Siemens 6AV7611-0AB30-0CE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AB30-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7611-0AB30-0CE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors, providing clear visualization of process data. It is equipped with standard PC interfaces including USB, serial (COM), and parallel ports, as well as an Ethernet interface for network connectivity and integration with SIMATIC WinCC or other SCADA software. The unit runs on a Windows-based operating system and is built with an aluminum front panel rated to IP65, ensuring protection against dust and water ingress from the front side. It operates on a 24 V DC supply voltage and is designed for panel mounting in control cabinet doors.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, chemical processing, and water treatment industries where a reliable, PC-based HMI solution is required. Its compatibility with Siemens SIMATIC software such as WinCC flexible and ProTool makes it suitable for integration into existing SIMATIC automation architectures. The rugged industrial design and wide operating temperature range make it appropriate for use in factory floor environments with variable ambient conditions.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 64,000 colors |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM), Parallel |
| Operating System | Windows XP Embedded / Windows 2000 |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the integrity of the OS installation. Restore or reinstall the operating system image using the recovery partition or a backup image. - Event ID: 101
- Hardware configuration mismatch detected — installed hardware does not match the stored configuration profile.
Enter the BIOS setup and verify hardware settings. Reset BIOS to default values if necessary and reconfigure. - Event ID: 102
- Watchdog timeout — the system watchdog timer triggered a reset due to application or OS hang.
Investigate the running application for infinite loops or deadlocks. Update or reinstall the HMI runtime software (e.g., WinCC). - Communication Error
- Loss of communication between the Panel PC and the connected PLC or automation controller.
Check Ethernet or serial cable connections. Verify IP address settings and network configuration. Confirm PLC is online and reachable. - Display Backlight Failure
- The TFT display backlight has failed or is at end of life, resulting in a dark or dim screen.
Replace the CCFL backlight lamp or the inverter board. Contact Siemens service or a qualified repair center for display module replacement. - Fan Failure Warning
- The internal cooling fan has stopped or is running below the required speed threshold.
Clean the fan and ventilation slots of dust and debris. If the fan does not recover, replace the internal cooling fan unit. - Hard Disk Error
- The internal hard disk drive or CompactFlash storage device has reported a read/write error or is not detected.
Run a disk diagnostic utility. Back up data immediately if possible. Replace the HDD or CompactFlash card and restore the OS image. - Temperature Warning
- The internal temperature of the Panel PC has exceeded the permissible operating threshold.
Ensure ambient temperature is within the 0–45 °C operating range. Check that ventilation clearances are maintained and the cooling fan is operational.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AB30-0CE0?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices.
What HMI software is compatible with this Panel PC?
The 6AV7611-0AB30-0CE0 is compatible with Siemens SIMATIC WinCC, WinCC flexible, and ProTool visualization software running under Windows XP Embedded or Windows 2000.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 is rated to IP65, providing full protection against dust and water jets from the front side.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, RS-232 serial (COM) ports, and a parallel port for peripheral and network connectivity.
Can this Panel PC be used as a replacement for older SIMATIC Panel PC 670 variants?
Yes, the 6AV7611-0AB30-0CE0 is part of the SIMATIC Panel PC 670 family and can generally replace earlier variants of the same series, provided the software configuration and interface requirements are compatible.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify the backlight inverter is functioning and the display cable is securely connected internally.
Restore correct 24 V DC supply if absent. If supply is correct, replace the backlight inverter board or CCFL lamp. If the display panel itself is faulty, replace the TFT display module.
Panel PC does not boot and shows no OS activity
Check whether the BIOS POST screen appears. If not, suspect a hardware failure (RAM, CPU board, or power supply). If POST appears but OS does not load, suspect a corrupted OS or failed storage device.
Reseat RAM modules and internal connectors. Restore the operating system from the recovery partition or a backup image. Replace the HDD or CompactFlash storage card if it is not detected.
Touchscreen does not respond or is inaccurate
Verify that the touchscreen controller driver is correctly installed in the operating system. Check the internal ribbon cable connection between the touch panel and the controller board.
Recalibrate the touchscreen using the calibration utility in the operating system. Reinstall the touchscreen driver if necessary. If the touch panel is physically damaged, replace the touch overlay.
Loss of communication with PLC or network devices
Check the Ethernet cable and RJ45 connector for damage. Verify the IP address configuration of the Panel PC matches the network settings. Use a ping test to confirm network reachability.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings in Windows network settings. If the onboard Ethernet port is faulty, install a compatible USB-to-Ethernet adapter as a temporary measure.
System reboots unexpectedly or watchdog resets occur
Check the event log in Windows for watchdog timeout or application crash entries. Monitor internal temperature to rule out thermal shutdown. Inspect the power supply for voltage instability.
Ensure the 24 V DC supply is stable and within tolerance. Verify ambient temperature is within the 0–45 °C operating range. Update or reinstall the HMI runtime application to resolve software-related watchdog triggers.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page