Siemens 6AV7611-0AA30-0AH0 Mobile Panel 170
€ 1.770,00
The Siemens 6AV7611-0AA30-0AH0 is a Mobile Panel 170, part of the SIMATIC Mobile Panel series from Siemens. This handheld HMI device is designed for flexible, portable operator control and monitoring of industrial machinery and processes. It provides a compact, rugged interface that can be carried by operators directly to the point of operation, enabling local control without fixed panel installations.
The Mobile Panel 170 features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA), offering clear visualization of process data and operator screens. It includes a membrane keypad with function keys, numeric keys, and a built-in enabling button (dead man's switch) for safe operation in hazardous areas. The unit communicates via PROFIBUS DP interface and supports MPI protocol, allowing direct integration with Siemens S7-300 and S7-400 PLCs. It operates on 24 V DC supply power and is built to withstand industrial environments with an IP65 protection rating on the front face.
The Mobile Panel 170 is widely used in manufacturing, automotive assembly, machine tool, and process industries where operators need to move freely around machinery during setup, maintenance, or commissioning tasks. Its integrated enabling switch makes it suitable for applications requiring safe manual intervention near moving machine parts, in compliance with machinery safety directives. The device is particularly common in applications governed by IEC 60204-1 safety requirements for operator control stations.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Type | STN color LCD |
| Display Colors | 256 colors |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | PROFIBUS DP / MPI |
| IP/Protection Rating | IP65 (front) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Safety Features | Integrated enabling button (3-position dead man's switch), Emergency stop button |
| Keypad | Membrane keypad with function keys and numeric keys |
| Series/Product Family | SIMATIC Mobile Panel |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the Mobile Panel and the connected PLC or PROFIBUS network. The panel cannot establish or maintain a connection.
Check PROFIBUS DP cable connections and termination resistors. Verify the PLC is in RUN mode and the configured MPI/PROFIBUS address matches the panel settings. - Event ID: 10001
- Configuration error detected. The project loaded on the panel does not match the connected controller or the panel hardware configuration.
Re-download the correct WinCC flexible project to the panel using a PC with WinCC flexible engineering software. Verify PLC type and address settings in the project. - Event ID: 20000
- Internal device error or system fault detected on the Mobile Panel.
Perform a power cycle on the device. If the error persists, perform a factory reset and reload the project. Contact Siemens technical support if the fault recurs. - Event ID: 40000
- Enabling button (dead man's switch) fault. The enabling switch signal is not being correctly detected or has been held in the enabled position for an extended period.
Release and re-engage the enabling button. Inspect the enabling switch for mechanical damage or contact wear. Replace the enabling switch assembly if faulty. - Event ID: 50000
- Emergency stop button activated. The integrated E-stop has been pressed, halting machine operation.
Identify and resolve the cause of the emergency stop condition. Twist and release the E-stop button, then acknowledge the fault on the panel or PLC before restarting the machine. - Event ID: 60000
- Panel operating voltage out of range. The 24 V DC supply voltage has dropped below or exceeded the acceptable threshold.
Measure the supply voltage at the panel connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance. Check cable integrity and connector contacts. - Event ID: 70000
- Project transfer error. A project download from the engineering PC to the Mobile Panel was interrupted or failed.
Check the USB or PROFIBUS transfer cable connection. Restart the transfer in WinCC flexible. Ensure the panel is in transfer mode before initiating the download.
Frequently Asked Questions
Which PLCs are compatible with the Mobile Panel 170 (6AV7611-0AA30-0AH0)?
The Mobile Panel 170 is compatible with Siemens S7-300 and S7-400 PLCs via MPI or PROFIBUS DP communication. It can also communicate with S7-200 PLCs using the appropriate protocol configuration.
What engineering software is required to configure this Mobile Panel?
The Mobile Panel 170 is configured using Siemens WinCC flexible engineering software. Projects are created on a PC and downloaded to the panel via a transfer cable or PROFIBUS connection.
What is the function of the enabling button on this device?
The enabling button is a 3-position dead man's switch that must be held in the middle position to allow machine motion commands from the panel. Releasing or fully pressing the button removes the enable signal, stopping machine movement for safety purposes.
What is the display size and type on the 6AV7611-0AA30-0AH0?
The device features a 5.7-inch STN color LCD display with a resolution of 320 x 240 pixels (QVGA), capable of displaying 256 colors.
What is the IP protection rating of the Mobile Panel 170?
The front face of the Mobile Panel 170 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for typical industrial environments.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify the supply is within the specified tolerance and that the connector is fully seated.
Restore correct 24 V DC supply voltage. If voltage is correct but display remains blank, inspect the internal backlight or display assembly for failure and arrange repair or replacement of the display unit.
Panel cannot establish communication with the PLC
Verify the PROFIBUS DP or MPI cable is correctly connected and terminated at both ends. Check that the bus address configured in the panel project matches the physical address set on the panel and PLC.
Correct any address mismatches in the WinCC flexible project and re-download. Replace damaged PROFIBUS cables or connectors. Ensure termination resistors are active only at the two physical ends of the bus segment.
Enabling button does not activate machine motion
Test the enabling switch by monitoring the enable signal at the PLC input. Check for mechanical wear or damage to the 3-position switch mechanism. Verify the safety circuit wiring connected to the enabling output.
If the switch mechanism is worn or damaged, replace the enabling switch assembly. Verify the safety relay or PLC safety input is correctly wired and configured to respond to the enabling button signal.
Project transfer from PC to panel fails or times out
Check the transfer cable connection between the PC and the Mobile Panel. Confirm the panel is set to transfer mode via the panel's start center menu. Verify WinCC flexible project settings match the panel type and firmware version.
Use a known-good transfer cable. Set the panel to transfer mode before initiating the download. If firmware mismatch is suspected, update the panel firmware using the Siemens ProSave tool before re-attempting the project transfer.
Touchscreen or keypad inputs are not responding correctly
Check for physical damage to the membrane keypad or display surface. Perform a keypad test from the panel's system settings menu to identify which keys are unresponsive.
Clean the keypad surface and inspect for contamination or mechanical damage. If individual keys are permanently unresponsive, the keypad membrane assembly requires replacement. For persistent issues, return the unit for professional repair.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B