• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AB30-0BJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AB30-0BJ0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AB30-0BJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AB30-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, providing a compact and robust solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7611-0AB30-0BJ0) features a 10.4-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an industrial-grade processor platform and runs Microsoft Windows operating systems, enabling compatibility with SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB ports, serial (RS-232) interfaces, and Ethernet connectivity, and is designed for front-panel mounting with an IP65 protection rating on the front face.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a robust, panel-integrated PC-based HMI is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its fanless or low-maintenance design options and industrial-grade components make it appropriate for continuous operation in harsh industrial environments.

    Technical Specifications

    Display Size 10.4 inch
    Display Type TFT Color LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Touch Technology Resistive Touch Screen
    Input Voltage 24 V DC
    Front Protection Rating IP65
    Rear Protection Rating IP20
    Communication Interface Ethernet (RJ45), RS-232, USB
    Operating System Microsoft Windows XP / Windows 2000
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Mounting Panel mounting (front flush)
    Series SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly, possibly due to a corrupted system partition or failed storage device.
    Check the CompactFlash card or hard disk for errors. Restore the system image from backup using the recovery partition or external media.
    Event ID: 1000
    Application fault — a software application such as WinCC Runtime has crashed unexpectedly.
    Restart the application. Check the Windows Event Viewer for detailed error logs. Reinstall the HMI software if the fault persists.
    Event ID: 7000
    Service failed to start — a required Windows service did not start during boot, which may prevent HMI communication or display functions.
    Check the Windows Event Viewer under System logs. Verify service dependencies and restart the affected service manually or via Services management console.
    Communication Error
    Loss of communication between the Panel PC and the connected PLC or automation controller via Ethernet or serial interface.
    Verify network cable connections and IP address configuration. Check firewall settings and ensure the PLC communication driver is correctly configured in the HMI project.
    Watchdog Timeout
    The system watchdog has triggered due to the operating system or application becoming unresponsive.
    Perform a controlled restart of the Panel PC. Investigate CPU load and memory usage. Reduce background processes or upgrade RAM if resources are insufficient.
    Temperature Warning
    Internal temperature of the Panel PC has exceeded the recommended operating threshold.
    Check that ventilation slots are not obstructed. Verify ambient temperature is within the 0 °C to +50 °C operating range. Clean any dust from cooling surfaces.
    Display Backlight Failure
    The TFT display backlight has failed or degraded significantly, resulting in a dim or blank screen.
    Replace the backlight inverter board or the display assembly. Verify the display power connector is securely seated on the motherboard.
    Storage Device Error
    The CompactFlash card or hard disk drive is not detected or is reporting read/write errors.
    Reseat the CompactFlash card or check HDD connections. Replace the storage device if errors persist and restore the system image from a backup.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7611-0AB30-0BJ0?

    The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices.

    What display size and resolution does this Panel PC have?

    The 6AV7611-0AB30-0BJ0 features a 10.4-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).

    What HMI software is compatible with this Panel PC?

    The SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other Windows-based SCADA and HMI software packages, as it runs a standard Microsoft Windows operating system.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7611-0AB30-0BJ0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for panel-flush installation in industrial enclosures.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), RS-232 serial, and USB interfaces for connectivity to PLCs, networks, and peripheral devices.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the backlight inverter is functioning by listening for a faint high-frequency tone. Measure voltage at the display connector.

    Confirm the 24 V DC supply is within tolerance. If the backlight has failed, replace the inverter board or the display assembly. If the unit does not power on at all, inspect internal fuses and the power supply board.

    Touch screen does not respond or responds inaccurately

    Check if the touch controller is recognized in Windows Device Manager. Attempt to recalibrate the touch screen using the Windows calibration utility. Inspect the touch screen ribbon cable connection.

    Recalibrate the touch screen via the Windows Control Panel touch settings. If the touch layer is physically damaged or the ribbon cable is loose, reseat or replace the touch screen assembly.

    Panel PC fails to boot into Windows

    Observe the boot sequence for BIOS POST errors. Check whether the CompactFlash card or hard disk is detected in the BIOS. Attempt to boot from an external USB device to isolate the storage device as the fault source.

    Restore the system image to the CompactFlash card or hard disk using Siemens recovery media. Replace the storage device if it is not detected or shows persistent errors.

    Loss of communication with PLC

    Verify the Ethernet cable is connected and the link LED on the RJ45 port is active. Check the IP address configuration in Windows and confirm it matches the HMI project settings. Use ping to test network connectivity.

    Correct any IP address conflicts or misconfigurations. Replace the Ethernet cable if faulty. Reinstall the communication driver or reconfigure the HMI project connection settings if the network layer is functional but communication still fails.

    Unit overheating or shutting down unexpectedly

    Check the ambient temperature around the Panel PC installation. Inspect ventilation openings for dust blockage. Monitor CPU and system temperature using a diagnostic utility within Windows.

    Clean ventilation surfaces and ensure the installation environment is within the 0 °C to +50 °C operating range. Ensure the panel cutout provides adequate clearance for heat dissipation. If thermal paste on the processor has degraded, reapply and reseat the heatsink.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart