• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AE10-0AF0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AE10-0AF0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AE10-0AF0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AE10-0AF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling advanced process visualization, data acquisition, and control functions within a single integrated device.

    The SIMATIC Panel PC 670 (6AV7611-0AE10-0AF0) features a 10.4-inch TFT color display with a touch-sensitive screen for operator interaction. It is built around an industrial-grade processor platform running Microsoft Windows, providing compatibility with SIMATIC WinCC and other Siemens SCADA and HMI software packages. The unit includes standard PC interfaces such as USB, Ethernet, and serial ports, and is designed for front-panel mounting with an IP65-rated front face for protection against dust and water ingress. Onboard memory and storage options support complex visualization projects and local data logging.

    The SIMATIC Panel PC 670 is widely deployed in manufacturing, process industries, and machine automation where a full PC-based HMI solution is required. It is suitable for applications in the automotive, chemical, food and beverage, and pharmaceutical industries, where operators need a robust, panel-integrated computing platform for supervisory control and data visualization. Its fanless or low-maintenance design options make it appropriate for environments where reliability and reduced maintenance intervals are critical.

    Technical Specifications

    Display Size 10.4 inch
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Display Colors 256 colors
    Input Voltage 24 V DC
    IP Rating (Front) IP65
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232
    Operating System Microsoft Windows XP Embedded
    Series/Product Family SIMATIC Panel PC 670
    Mounting Panel mounting (front flush)
    Certifications CE, UL

    Common Error Codes and System Events

    Event ID: 100
    System startup failure or BIOS POST error during boot sequence.
    Check power supply voltage at 24 V DC input. Verify all internal connections and reseat RAM modules. If fault persists, replace the motherboard or contact Siemens service.
    Event ID: 1000
    Application crash or unexpected software termination reported by Windows Event Log.
    Review Windows Event Viewer for detailed error information. Reinstall or repair the HMI application software (e.g., WinCC). Check for corrupted system files using Windows repair tools.
    Event ID: 6008
    Unexpected system shutdown recorded by the operating system.
    Check for power supply instability or undervoltage at the 24 V DC input. Inspect cooling and ensure operating temperature is within specification. Review event logs for preceding errors.
    BIOS POST Beep Error
    Hardware fault detected during Power-On Self-Test, indicated by audible beep codes.
    Identify beep code pattern and cross-reference with motherboard documentation. Common causes include failed RAM or CPU. Reseat or replace faulty hardware components.
    WinCC Runtime Error
    SIMATIC WinCC runtime application fails to start or terminates unexpectedly.
    Verify WinCC license dongle is present and recognized. Reinstall WinCC runtime software. Check project file integrity and ensure sufficient disk space is available.
    Network Communication Error
    Loss of communication between Panel PC and PLC or network devices.
    Check Ethernet cable and connection at RJ45 port. Verify IP address configuration and subnet settings. Test network connectivity using ping command. Inspect PLC communication settings.
    Hard Disk Fault
    Operating system reports disk read/write errors or the storage device is not detected.
    Run disk diagnostics using Windows tools (chkdsk). Back up project data immediately. Replace the CompactFlash card or hard disk drive if hardware failure is confirmed.
    Touchscreen Not Responding
    Touch input is not registered or is inaccurate on the display surface.
    Recalibrate the touchscreen using the Windows control panel calibration utility. Clean the screen surface. If calibration fails, inspect the touch controller connection or replace the touchscreen assembly.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7611-0AE10-0AF0?

    The unit operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.

    What HMI software is compatible with the SIMATIC Panel PC 670?

    The Panel PC 670 is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other Windows-based SCADA and visualization software. It runs Microsoft Windows XP Embedded as its operating system.

    What is the front panel protection rating of this Panel PC?

    The front panel of the 6AV7611-0AE10-0AF0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial panel installations.

    Can the SIMATIC Panel PC 670 communicate directly with Siemens S7 PLCs?

    Yes, the Panel PC 670 can communicate with Siemens S7-300 and S7-400 PLCs via Ethernet using PROFINET or S7 protocol, as well as through MPI or PROFIBUS adapters when appropriate interface cards are installed.

    What display size does the 6AV7611-0AE10-0AF0 feature?

    This unit is equipped with a 10.4-inch TFT color LCD display with resistive touchscreen input.

    Troubleshooting

    Panel PC does not power on after applying 24 V DC supply

    Measure the supply voltage at the DC input connector to confirm it is within the 24 V DC tolerance range. Check the internal fuse and inspect the power supply module for visible damage.

    Replace the internal fuse if blown, using the correct rating specified in the hardware manual. If the power supply module is faulty, replace it. Ensure the external power source is stable and correctly wired.

    Display is blank or shows no image after power on

    Confirm the unit is powered (check status LEDs if present). Connect an external monitor via the VGA port if available to determine whether the issue is with the display or the PC itself. Check display cable connections internally.

    If the external monitor shows output, the internal display or its cable connection is faulty — reseat or replace the display cable. If no output is present on either display, the graphics adapter or motherboard may require replacement.

    Touchscreen input is inaccurate or unresponsive

    Attempt touchscreen recalibration through the Windows Control Panel. Inspect the screen surface for contamination or physical damage. Check the USB or internal connection of the touch controller.

    Recalibrate the touchscreen using the Windows calibration utility. Clean the screen with a soft, dry cloth. If recalibration does not resolve the issue, replace the touchscreen assembly or touch controller board.

    System boots slowly or freezes during Windows startup

    Check available storage space on the CompactFlash card or hard disk. Review Windows Event Viewer for startup errors. Test RAM modules by reseating them and running a memory diagnostic tool.

    Free up disk space by removing unnecessary files or archiving old project data. If a hardware fault is identified in RAM or storage, replace the faulty component. Reinstall the operating system if system files are corrupted.

    Loss of communication with connected PLC or network devices

    Verify the Ethernet cable is securely connected and test with a known-good cable. Check the IP address and subnet mask configuration in Windows Network Settings. Ping the PLC from the Panel PC to test basic connectivity.

    Correct any IP address conflicts or misconfiguration. Replace the Ethernet cable if defective. If the onboard Ethernet port is faulty, install a compatible USB-to-Ethernet adapter or replace the network interface component.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart