), parallel, and Ethernet ports, enabling flexible integration into existing automation networks. The fanless or low-noise design and industrial-grade components ensure reliable operation in harsh industrial conditions.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, chemical processing, and food and beverage industries where robust panel-mounted visualization is required. It is suitable for installation in control cabinets and operator panels on the production floor, providing operators with real-time process data and control capabilities. Its compatibility with Siemens SIMATIC software and standard PC peripherals makes it a versatile platform for both standalone HMI applications and networked SCADA systems.
Technical Specifications
| Display Size | 10.4 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Input/Operating Voltage | 24 V DC |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Communication Interface | Ethernet (RJ45), RS-232, USB, Parallel |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Windows XP / Windows 2000 |
Common Error Codes & System Events
- Event ID: 1000
- Application error – an application process has terminated unexpectedly, typically related to WinCC Runtime or a visualization application.
Check the Windows Event Viewer for details. Restart the affected application. If recurring, reinstall the HMI software or check for software conflicts. - Event ID: 7034
- A service terminated unexpectedly. This may relate to a SIMATIC or system service that has crashed.
Identify the affected service in Windows Event Viewer. Restart the service manually or configure automatic recovery. Check for software or driver conflicts. - BIOS POST Error
- Hardware initialization failure during power-on self-test, which may indicate a memory, CPU, or hardware fault.
Check seating of RAM modules and internal connections. If the error persists, replace the faulty hardware component or contact Siemens service. - WinCC Runtime Error
- WinCC Runtime fails to start or crashes, often due to a corrupted project file or licensing issue.
Verify the WinCC license is valid and installed correctly. Reload or restore the WinCC project from backup. Reinstall WinCC Runtime if necessary. - Network Communication Error
- Loss of communication between the Panel PC and the PLC or network, resulting in no data updates on the HMI screen.
Check Ethernet cable connections and network switch status. Verify IP address configuration and firewall settings. Confirm the PLC is online and the communication driver is correctly configured. - Hard Disk Error
- The internal hard disk or CompactFlash storage device has failed or is reporting errors, causing system instability or failure to boot.
Run a disk check utility (chkdsk) to identify and repair file system errors. Back up data immediately. Replace the hard disk or CompactFlash card if hardware failure is confirmed. - Watchdog Timeout
- The system watchdog has triggered a reset due to the operating system or application becoming unresponsive.
Investigate the cause of the system hang, such as a runaway process or memory leak. Update drivers and software. If hardware-related, check CPU and memory health.
Frequently Asked Questions
What display size and resolution does the 6AV7611-0AE10-0AE0 have?
The unit features a 10.4-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), suitable for clear process visualization.
What operating system does the SIMATIC Panel PC 670 (6AV7611-0AE10-0AE0) support?
This Panel PC supports Windows 2000 and Windows XP operating systems, and is compatible with SIMATIC WinCC and other Siemens HMI software packages.
What communication interfaces are available on this Panel PC?
The 6AV7611-0AE10-0AE0 provides Ethernet (RJ45), RS-232 serial, USB, and parallel interfaces for connectivity to PLCs, networks, and peripherals.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets for use in industrial environments.
Is this Panel PC compatible with SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and other Siemens visualization software, making it directly compatible with Siemens automation systems.
Troubleshooting
Panel PC does not boot or display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED is illuminated. Listen for POST beep codes that may indicate a hardware fault.
Ensure the 24 V DC supply is within tolerance. Reseat RAM modules and internal connectors. If the hard disk or CompactFlash card has failed, replace it. If the internal power supply board is faulty, replace the power supply module.
Touchscreen does not respond or is inaccurate
Check if the touchscreen is recognized in Windows Device Manager. Determine whether the issue is a calibration problem or a hardware failure by testing with a USB mouse.
Recalibrate the touchscreen using the Windows calibration utility. If the touchscreen is not recognized, reinstall the touchscreen driver. If the touchscreen hardware is damaged, replace the touch panel assembly.
WinCC Runtime does not start or displays a license error
Check the WinCC license status using the Siemens Automation License Manager. Verify that the license dongle or software license is correctly installed and recognized.
Reinstall or transfer the WinCC license using the Automation License Manager. If using a hardware dongle, ensure it is firmly connected to a USB port. Contact Siemens support if the license cannot be recovered.
Loss of communication with PLC or network devices
Verify the Ethernet cable connection and check the link LED on the RJ45 port. Ping the PLC IP address from the Panel PC to test network connectivity. Check the WinCC communication driver configuration.
Replace the Ethernet cable if faulty. Verify the IP address, subnet mask, and gateway settings on the Panel PC. Reconfigure the WinCC communication driver with the correct PLC connection parameters.
System runs slowly or freezes during operation
Check CPU and memory usage in Windows Task Manager. Identify any processes consuming excessive resources. Check the hard disk for errors using chkdsk.
Close unnecessary background applications. Run a disk check and defragmentation on the hard drive. If the hard disk is failing, replace it with a compatible unit. Consider increasing RAM if the system is consistently under high memory load.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page